7 resultados para Implantable cardioverter defibrillator

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Silicon-based microelectrodes have been confirmed to be helpful in neural prostheses. The fabricated 7-channel silicon-based microelectrode was feasible to be implanted into the brain cortex. The manufacturing process by microelectromechanical system (MEMS) technology was detailed with four photolithographic masks. The microscopic photographs and SEM images indicated that the probe shank was 3mm long, 100 mu m wide and 20 mu m thick with the recording sites spaced 120 mu m apart for good signal isolation. To facilitate the insertion and minimize the trauma, the microelectrode is narrowed down gradually near the tip with the tip taper angle of 6 degrees. Curve of the single recording site impedance versus frequency was shown by test in vitro and the impedance declined from 150.5 k Omega to 6.0 k Omega with frequency changing from 10 k to 10MHz.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A subretinal implant device, Micro Photo Diode Array, which can partly imitate the function of photoreceptor cells, was presented. Process to fabricate the MPDA and characteristics of the MPDA in vivo were described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A prototype microsystem is presented for wireless neural recording application. An inductive link was built for transcutaneous wireless power transfer and data transmission. Total 16.5 mW power and 50 bps - 2.5 Kbps command data can be received over 1 - 5 MHz with a distance of 0-10 mm. The integrated amplifiers were designed with a limited bandwidth for neural signals acquisition. The gain of 60 dB was obtained by preamplifier at 7 Hz - 3 KHz. An integrated FM transmitter was used to transmit the extracted neural signals to external equipments with 0.374 - 2 mW power comsumption and a maximum data rate of 500 Kbps at 100 MHz. All the integrated circuits modules except the power recovery circuit were tested or stimulated under a 3.3 V power supply, and fabricated in standard CMOS processing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study reports a subretinal implant device which can imitate the function of photoreceptor cells. Photodiode (PD) arrays on the chip translate the incident light into current according to the intensity of light. With an electrode at the end of every photodiode, the PDs transfer the current to the remnant healthy visual cells such as bipolar cells and horizontal cells and then activate these cells. Biocompatible character of the materials and artificial photoreceptor itself were tested and the photoelectric characteristics of the chips in simulative condition were described and discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The development of an implantable five channel microelectrode array is presented for neural signal recordings. The detailed fabrication process is outlined with four masked used. The SEM images show that the probe shank is 1.2mm long, 100 mu m wide and 30 mu m thick with the recording sites spaced 200 mu m apart for good signal isolation. The plot of the single recording site impedance versus frequency is shown by test in vitro and the ompedence declines with the increasing frequency. Experiment in vivo using this probe is under way.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The prototype wafer of a low power integrated CMOS Transmitter for short-range biotelemetry application has been designed and fabricated, which is prospective to be implanted in the human brain to transfer the extracted neural information to the external computer. The transmitter consists of five parts, a bandgap current regulator, a ring oscillator, a buffer, a modulator and a power transistor. High integration and low power are the most distinct criteria for such an implantable integrated circuit. The post-simulation results show that under a 3.3 V power supply the transmitter provides 100.1 MHz half-wave sinusoid current signal to drive the off-chip antenna, the output peak current range is -0.155 mA similar to 1.250 mA, and on-chip static power dissipation is low to 0.374 mW. All the performances of the transmitter satisfy the demands of wireless real-time BCI system for neural signals recording and processing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of the present study was to develop implantable BCNU-toaded poly(ethylene glycol)poly(L-lactic acid) (PEG-PLLA) diblock copolymer fibers for the controlled release of 1,3-bis(2-chloroethyl)-1-nitrosourea (BCNU). BCNU was well incorporated and dispersed uniformly in biodegradable PEG-PLLA fibers by using electrospinning method. Environmental Scanning Electron Microscope (ESEM) images indicated that the BCNU-loaded PEG-PLLA fibers looked uniform and their surfaces were reasonably smooth. Their average diameters were below 1500 nm. The release rate of BCNU from the fiber mats increased with the increase of BCNU loading amount. In vitro cytotoxicity assay showed that the PEG-PLLA fibers themselves did not affect the growth of rat Glioma C6 cells. Antitumor activity of the BCNU-loaded fibers against the cells was kept over the whole experiment process, while that of pristine BCNU disappeared within 48 h. These results strongly suggest that the BCNU/PEG-PLLA fibers have an effect of controlled release of BCNU and are suitable for postoperative chemotherapy of cancers.