11 resultados para Chlorpromazine
em Chinese Academy of Sciences Institutional Repositories Grid Portal
Resumo:
Phenothiazine drugs, chlorpromazine hydrochloride (CPZ) and promethazine hydrochloride (PMZ), were determined with Ru(bpy)(3)(2+) electrochemiluminescene by the capillary electrophoresis (CE-ECL). It was found that both CPZ and PMZ could produce an intermediate that acted as coreactants to react with Ru(bpy)(3)(2+) to produce excited states which were capable of emitting light. This CE-ECL detection method had high sensitivity, good selectivity and reproducibility for CPZ and PMZ determination.
Resumo:
The spectroscopic and transmission electron microscopy (TEM) studies of interaction between chlorpromazine (CPZ) and dimyristoyl phosphatidylglycerol (DMPG) bilayer by using gold nanoparticles (AuN-Ps) as probes are reported. The DMPG bilayer-protected AuNPs were prepared by a simple one-step method. The DMPG bilayer tethered on the AuNPs was considered as a biomembrane model. The addition of CPZ affected the surface plasmon resonance (SPR) and morphology of the prepared AuNPs, and this effect was monitored by UV-vis spectroscopy and TEM.
Resumo:
The interaction of chlorpromazine (CPZ) with supported bilaver lipid (dipalmitoyphosphatidylcholine) membrane (s-BLM) on the glassy carbon electrode (GCE) was investigated using cyclic voltammetry and ac impedance spectroscopy. The experimental data, based on the voltammetric response of Ru(NH3)(6)(3+) associated with the oxidation of CPZ on the electrode, indicated that the interaction of CPZ with s-BLM was concentration and time dependant. The interaction between them could be divided into three stages by the concentration of CPZ: low, middle and high concentration. At the first stage, s-BLM was not affected by CPZ and the interaction was only a penetration of a small quantity of CPZ molecule into s-BLM. At the second stage, the defects formed in s-BLM due to the penetration of more CPZ molecule into s-BLM. At the last stage, a high CPZ:lipid ratio reached in s-BLM, resulting in the solubilization of s-BLM. The interaction time had different effect at three stages.
Resumo:
A new detection scheme for the determination of adsorbable coreactants of Ru(bpy)(3)(2+) electrochemiluminescent reaction is presented. It is based on selective preconcentration of coreactant onto an electrode, followed by Ru(bpy)(3)(2+) electrochemiluminescent detection. The coreactant employed is chlorpromazine. It was sensitively detected after 5-min preconcentration onto a lauric acid-modified carbon paste electrode. The linear concentration range was found to occur from 1 x 10(-8) to 3 x 10(-6) mol L-1 with a detection limit of 3.1 x 10(-9) mol L-1. The total analysis time is less than 10 min. As a result of selective preconcentration and medium exchange, such remarkable selectivity is achieved that reproducible quantitation of chlorpromazine in urine is possible.
Resumo:
A simultaneous electrochemiluminescence (ECL) and electrochemical (EC) detection scheme for NACE was presented for fast analysis of tertiary amines. Both ECL and EC signals were generated at the same Pt electrode. Triethylamine (TEA), tripropylamine (TPrA), chlorpromazine, promethazine, and dioxopromethazine (DPZ) were selected to validate NACE-ECL/EC dual detection strategy. The linear ranges for TEA and TPrA were 0.01-500 and 0.01-10 mu M with the detection limits of 8.0 and 5.0 nM (S/N=3), respectively. The RSDs (n = 6) of the migration time and the ECL intensity for 1 mu M TEA and 0.5 mu M TPrA were 0.1 and 2.8%, and 0.2 and 1.8% with theoretical plate numbers of 180 000 and 700 000 per meter, respectively. These two analytes could be separated within 92 s and the Pt electrode did not need reactivation during the experiments.
