20 resultados para In-sample

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A rapid bioassay was established measuring the extracts of wildlife samples which were taken from Ya-Er Lake area, China. In extracts of these samples containing PCDD/Fs and PCBs, bioassay and chemically derived TCDD-equivalents (TEQs) were nearly identical. Our results indicate this bioassay is an excellent complement to chemical residue analysis and a useful tool in understanding the complex interactions of halogenated hydrocarbons. However, it must be mentioned that the proper prior clean-up method is very important for using the bioassay.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A rapid and sensitive method for separation and determination of Cr(VI) and Cr(III) in bottom mud of lake by flow injection on-line preconcentrtion system and GFAAS was developed. The available Cr(VI) and Cr(III) were extracted by HOAc or EDTA + NH4 NO3 and adsorbed simultaneously by an anion and a cation resin microclummn and then eluted simultaneously by 2 mol/L NH4 NO3 + 0.05 mol/L ascorbate and 2 mol/L H2SO4, respectively. The elution was performed for 50 s after adsorption for 2 min, and the efficiencies of elution were 85.4% - 94.8% and 96.7% - 106% for Cr(VI) and Cr(M) respectively. The detection limits of the method were 0.9 mu g/L and 2.7 mu g/L with relative standard deviations of 3.5% and 6.4% for the determination of Cr(VI) and Cr(III) in sample, respectively.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In this work, both,solid phase microextraction (SPME) and solid phase extraction(SPE) were used to enrich organochlorine compounds in water samples and analyzed by gas chromatography with electron capture detector. The operating conditions of SPME have been studied and different kinds of solid phase were compared. Linear alkybenzene sulfonate(LAS) was added to the samples to investigate its effect on the analysis. The results indicated that polyacrylate was better than other commercial solid phases in extraction of moderated polar organic compounds and the sensitivity of SPME was higher than SPE. LAS affect much in liquid-liquid extraction and headspace SPME; but it has little effect on SPE and direct-SPME method. The applications showed that SPME was a fast and effective method in sample preparation.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

AlGaN/GaN npn heterojunction bipolar transistor structures were grown by low-pressure MOCVD. Secondary ion mass spectroscopy (SIMS) measurements were carried out to study the Mg memory effect and redistribution in the emitter-base junction. The results indicated that there is a Mg-rich film formed in the ongrowing layer after the Cp2Mg source is switched off. The Mg-rich film can be confined in the base section by switching off the Cp2Mg source for appropriate time before the end of base growth. Low temperature growth of the undoped GaN spacer suppresses the Mg redistribution from Mg rich film. The delay rate of the Mg profile in sample C with spacer growing in low temperature is about 56 nm/decade, which becomes sharper than 80 nm/decade of the samples A and B without low temperature spacer. (C) 2005 Elsevier Ltd. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Infrared absorption spectroscopy, optical transient current spectroscopy (OTCS), and photoluminescence (PL) spectroscopy are used to investigate the annealing induced evolution of defects in low-temperature (LT)-grown GaAs-related materials. Two LT samples of bulk GaAs (sample A) and GaAs/AlxGa1-xAs multiple-quantum-well. (MQW) structure (sample B) were grown at 220 and 320 degreesC on (001) GaAs substrates, respectively. A strong defect-related absorption band has been observed in both as-grown samples A and B. It becomes weaker in samples annealed at temperatures above 600 degreesC. In sample A, annealed in the range of 600-800 degreesC, a large negative decay signal of the optical transient current (OTC) is observed in a certain range of temperature, which distorts deep-level spectra measured by OTCS, making it difficult to identify any deep levels. At annealing temperatures of 600 and 700 degreesC, both As-Ga antisite and small As cluster-related deep levels are identified in sample B. It is found that compared to the As cluster, the As-Ga antisite has a larger activation energy and carrier capture rate. At an annealing temperature of 800 degreesC, the large negative decay signal of the OTC is also observed in sample B. It is argued that this negative decay signal of the OTC is related to large arsenic clusters. For sample B, transient PL spectra have also been measured to study the influence of the, defect evolution on optical properties of LT GaAs/AlxGa1-xAs MQW structures. Our results clearly identify a defect evolution from AS(Ga) antisites to arsenic clusters after annealing.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Undoped high resistivity (HR) GaN epilayers were grown on (0001) sapphire substrate by metalorganic chemical vapor deposition (MOCVD). Thermally stimulated current (TSC) and resistivity measurements have been carried out to investigate deep level traps. Deep levels with activation energies of 1.06eV and 0.85eV were measured in sample 1. Gaussian fitting of TSC spectra showed five deep levels in different samples. (c) 2006 WILEY VCH Vertag GmbH & Co. KGaA, Weinheim

