35 resultados para Indirect immunofluorescent antibody test

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study determined whether cutaneous antibodies were present in excised skin explants of grass carp, Ctenopharyngodon idella, immune to Scophthalmus maximus rhabdovirus (SMRV). Culture fluid from immune skin explants were assayed by indirect enzyme-linked immunosorbent assay (iELISA), Western blot, indirect immunofluorescent assay (IFA) and flow cytometry (FCM). iELISA showed that cutaneous antibody titres were much lower (1:12) than antiserum titres (1:1458) from intraperitoneally immunized grass carp. The phosphoprotein and matrix protein antigens of purified SMRV proteins were recognized by cutaneous antibodies from skin culture fluid using Western blot. The skin culture fluid produced staining signals in viral assembly sites and cytoplasm of SMRV-infected epithelioma papulosum cyprini (EPC) cells by IFA. FCM showed that 4.39% SMRV-infected EPC cells were detected, while non-specific reaction was seen in 2% of control cells. This is the first description of cutaneous antibodies against SMRV in grass carp.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The humoral immune responses of grouper Epinephelus akaara to a natural infection with Glugea epinephelusis was studied by ELISA utilizing intact mature spores as the coated antigen. Results showed that a specific humoral immune response was elicited, but the intensity of infection (in terms of the number of cysts) was not related to the antibody level in naturally infected hosts. The differences in the antigenicity of intact mature spores and soluble spore proteins derived from cracked mature spores were also analyzed. Results suggested that similar antigen epitopes existed between the 2 groups. Additionally, antigen component patterns and the distribution of antigen with immunogenicity were investigated by using the western blot and the immunofluorescent antibody technique (IFAT). The new parasitic microsporidium has specific polypeptide patterns comparable to the reported fish microsporidians. The main antigenic substances are concentrated on the surface of spores, and are mostly located on the anterior and posterior end of the spore bodies. Most surface components of the G. epinephelusis spores are soluble, The potential role of the surface components in initiating infection was also discussed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

To study the immunologic function of bursin, we analyzed the effects of anti-bursin monoclonal antibody (mAb) on the immunosuppression in ducks (Cherry Valley duck) by injecting various doses of the anti-bursin mAb into 13-d duck embryos. After hatch, cell-mediated immune activity and humoral responses were studied using lymphocyte proliferation test, tube agglutination test, and indirect enzyme-linked immuno-sorbent assay to detect anti-Escherichia coli antibodies and antibodies to Riemerella anatipester, respectively. Simultaneously, relative weights (BW-adjusted) of bursa of Fabricius (BF), spleen, and thymus were determined. Additionally, the morphology of BF, spleen, and thymus was examined at various ages using conventional histology. Follicle morphology of BF was analyzed by image analysis. The results indicated that anti-bursin mAb markedly decreased duck lymphocyte proliferation, the antibody-producing ability to bacteria, as well as the relative BF weight. Moreover, the anti-bursin mAb hindered the development of BF follicles.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BALB/c mice were immunized intragastrically with human sperm. Cells from the Peyer's patches and spleens of the immunized mice were for the preparation of hybridomas secreting antisperm monoclonal IgA (mcIgA). The specific ratio of IgA-secreting cells in Peyer's patches was much higher than that in spleen. The binding site on human sperm of 9 of 19 mcIgA was in the post-acrosomal region using an immunofluorescent assay. Two of eight selected mcIgA caused strong human sperm agglutination and three of them produced significant inhibition of mouse in vitro fertilization. No mcIgA tested caused obvious human sperm immobilization or inhibited mouse in vivo fertilization. In vitro assembly of selected mcIgA in ascites with mouse secretory component (SC) caused no significant changes in effects on sperm function and in vitro fertilization. By use of Western blotting, dimer or higher polymers were demonstrated in all selected mcIgAs and corresponding protein antigens in 6 of 8 selected mcIgAs. These results suggest that human sperm function may be inhibited and fertilization rate reduced by specific secretory IgA to human sperm and that secretory immunity to protein antigens of human sperm could be induced by intragastrointestinal immunization.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The kinetics of mucosal and serum antibody response is well as antibody secreting cells (ASCs) production were studied in large yellow croaker following vaccination with inactivated Vibrio harveyi by different routes: oral administration. intraperitoneal (IP) injection and immersion. Indirect ELISA was used to measure the antibody level in serum and cutaneous mucus, and ELISPOT was used to monitor the ASCs derived from gill, blood and head kidney. The data demonstrated that IP injection resulted in the highest antibody levels in the systemic circulation, whereas immersion induced significant antibody levels in mucous. As for the ASCs response, IP injection induced high numbers of ASCs in the head kidney and blood; oral intubation only induced a slight ASCs response in the head kidney: immersion induced a much stronger ASCs response in the gill. These results indicate that mucosal antibodies following immersion immunization are independent of a systemic response and more sensitive, since it could be triggered earlier than serum antibodies. The mucosal antibodies following IP injection immunization may depend oil a systemic immune response. The protective effects of the three vaccination methods were compared by challenging with live V. harveyi. Survival of the three groups of vaccinated fish varied front 40 to 60%. while 100% mortality was found in control fish. Compared with IP and oral vaccination, immersion stimulated higher specific antibody titers in the mucosal system and achieved similar protection, so it is in effective and efficient method for immunizing a large number of fish against V harveyi (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The biosensor based on surface plasmon resonance(SPR) technology is a very useful tool to study the interaction between biomolecles. The main advantages of this technique is to "visualize" macromolecular interactions directly in real time, and in a label-free mode rather than indirect methods like enzyme-linked immunosorbent assays (ELISAs). We immobilize human serum albumin (HSA) to the carboxymethyldextran-modified sensor chip surface covalently to detect the activity of anti-HSA in serum, and regenerate the surface with .1 mol/L phosphoric acid. The results show that SPR biosensor can detect the activity of anti-HSA in real-time quickly and the sensor chip can be used over 100 cycles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present paper the rarefied gas how caused by the sudden change of the wall temperature and the Rayleigh problem are simulated by the DSMC method which has been validated by experiments both in global flour field and velocity distribution function level. The comparison of the simulated results with the accurate numerical solutions of the B-G-K model equation shows that near equilibrium the BG-K equation with corrected collision frequency can give accurate result but as farther away from equilibrium the B-G-K equation is not accurate. This is for the first time that the error caused by the B-G-K model equation has been revealed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Micro-indentation test at scales on the order of sub-micron has shown that the measured hardness increases strongly with decreasing indent depth or indent size, which is frequently referred to as the size effect. Simultaneously, at micron or sub-micron scale, the material microstructure size also has an important influence on the measured hardness. This kind of effect, such as the crystal grain size effect, thin film thickness effect, etc., is called the geometrical effect by here. In the present research, in order to investigate the size effect and the geometrical effect, the micro-indentation experiments are carried out respectively for single crystal copper and aluminum, for polycrystal aluminum, as well as for a thin film/substrate system, Ti/Si3N4. The size effect and geometrical effect are displayed experimentally. Moreover, using strain gradient plasticity theory, the size effect and the geometrical effect are simulated. Through comparing experimental results with simulation results, length-scale parameter appearing in the strain gradient theory for different cases is predicted. Furthermore, the size effect and the geometrical effect are interpreted using the geometrically necessary dislocation concept and the discrete dislocation theory. Member Price: $0; Non-Member Price: $25.00

