310 resultados para amperometric biosensor


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A kind of solid substrate, glassy carbon (GC) electrode. was selected to support self-assembled lipid layer membranes. On the surface of GC electrode. we made layers of dimyristoylphosphatidylcholine (DMPG, a kind of lipid). From electrochemical impedance experiments. we demonstrated that the lipid layers on the GC electrode were bilayer lipid membranes. We immobilized horseradish peroxidase (HRP) into the supported bilayer lipid membranes (s-BLM) to develop a kind of mediator-free biosensor for H2O2. The biosensor exhibited fine electrochemical response, stability and reproducibility due to the presence of the s-BLM. As a model of biological membrane, s-BLM could supply a biological environment for enzyme and maintain its activity. So s-BLM is an ideal choice to immobilize enzyme for constructing the mediator-free biosensor based on GC electrode. (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have made a cheap microsystem of capillary electrophoresis with a new method, integrating the electrodes, injection channel, separation channel, buffer reservoirs and detection cell on a polymethylmethacrylate (PMMA) chip. Using an integrated micro carbon fiber disk electrode as the working electrode in three electrodes system, 1 x 10(-4) mol/L dopamine(DA) could be detected with end-column amperometric detection. The reproducibility was good. Peak current was 6.73 nA,theoretical plate number was 71300/m and height equivalent of one theoretical plate height was 14.0 mum for 1 x 10(-4) mol/L DA. The limit of detection was 3.6 x 10(-8) mol/L and the linear range was extended from 5 x 10(-7) mol/L to 1 x 10(-4) mol/L for DA. 1 x 10(-4) mol/L catechol (CA) and 5 x 10(-5) mol/L DA were also separated completely with R-s = 10.1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Graphite powder-supported nickel(II) hexacyanoferrate (NiHCF) was prepared by the in situ chemical deposition method and then dispersed into methyltrimethoxysilane-derived gels to form a conductive composite. The composite was used as electrode material to construct a surface-renewable three-dimensional NiHCF-modified carbon ceramic electrode. Electrochemical behavior of the chemically modified electrode was well characterized using cyclic and square-wave voltammetry. The electrode presented a good electrocatalytic activity toward the oxidization of thiosulfate and thus was used as an amperometric sensor for thiosulfate in the photographic waste effluent. In addition, the electrode exhibited a distinct advantage of surface-renewal by simple mechanical polishing, as well as simple preparation, good chemical and mechanical stability. (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Determination of aesculin (AL) and aesculetin (AT) by capillary electrophoresis with end-column amperometric detection using a 33 mu m microdisk carbon fiber electrode is described. The HDVs, the effect of pH, buffer concentration, injection voltage, injection time and separation voltage on the peak current response (i(p)) of the analytes and the number of theoretical plates (N) were studied. The method has high sensitivity and good reproducibility. Under the optimum condition - 10 mM, pH 9.00 phosphate buffer, 4 s at 9 kV injection, separation at 15 kV and +1.0 V as the detection potential - low detection limits (S/N = 3) of 0.06 and 0.3 mu M were obtained for AL and AT, respectively. The calibration curve was linear over three orders of magnitude. The relative standard deviations (n = 15) of peak current and migration time were 3.9% and 4.6%, and 0.96% and 0.75% for 15 consecutive injections of 5 mu M AL and AT, respectively. The use of this method for the separation and detection of the two compounds present in the traditional Chinese medicine and human urine samples is also reported. (C) 1999 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

End-column amperometric detection of 6-mercaptopurine by capillary zone electrophoresis was described with high resolution and speed. The detection conditions were optimized and the electrochemical behavior was observed. Under the optimal conditions: detection potential of 1.2 V ( vs. Ag/AgCl), operating voltage of 15 kV, sample injection of 3 s at 15 kV and 10 mmol/l Na2HPO4 buffer, the detection limit for 6-MP was as low as 1 x 10(-7) mol/L and the linear range was from 5 x 10(-4) to 5 x 10(-6) mol/L with the relative coefficient of 0.995. The RSD of reproducibility for peak current and migration time was 2.5% and 1.2%, respectively. This method was utilized in assay real sample of human mine and bovine serum albumin containing 6-mercaptopurine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new electrochemical cell assembly with the combination of UV and amperometric detector (AD) based on their complementarity was described. A Nafion tubing junction was used to decouple the high voltage from the separation capillary in the rear of on-column UV detector. In this mode, the electroactive and inert compounds could be detected by UV and AD at the same time. Aromatic amines were determined with the UV and the end-column AD detection to evaluate the performances of the cell assembly. Such an improved electrochemical detector could match the capillary with different diameters. By simple adjustment of the screws, the positioning of the working electrode and the detection capillary was easily gained without microscope. It is also very easy to assemble and disassemble the working electrode when needed. (C) 1999 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rapid and sensitive detection method for the determination of 5-fluorouracil(5-FU) in real samples such as human urine and bovine serum albumin (BSA) was described. A carbon fiber microdisk electrode was used to perform end-column amperometric detection in capillary zone electrophoresis. The detection limit was as low as 2.5x10(-7) M and the wider linear range for the concentration was between 5x10(-6) and 1x10(-4) M with a correlation coefficient of 0.995.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Promethazine and thioridazine were separated and detected by capillary electrophoresis with end-column amperometric detection. The influence of pH Value on oxidation potential, the peak current and the resolution were studied and the following conditions was selected: 0.03 M Na2HPO4 and 0.015 M citric acid at pH 3.0, detection potential at 1.10 V. The detection limits of these two substances were in the range of 10(-8) mol/l. The linear range spanned two to three orders of magnitude. This method was applied to the detection of promethazine and thioridazine spiked in urine. (C) 1999 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