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This work evaluates the effect of wavelength positioning errors in spectral scans on analytical results when the Kalman filtering technique is used for the correction of line interferences in inductively coupled plasma atomic emission spectrometry (ICP-AES). The results show that a positioning accuracy of 0.1 pm is required in order to obtain accurate and precise estimates for analyte concentrations. The positioning error in sample scans is more crucial than that in model scans. The relative bias in measured analyte concentration originating from a positioning error in a sample scan increases linearly with an increase in the magnitude of the error and the peak distance of the overlapping lines, but is inversely proportional to the signal-to-background ratio. By the use of an optimization procedure for the positions of scans with the innovations number as the criterion, the wavelength positioning error can be reduced and, correspondingly, the accuracy and precision of analytical results improved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The corrosion behaviour of titanium substance and the XPS characterization of Ti surface in the H2C2O4 solution have been first studied by X-ray photoelectron spectroscopy, The experimental results show that there am mile Ti-2 and Ti2+ on sample surface in 10% H2C2O4 solution for two boars corrosion at 80 degrees C, but if corrosion is extended to 4 hones, the surface composition is mainly TiO2 with a small amount of Ti2+. This result corresponds to the structure of TiH1.642 composion in sample surface found by XRD analysis. Since bath TiO2 and the surface coating RuO2 are of Gald-Redstone structure, therefore electrode materials of Ti-Ru are stable in chemical industry.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A suitable method for the pretreutment of dissolved nitrate samples in seawaters for nitrogen isotopic analysis was established. First, the seawater samples were processed by removing nitrite and amonium. Then Devard's alloy was added in sample for conversion of dissolved nitrate to ammonium. The sample was distilled, and then the ammonium condensate was collected with zeolite. after distillation, the collected condensate was filtered and prepared for determining nitropic values. Some tests of the method were conducted. The distillation condition, the influence of salinity on nitrogen isotopic analysis, absorption of ammonium onto zeolite and an improved method on a large volume of seawater were discussed in this study. The results showed that the distillation step had an average recovery of (104.9 +/- 4.2) % (n = 6) when distillating every 300 mL aliquot of the sample under a strong alkaline condition with 0.5 g devard's alloy and a distillation time of 30 min. The nitrogen isotopic fractionation decreased markedly when salinity was increased from 0% to 0.5%; further increase(1% - 3.5%) showed little effect. The adsorption rate of ammonium onto zeolite had a high yield of (95.96 +/- 1.08) % (n = 6) in average. An improved collection method was used to process a large volume of seawater with several distillations, and had good effect on analysis. The method had been applied to analyze water samples collected from Changjiang estuary. The analytical results indicate that the method is suitable for delta N-15 analysis of dissolved nitrate in seawaters. The present method could provide valuable information about the source and cycle mechanism of dissolved nitrogen in estuary waters.