Resumo:
Ceramic carbon materials were developed as new sorbents for solid-phase extraction of organic compounds using chlorpromazine as a representative. The macroporosity and heterogeneity of ceramic carbon materials allow extracting a large amount of chlorpromazine over a short time. Thus, the highly sensitive and selective determination of chlorpromazine in urine sample was achieved by differential pulse voltammograms after only 1-min extraction. The total analysis time was less than 3 min. In comparison with other electrochemical and electrochemi-luminescent methods following 1-min extraction, the proposed method improved sensitivity by about 2 and 1 order of magnitude, respectively. The fast extraction, diversity, and conductivity of ceramic carbon materials make them promising sorbents for various solid-phase extractions, such as solid-phase microextraction, thin-film microextraction, and electrochemically controlled solidphase extraction. The preliminary applications of ceramic carbon materials in chromatography were also studied.
Resumo:
An electrochemiluminescence (ECL) sensor with good long-term stability and fast response time has been developed. The sensor was based on the immobilization of tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)(3)(2+)) into the Eastman-AQ55D-silica composite thin films on a glassy carbon electrode. The ECL and electrochemistry of Ru(bpy)(3)(2+) immobilized in the composite thin films have been investigated, and the modified electrode was used for the ECL detection of oxalate, tripropylamine (TPA) and chlorpromazine (CPZ) in a flow injection analysis system and showed high sensitivity. Because of the strong electrostatic interaction and low hydrophobicity of Eastman-AQ55D, the sensor showed no loss of response over 2 months of dry storage. In use, the electrode showed only a 5% decrease in response over 100 potential cycles. The detection limit was 1 mumol l(-1) for oxalate and 0.1 mumol l(-1) for both TPA and CPZ (S/N = 3), respectively. The linear range extended from 50 mumol l(-1) to 5 mmol l(-1) for oxalate, from 20 mumol l(-1) to 1 mmol l(-1) for TPA, and from 1 mumol l(-1) to 200 mumol l(-1) for CPZ.
Resumo:
A new electrochemiluminescence (ECL) microoptoprobe with simple structure. small sampling volume and high efficiency was developed. It was constructed by fixing the transparent gold mini-grid on the end surface of the optical fiber, and by surrounding the fiber with the counter- and reference electrodes to form a self-contained three-electrode system. The use of mini-grid electrode increased the surface area and collection efficiency. which resulted in higher ECL signal and better sensitivity. The counter electrode together with one end of the fiber formed a mini-vessel, which eliminated the need of additional container and allowed to perform ECL detection in a very small volume (about 10 mul). The microoptoprobe obtained was characterized with the Ru(bpy)(3)(2-)-tripropylamine system and was applied for the determination of oxalate and chlorpromazine (CPZ). Detection limits (S/N = 3) were 5 x 10(-7) and 1 x 10(-6) mol l(-1) for oxalate and CPZ. respectively. The linear range for oxalate and CPZ extended from 1 x 10(-6) to 1 x 10(-3) mol l(-1), and from 5 x 10(-6) to 5 x 10(-4) mol l(-1). respectively.
Resumo:
Four phenothiazines, promethazine, dioxypromethazine, chlorpromazine, and trifluoperazine have been separated by capillary electrophoresis using N, N, -dimethylformamide (DMF) as separation medium with UV absorbance detection. High voltage and concentrated buffer were used with small current and low electroosmosis. Good resolution and high column efficiency were obtained. Separation selectivity in DMI; was different from that in water because of the different solvation interactions. The influence of buffer composition on separation selectivities and electroosmosis were also studied.
Resumo:
Separations of phenothiazines, promethazine(PZ), dioxypromethazine (OZ), chlorpromazine(CZ), trifluoperazine(TfZ) and thioridazine(TZ) by capillary electrophoresis in water and FA media were carried out and compared. Thus different selectivity and resolution were observed as media varying from water to FA. Migration order was PZ, OZ, CZ and TZ in water but (TZ+PZ), CZ and OZ in FA, when the same buffer, 25 mmol/L Tris and 25 mmol/L citric acid, was used. It also has been observed that pH has great effect on selectivity both in water and FA and a possible explanation was given. Separation efficiency was higher in FA media than in water because of the permission of high voltage applied. For all separations in FA 30 kV was applied, and when 25 mmol/L Tris was used as buffer, current was only 20 mu A and complete separation of TZ, CZ, PZ and OZ was achieved with effencicy higher than 3.5 x 10(5) theoretical plates for all analytes. The high performance of capillary electrophoresis in FA suggests that FA is an excellent media separation.