157 resultados para Polyamine Oxidase
Resumo:
An amperometric glucose biosensor was constructed based on a glassy carbon electrode modified with a Cobalt(II)hexacyanoferrate film which catalyzes electroreduction of hydrogen peroxide. Gelatin was used as immobilization matrix. Interference could be effectively eliminated by the combination of low detection potential with a Nafion coating. A low applied potential can avoid oxidation of interferences such as ascorbic acid, uric acid, p-acetyl-aminophenol, etc.. Nafion coating prevents interferences from access to the electrode surface by electrostatic repulsion. A wide linear range of detection was obtained. Analytical performance parameters are given and kinetic analysis discussed.
Resumo:
yA review with 44 references is presented on the development of sol-gel-based biosensor. The main discussions are devoted to the process, advantages and properties of sol-gel immobilization method, sol-gel optical biosensor and amperometric biosensor, also the trend in this field is forecasted.
Resumo:
Conductive polyaniline was found to have special marine antifouling property. The coating from conducting polyaniline and epoxy resin(or polyurethane) can last 6-9 months in Southern China sea, i.e., less than 10% of the coating surface was fouled during this period. The conducting polyaniline has special synergetic antifouling effect on other antifouling agents like cuprous oxide or 4, 4'-dichlorodiphenyltrichloroethane. The conductivity of the polyaniline was found to be extremely important for its antifouling effect. Moreover, employing aliphatic polyamine as solvent of emeraldine base and curing agent of epoxy resin, a new technique to process corrosion prevention coating containing emeraldine base was developed, therefrom the emeraldine base and epoxy resin was in molecular level blending. This technique was solvent free and extremely effective, i.e., only 1wt% of emeraldine base in the coating can have good corrosion prevention property.
Resumo:
A flow injection analysis detection method for glucose is presented which is based on the oxidation of glucose by glucose oxidase followed by chemiluminescent detection of hydrogen peroxide. Both glucose oxidase and hematin, a chemiluminescent reaction catalyst, were bulk-immobilized conveniently by direct mixing with carbon paste, which allows renewal of the electrode surface by simply polishing or cutting to expose a new and fully active surface in the case of fouling. Luminol in reagent solution passed through the flow cell and reacted with hydrogen peroxide produced by the enzyme reactor in the presence of the catalyst to yield light. An applied potential of -0.4 V avoided the electrode fouling effectively. The log-log plot of the emitted light intensity vs glucose concentration was linear over the range of 1-100 mmol L-1 with a correlation coefficient of 0.992. Application of this method to other chemiluminescent and bioluminescent systems is suggested. (C) 1999 Academic Press.
Resumo:
An acid-stable soybean-peroxidase biosensor was devel oped by immobilizing the enzyme in a sol-gel thin film. Methylene blue was used as a mediator because of its high electron-transfer efficiency. The sol-gel thin film and enzyme membrane were characterized by FT-IR, and the effects of pH, operating potential, and temperature were explored for optimum analytical performance by using the amperometric method. The H2O2 sensor exhibited a fast response (5 s), high sensitivity (27.5 mu A/mM), as well as good thermostability and long-term stability. In addition, the performance of the biosensor was investigated using flow-injection analysis (FIA).
Resumo:
A tyrosinase-based amperometric biosensor using a self-gelatinizable graft copolymer of poly(vinyl alcohol) with 4-vinylpyridine (PVA-g-PVP) as an immobilization matrix was constructed. The 4-vinylpyridine component of PVA-g-PVP enhances the adherence to a glassy carbon electrode surface. The content of 4-vinylpyridine in this immobilization matrix plays a key role in retaining the activity of tyrosinase. A simple, milder method was adopted by simply syringing the copolymer-tyrosinase aqueous solution on to the electrode surface and allowing water to evaporate at 4 degrees C in a refrigerator. Several parameters, including copolymer composition; pH, applied potential and enzyme membrane composition, ware optimized. The enzyme membrane composition can be varied to obtain higher sensitivity or a wider linear detection range. The biosensor was used for the determination of phenol, p-cresol and catechol. The biosensor exhibited excellent reproducibility, stability and sensitive response and can be used in flow injection analysis. The biosensor showed an extended linear range in hydrophilic organic solvents and it can be used in monitoring organic reaction processes. The analytical performance demonstrated this immobilization matrix is suitable for the immobilization of tyrosinase.
Resumo:
The matrix-assisted laser desorption ionization mass spectrometry (MALDI-TOF-MS) spectra of four enzymes (PLA, AEase, Fibrolase, L-a.a. oxidase) in Agkistrodon blomhoffii Ussurensis venom, were given and interpreted. The experiment data showed that MALDI-TOF-MS can be used directly in enzyme analysis with high sensitivity and rapidity. In addition, the results were better than those from sodium dodecyl sulfate-polyacrylamide.