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Emodin, a natural anthraquinone compound isolated from the rhizome of rhubarb, is reported to suppress the growth of tumor in many clinical situations. In this study, we focused on the effect of emodin in human breast cancer BCap-37 cells and further understand the underlying molecular mechanism in treating breast cancer. Using MTT assay and flow cytometry, we demonstrated the critical role of emodin in the suppression of the proliferation of BCap-37 cells based on a concentration- and time-dependent manner. The increase of apoptotic rate was also observed after incubation of BCap-37 cells on emodin at 20 mu M and 50 mu M for 48 h. The cells exhibited typical apoptotic features including cellular morphological change, chromatin condensation and membrane blebbing. The results of the study further showed that Bcl-2 level decreased, while Bax and cytosolic cytochrome c levels in sample cells increased after the emodin treatment by using Western blot. The decline in the Bcl-2/Bax ratio and the increase of cytosolic cytochrome c concentration were consistent with the increase of the apoptotic ratio. The results strongly suggest that the disruption of the mitochondrial signaling pathway was involved in emodin-induced apoptosis in BCap-37 cells.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A sensitive homogenous time-resolved fluoroimmunoassay (TR-FIA) method for bensulfuron-methyl (BSM) based on fluorescence resonance energy transfer (FRET) from a Tb3+ fluorescent chelate with N,N,N',N'-[2,6-bis(3'-aminomethyl-1'-pyrazoly)-4-phenylpyridine] tetrakis(acetic acid) (BPTA-Tb3+) to organic dye, Cy3 or Cy3.5 has been developed. New method combined the use of BPTA-Tb3+ labeled streptavidin, Cy3 or Cy3.5 labeled anti-BSM monoclonal antibody and biotinylated BSM-BSA conjugate (BSA is bovine serum albumin) for competitive-type immunoassay. After BPTA-Tb3+ labeled streptavidin was reacted with a competitive immune reaction solution containing biotinylated BSM-BSA, BSM sample and Cy3 or Cy3.5 labeled anti-BSM monoclonal antibody, the sensitized and long-lived emission of Cy3 or Cy3.5 derived from FRET was measured, and thus the concentration of BSM in sample was calculated. The present method has the advantages of rapidity, simplicity and high sensitivity since the B/F (bound reagent/free reagent) separation steps and the solid-phase carrier are not necessary. The method gives the detection limit of 2.10 ng ml(-1). The coefficient variations of the method are less than 1.5% and the recoveries are in the range of 95-105% for BSM water sample measurement. (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The concept ''sample-specific'' is suggested to describe the behavior of disordered media close to macroscopic failure. it is pointed out that the transition from universal scaling to sample-specific behavior may be a common phenomenon in failure models of disordered media. The dynamical evolution plays an important role in the transition.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A new method of frequency-shifting for a diode laser is realized. Using a sample-and-hold circuit, the error signal can be held by the circuit during frequency shifting. It can avoid the restraint of locking or even lock-losing caused by the servo circuit when we input a step-up voltage into piezoelectric transition (PZT) to achieve laser frequency-shifting.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Rationale: Discriminating right from left is an everyday cognitive ability. Repeated exposure to certain drugs, such as heroin, can produce poor performance on many cognitive tasks. However, it is yet unclear whether drug abuse impairs the ability of right-left discrimination. Objectives: The aim of the present study is to examine whether the spatial ability measured by the right-left discrimination task can be affected by heroin abuse and whether such drug effect, if it exists, is gender related. Methods: A paper-and-pen test was used. The test consists of line drawings of a person with no arm, one arm, or both arms crossing the vertical body axis of the figure. The line drawings are viewed from the back, from the front, or randomly alternating between the back and front drawings. The subjects task is to mark which is the right or left hand in the figure as fast as possible. Results: A main finding in this study was that the ability to discriminate between left and right in visual space was impaired in heroin-dependent patients. Especially, heroin-dependent females performed poorer than control females in all conditions but heroin-dependent males only performed poorly in part of conditions. Conclusions: Recent heroin abuse impairs the ability of right-left discrimination and such impairment is gender related: heroin-dependent females demonstrated greater performance deficits than males.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The attentional blink reveals the limits of the brain's ability in information processing. It has been extensively studied in people with neurological and psychiatric disturbances to explore the temporal characteristics of information processing and exami