4-Pyridyl hydroquinone on a platinum electrode adsorbs through the pyridine nitrogen forming stable self-assembled layers. The electrocatalytical oxidation of hydrazines was performed by the modified electrode. The overpotential of hydrazines was decreased markedly at the self-assembled monolayer (SAM) electrode. The mechanism of hydrazine oxidation was also investigated. Amperometric detection of hydrazine under zero potential (vs Ag\AgCI\sat. KCl) was exhibited by the SAM electrode used as an electrochemical detector in a flow system. (C) 1998 Elsevier Science S.A. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A procedure is described for the preparation of a tubular electrode by chemical deposition of platinum at the end of a fused-silica capillary. The properties of the electrode were tested under liquid chromatographic conditions, demonstrating that both the static and the dynamic behaviour of the detection system satisfy the requirements of capillary chromatographic separations and compare well with a wall-jet amperometric system and with UV photometric detection. The detection system described is easy to prepare and does not require any time-consuming positioning of the electrode system as it is integrated into the separation part of the apparatus. (C) 1998 Elsevier Science B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A poly(4-vinyl)pyridine (PVP)/Pd film electrode was constructed for the electrocatalytic detection of hydrazine. The preparation of the PVP/GC electrode was performed by electropolymerization of the monomer 4-vinylpyridine onto the surface of a glassy carbon electrode. Subsequently, palladium is electrodeposited onto the polymer modified electrode surface. The ion-exchange function of PVP polymer is helpful to this process in view of the tetrachlorapalladate anion. Compared with the Pd/GC electrode, the modified electrode displays a better mechanical stability in a flowing stream. The PVP/Pd film electrode exhibits higher sensitivity when detecting hydrazine with a detection limit of 0.026 ng (S/N=3).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chromatography-amperometric detection of nitrite with a polypyrrole modified glassy carbon electrode doped with tungstodiphosphate anion (Dawson-type P2W18O626-/PPy/GC electrode) based on its electrocatalytic reduction of nitrite is described. The cyclic and hydrodynamic voltammetry of nitrite at the P2W18O626-/PPy/GC electrode was studied. The factors affecting the detection of nitrite and the analytical performance of the modified electrode in flowing stream were investigated. The results show that the modified electrode has a good sensitivity (the limit of detection is 1 mu mol dm(-3)) and a satisfactory reproducibility (RSD = 3.78%, N = 21). The modified electrode was used in the chromatographic detection of nitrite spiked in the liquid from a tin of mushrooms and the mineralized spring water. It was found that the modified electrode exhibited good selectivity for nitrite.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A reversed-phase high-performance liquid chromatography with series dual glassy carbon electrodes for the amperometric detection of water-soluble menadione is described. The complex post-column derivatization reaction and the high background currents were avoided. The menadione sodium bisulfite was reduced at -0.3 V vs. SCE at the upstream (generator) electrode and oxidized at +0.2V vs. SCE at the downstream (collector) electrode. The mobile phase was 0.2moll(-1) HAc-NaAc aqueous buffer (pH 5.50) and 40% (v/v) methanol. The linear response was in the range of 35 ng to 15 mu g, with a detection Limit of 15 ng (S/N=3). The correlation coefficient was 0.9997 (n=6). The electrochemical detection with series dual electrodes has a higher selectivity for menadione (vitamin K-3) compound than with UV detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new immobilization material and an immobilization method for a glucose sensor with HEFc (hydroxyethylferrocene) as mediator is described. In the course of three months, the enzyme electrode shows almost no deterioration in its response characteristics. The response time is less than 30 s. The electrode has a wide linear range up to 10 mmol l(-1) with good repeatability. The kinetic parameters have also been calculated.