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on the theory of the pumping well test, the transient injection well test was suggested in this paper. The design method and the scope of application are discussed in detail. The mathematical models are developed for the short-time and long-time transient injection test respectively. A double logarithm type curve matching method was introduced for analyzing the field transient injection test data. A set of methods for the transient injection test design, experiment performance and data analysis were established. Some field tests were analyzed, and the results show that the test model and method are suitable for the transient injection test and can be used to deal with the real engineering problems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present research, microstructures of the surface-nanocrystalline Al alloy material are observed and measured based on the transmission electron microscopy (TEM) technique, and the corresponding mechanical behaviors are investigated experimentally and theoretically. In the experimental research, the nanoindentation test method is used, and the load and microhardness curves are measured, which strongly depend on the grain size and grain size nonuniformity. Two kinds of the nanoindentation test methods are adopted: the randomly selected loading point method and the continuous stiffness method. In the theoretical modeling, based on the microstructure characteristics of the surface-nanocrystalline Al alloy material, a dislocation pile-up model considering the grain size effect and based on the Mott theory is presented and used. The hardness-indent depth curves are predicted and modeled.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Peel test methods are assessed through being applied to a peeling analysis of the ductile film/ceramic substrate system. Through computing the fracture work of the system using the either beam bend model (BB model) or the general plane analysis model (GPA model), surprisingly, a big difference between both model results is found. Although the BB model can capture the plastic dissipation phenomenon for the ductile film case as the GPA model can, it is much sensitive to the choice of the peeling criterion parameters, and it overestimates the plastic bending effect unable to capture crack tip constraint plasticity. In view of the difficulty of measuring interfacial toughness using peel test method when film is the ductile material, a new test method, split test, is recommended and analyzed using the GPA model. The prediction is applied to a wedge-loaded experiment for Al-alloy double-cantilever beam in literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract: Avidin layer was bound on the substrate surface of Silicon wafer modified with aldehyde. The interaction between avidin and biotin was adopted for the immobilization of mouse monoclonal biotin-anti-M13 (antibody GP3)-labeled biotin. The surface was incubated in a solution containing phage M13KO7, which was trapped by the antibody GP3 with the interaction between phage M13KO7 and antibody GP3, resulting in a variation of layer thickness that was detected by imaging ellipsometry. The results showed a saturated layer of antibody GP3 with a thickness about 6.9 nm on the surface of the silicon wafer. The specific interaction between phage M13KO7 and antibody GP3 resulted in a variation of layer thickness. The layer of phage M13KO7 bound with antibody GP3 was 17.5 nm in the concentration of 1.1×1010 pfu/mL. Each variation of the layer thickness corresponded to a concentration of phage M13KO7 in the range of 0.1×1010–2.5×1010 pfu/mL, with the sensitivity of 109 pfu/mL. Compared with other methods, the optical protein-chip, requiring only short measurement time, label free, is a quantitative test, and can be visualized. This study could be significant on the interactions between the antibody and the virus, showing potential in the early diagnosis of virosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The tensile deformation and failure of polymer bonded explosives (PBXs), a particulate composite, is studied in this paper. Two HMX-based PBXs with different binder were selected for study. A diametric compression test, in which a disc-shaped specimen is loaded diametrically, was chosen to generate tensile failure in the materials. The quasi-static tensile properties and the tensile creep properties were studied by using conventional displacement transducers to measure the lateral strain along the horizontal diameter. The whole-field in-plane creep deformation was measured by using the technique of high resolution moire´ interferometry. Real time microscopic examination was conducted to monitor the process of deformation and failure of PBXs by using a scanning electron microscope equipped with a loading stage. A manifold method (MM) was used to simulate the deformation and failure of PBX samples under the diametric compression test, including the crack initiation, crack propagation and final cleavage fracture. The mechanisms of deformation and failure of PBXs under diametric compression were analyzed. The diametric compression test and the techniques developed in this research have proven to be applicable to the study of tensile properties of PBXs.