11 resultados para , Design Experiment
em Chinese Academy of Sciences Institutional Repositories Grid Portal
Resumo:
Based on the theory of the pumping well test, the transient injection well test was suggested in this paper. The design method and the scope of application are discussed in detail. The mathematical models are developed for the short-time and long-time transient injection test respectively. A double logarithm type curve matching method was introduced for analyzing the field transient injection test data. A set of methods for the transient injection test design, experiment performance and data analysis were established. Some field tests were analyzed, and the results show that the test model and method are suitable for the transient injection test and can be used to deal with the real engineering problems.
Resumo:
In the history of psychology research, more attention had been focused on the relation between local processing and global processing. For the global information and the local information, which is processed earlier? And which is processed faster? Precedence of the global over the local level in visual perception has been well established by Navon with compound stimuli, and Navon’s original study gave rise to many publications, including replications, generalization to other kinds of stimuli (nonverbal material, digits), populations (infants, children, brain-damaged subjects), and tasks (lateral visual hemifield presentation, copy drawing, memory recognition, and recall), and triggered some debate about the conditions in which global precedence is and is not observed (number, size, sparsity, and goodness of the stimuli, exposure duration, etc.). However, whether there is a global advantage or precedence in other cognitive processes was less tested. Most researches had suggested that there was a functional equivalency between visual perception and visual image processing. However, it’s still unknown whether there will be a global advantage on mental rotation. In the present study, we combined the mental rotation task with the compound stimuli to explore whether the global or local advantage also existed at the mental imagery transformation stages. In two pilot studies, the perceptual global precedence was found to be present in a normal/mirror-image judgment task when the stimuli exposure time was short; while the stimuli exposure time was prolonged (stimuli kept available till subjects’ response) the perceptual global precedence was showed to be eliminated. In all of the subsequent experiments, stimili would be presented till subjects’ response. Then mental rotation was added in normal/mirror-image judgment (some of the stimuli were rotated to certain angles from upright) in normal experiments, experiment 1 and 2 observed a global advantage on mental rotation both with a focused-attention design (Experiment 1) and divided-attention design (Experiment 2). Subjects’ reaction times were increased with rotation angles, and the accuracy was decreased with rotation angles, suggesting that subject need a mental rotation to make a normal/mirror judgment. The most important results were that subjects’ response to global rotation was faster than that to local rotation. The analysis of slope of rotation further indicated that, to some extend, the speed of global rotation was faster than that of local rotation. These results suggest a global advantage on mental rotation. Experiment 3 took advantage of the high temporal resolution of event-related potentials to explore the temporal pattern of global advantage on mental rotation. Event-related potential results indicated the parietal P300 amplitude was inversely related to the character orientation, and the local rotation task delayed the onset of the mental-rotation-related negativity at parietal electrodes. None clear effect was found for occipital N150. All these results suggested that the global rotation was not only processed faster than local rotation, but also occurred earlier than local rotation. Experiments 4 and 5 took the effect size of global advantage as the main dependent variable, and visual angle and exposure duration of the stimuli as independent variables, to examine the relationship between perceptual global precedence and global advantage on mental rotation. Results indicated that visual angle and exposure duration did not influence the effect size of global advantage on mental rotation. The global advantage on mental rotation and the perceptual global advantage seemed to be independent but their effects could be accumulated at some condition. These findings not only contribute to revealing a new processing property of mental rotation, but also deepen our understanding of the problem of global/local processing and shed light on the debate on locus of global precedence.
Resumo:
Mechanical principles of fibre-optic disc accelerometers (FODA) different from those assumed in previous calculation methods are presented. An FODA with a high sensitivity of 82 rad/ g and a resonance frequency of 360 Hz is designed and tested. In this system, the minimum measurable demodulation phase of the phase-generated carrier (PGC) is 10(-5) rad, and the minimum acceleration reaches 120 ng theoretically. This kind of FODA, with its high responsivity, all-optic-fibre configuration, small size, light weight and stiff shell housing, ensures effective performance in practice.
Resumo:
A high detection efficiency calorimeter which is used to detect gamma-rays with energies from 1 MeV up to 10 MeV as well as light charged particles has been proposed. Design of the geometry, results of the crystal tests and Monte Carlo simulations are presented in this paper. The simulation results confirm that the calorimeter can obtain high detection efficiency and good energy resolution with the current designed geometry. And the calorimeter is competent for the future External Target Facility (ETIF) experiments.
Resumo:
Aperture patterns play a vital role in coded aperture imaging ( CAI) applications. In recent years, many approaches were presented to design optimum or near-optimum aperture patterns. Uniformly redundant arrays (URAs) are, undoubtedly, the most successful for constant sidelobe of their periodic autocorrelation function. Unfortunately, the existing methods can only be used to design URAs with a limited number of array sizes and fixed autocorrelation sidelobe-to-peak ratios. In this paper, we present a novel method to design more flexible URAs. Our approach is based on a searching program driven by DIRECT, a global optimization algorithm. We transform the design question to a mathematical model, based on the DIRECT algorithm, which is advantageous for computer implementation. By changing determinative conditions, we obtain two kinds of types of URAs, including the filled URAs which can be constructed by existing methods and the sparse URAs which have never been mentioned by other authors as far as we know. Finally, we carry out an experiment to demonstrate the imaging performance of the sparse URAs.
