Implantable Microsystem for Wireless Neural Recording Applications


Autoria(s): Zhang X (Zhang Xu); Pei WH (Pei Weihua); Huang BJ (Huang Beiju); Chen J (Chen Jin); Guan N (Guan Ning); Chen HD (Chen Hongda)
Data(s)

2009

Resumo

A prototype microsystem is presented for wireless neural recording application. An inductive link was built for transcutaneous wireless power transfer and data transmission. Total 16.5 mW power and 50 bps - 2.5 Kbps command data can be received over 1 - 5 MHz with a distance of 0-10 mm. The integrated amplifiers were designed with a limited bandwidth for neural signals acquisition. The gain of 60 dB was obtained by preamplifier at 7 Hz - 3 KHz. An integrated FM transmitter was used to transmit the extracted neural signals to external equipments with 0.374 - 2 mW power comsumption and a maximum data rate of 500 Kbps at 100 MHz. All the integrated circuits modules except the power recovery circuit were tested or stimulated under a 3.3 V power supply, and fabricated in standard CMOS processing.

A prototype microsystem is presented for wireless neural recording application. An inductive link was built for transcutaneous wireless power transfer and data transmission. Total 16.5 mW power and 50 bps - 2.5 Kbps command data can be received over 1 - 5 MHz with a distance of 0-10 mm. The integrated amplifiers were designed with a limited bandwidth for neural signals acquisition. The gain of 60 dB was obtained by preamplifier at 7 Hz - 3 KHz. An integrated FM transmitter was used to transmit the extracted neural signals to external equipments with 0.374 - 2 mW power comsumption and a maximum data rate of 500 Kbps at 100 MHz. All the integrated circuits modules except the power recovery circuit were tested or stimulated under a 3.3 V power supply, and fabricated in standard CMOS processing.

zhangdi于2010-03-09批量导入

zhangdi于2010-03-09批量导入

ICME.

[Zhang, Xu; Pei, Weihua; Huang, Beiju; Chen, Jin; Guan, Ning; Chen, Hongda] Chinese Acad Sci, Inst Semicond, State Key Lab Integrated Optoelect, Beijing 100083, Peoples R China

ICME.

Identificador

http://ir.semi.ac.cn/handle/172111/8366

http://www.irgrid.ac.cn/handle/1471x/65882

Idioma(s)

英语

Publicador

IEEE

345 E 47TH ST, NEW YORK, NY 10017 USA

Fonte

Zhang, X (Zhang, Xu); Pei, WH (Pei, Weihua); Huang, BJ (Huang, Beiju); Chen, J (Chen, Jin); Guan, N (Guan, Ning); Chen, HD (Chen, Hongda) .Implantable Microsystem for Wireless Neural Recording Applications .见:IEEE .2009 ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING,345 E 47TH ST, NEW YORK, NY 10017 USA ,2009,234-237

Palavras-Chave #光电子学 #SYSTEM
Tipo

会议论文