Resumo:
In petawatt laser system, the gratings used to compose pulse compressor are very large in size which can be only acquired currently by arraying small aperture gratings to form a large one instead, an approach referred to as grating tiling. Theory and experiments have demonstrated that the coherent addition of multiple small gratings to form a larger grating is viable, the key technology of which is to control the relative position and orientation of each grating with high precision. According to the main factors that affect the performance of the grating tiling, a 5-DOF ultraprecision stage is developed for the grating tiling experiment. The mechanism is formed by serial structures. The motion of the mechanism is guided by flexure hinges and driven by piezoelectric actuators and the movement resolution of which can achieve nanometer level. To keep the stability of the mechanism, capacitive position sensors with nanometer accuracy are fixed on it to provide feedback signals with which to realize closed-loop control, thus the positioning precision of the mechanism is within several nanometers range through voltage control and digital PID algorithm. Results of experiments indicate that the performance of the mechanism can meet the requirement of precision for grating tiling.}
Resumo:
The objective of this study is to improve the stability of pumping source of optical parametric amplifier. Analysis by simulation leads to the conclusion that the stability of the second harmonic can be improved by using properly the intensity of fundamental light and corresponding length of the crystal. By the method of the noncollinear two-pass second harmonic or the tandem second harmonic, the efficient crystal length is extended to a proper value, and the stability of the second harmonic output has been improved two times more than that for the fundamental light, and the conversion-efficiency is about 70% in experiment. When the variation of the fundamental light is about 10%, the variation of the second harmonic intensity has been controlled within 5%. (c) 2006 Elsevier Ltd. All rights reserved.
Resumo:
Aeromonas hydrophila and Vibrio fluvialis are the causative agents of a serious haemorrhagic septicaemia that affects a wide range of freshwater fish in China. In order to develop a bivalent anti-A. hydrophila and anti-V. fluvialis formalin-killed vaccine to prevent this disease, an orthogonal array design (OAD) method was used to optimize the production conditions, using three factors, each having three levels. The effects of these factors and levels on the relative per cent survival for crucian carp were quantitatively evaluated by analysis of variance. The final optimized formulation was established. The data showed that inactivation temperature had a significant effect on the potency of vaccine, but formalin concentration did not. The bivalent vaccine could elicit a strong humoral response in crucian carp (Carassius auratus L.) against both A. hydrophila and V. fluvialis simultaneously, which peaked at 3 or 5 weeks respectively. Antibody titres remained high until week 12, the end of the experiment, after a single intraperitoneal injection. The verification experiment confirmed that an optimized preparation could provide protection for fish at least against A. hydrophila infection, and did perform better than the non-optimized vaccine judged by the antibody levels and protection rate, suggesting that OAD is of value in the development of improved vaccine formulations.
Resumo:
High performance InGaAsP/InGaAsP strained compensated multiple-quantum-well (MQW) electroabsorption modulators (EAM) monolithically integrated with a DFB laser diode have been designed and realized by ultra low metal-organic vapor phase epitaxy (MOVPE) based on a novel butt joint scheme. The optimization thickness of upper SCH layer for DFB and EAM was obtained of the proposed MQW structure of the EAM through numerical simulation and experiment. The device containing 250(mu m) DFB and 170(mu m) EAM shows good material quality and exhibits a threshold current of 17mA, an extinction ratio of higher than 30 dB and a very high modulation efficiency (12dB/V) from 0V to 1V. By adopting a high-mesa ridge waveguide and buried polyimide, the capacitance of the modulator is reduced to about 0.30 pF corresponding to a 3dB bandwidth more than 20GHz.
Resumo:
An index-coupled distributed feedback laser with the sampled grating has been designed and fabricated. The +1(st) order reflection of the sampled grating is utilized for laser single mode operation, which is 1.5329 mu m in the experiment. The sampled grating is formed by a conventional holographic exposure combined with the usual photolithography. The typical threshold current of DFB laser with the sampled grating is 25mA, and the optical output is about 10mW at the injected current of 100mA.
Resumo:
Abstract A state-of-the-art high energy heavy ion microbeam irradiation system is constructed at the Institute of Modern Physics of the Chinese Academy of Sciences. This microbeam system operates in both full current intensity mode and single ion mode. It delivers a predefined number of ions to preselected targets for research in biology and material science. The characteristic of this microbeam system is high energy and vertical irradiation. A quadrupole focusing system, in combination with a series of slits, has been designed to optimize the spatial resolution. A symmetrically achromatic system leads the beam downwards and serves simultaneously as an energy analyzer. A high gradient quadrupole triplet finally focuses a C6+ ion beam to 1 µm in the vacuum chamber within the energy range from 10 MeV/u to 100 MeV/u. In this paper, the IMP microbeam system is described in detail. A systematic investigation of the ion beam optics of this microbeam system is presented together with the associated aberrations. Comparison is made between the IMP microbeam system and the other existing systems to further discuss the performance of this microbeam. Then the optimized initial beam parameters are given for high resolution and high hitting efficiency. At last, the experiment platform is briefly introduced.