Resumo:
(A) novel chemiluminescence (CL) system was evaluated for the determination of hydrogen peroxide, glucose and ascorbic acid based on hydrogen peroxide, which has a catalytic-cooxidative effect on the oxidation of luminol by KIO4. Hydrogen peroxide can be directly determined by luminol-KIO4 -H2O2 CL system. The detection limit was 3.0 x 10(-8) mol l(-1) and the calibration graph was linear over the range of 2.0 x 10(-7)-6.0 x 10(-4) mol l(-1). The relative standard deviation of H2O2 was 1.1% for 2.0 x 10(-6) mol l(-1) (N = 11). Glucose was indirectly determined through measuring the H2O2 generated by the oxidation of glucose in the presence of glucose oxidase at pH 7.6. The present method provides a source for H2O2, which, in turn, coupled with the luminol-KIO4-H2O2 CL reaction system. The CL was linearly correlated with glucose concentration of 0.6-110 mu g ml(-1). The relative standard deviation was 2.1% for 10 mu g ml(-1) (N = 11). Detection limit of glucose was 0.08 mu g ml(-1). Ascorbic acid was also indirectly determined by the suppression of luminol-KIO4-H2O2 CL system. The calibration curve was linear over the range of 1.0 x 10(-7)-1.0 x 10(-5) mol l(-1) of ascorbic acid. The relative standard deviation was 1.0% for 8.0 x 10(-7) mol l(-1) (N = 11). Detection limit of ascorbic acid was 6.0 x 10(=8) mol l(-1). These proposed methods have been applied to determine glucose, ascorbic acid in tablets and injection. (C) 1999 Elsevier Science B.V. All rights reserved.
Resumo:
用离子交换和凝胶过滤层析技术从长白山白眉蝮蛇蛇毒(A gkistrodon blom hoffii ussurensis)中分离得到了L氨基酸氧化酶(L-amino acid oxidase),经SDS-聚丙烯酰胺凝胶电泳(SDS-PAGE)和基体辅助激光解吸电离飞行时间质谱(MALDI-TOF-MS)鉴定,发现L-氨基酸氧化酶由两个不相等的亚基组成,一个亚基的分子量约为36000,另一个亚基分子量约为57000.以L-亮氨酸作为底物进行L-氨基酸氧化酶活力测定时发现,其反应的适宜PH值为45.5和89,紫外吸收光谱明显表现出核黄素蛋白的特征
Resumo:
利用同步荧光技术对长白山白眉蝮蛇蛇毒中纯化得到的4种酶:磷脂酶A2(phospholipase A2,PLA2)、精氨酸酯酶(arginine esterase,AEase)、纤溶酶(fibrinolytic enzyme,FEase)和L-氨基酸氧化酶(L-amino acid oxidase,L-a a oxidase)进行了研究. 结果表明:当Δλ=20nm时, 酶的荧光主要由酪氨酸(Tyr)残基所贡献; 当Δλ≥75nm时,酶的荧光主要由色氨酸(Try)所贡献.而且,长白山白眉蝮蛇蛇毒4种酶的Tyr和Trp残基所处的微环境并不相同.
Resumo:
A novel poly(vinyl alcohol) grafting 4-vinylpyridine self-gelatinizable copolymer was adapted to immobilize glucose oxidase. The reduction of hydrogen peroxide (H2O2) was detected at a Prussian Blue (PB) modified graphite electrode. A stable and sensitive glucose amperometric biosensor is described. The copolymer is a good biocompatible polymer in which the glucose oxidase retains high activity. Moreover, the copolymer can adhere firmly to the inorganic PB membrane. The sensor showed an apparent Michaelis-Menten constant of 18 +/- 0.2 mM and a maximum current density of 1.14 mu A cm(-2) mM(-1). The linear range is from 5 mu M to 4.5 mM glucose and the detection limit is 0.5. mu M glucose. The catalytic efficiency of PB for the reduction of H2O2 is higher than that for the oxidation of H2O2. Glucose concentrations in serum samples from healthy persons and diabetic patients were determined using the sensor. The results compared well with those provided by the hospital using a spectroscopy method.
Resumo:
A new type of sol-gel organic-inorganic hybrid material was developed and used for the production of biosensors. This material is composed of silica sol and a grafting copolymer of poly(vinyl alcohol) with 4-vinylpyridine. It prevents the cracking of conventional sol-gel-derived glasses and eliminates the swelling of the hydrogel. The optimum composition of the hybrid material was first examined, and then glucose oxidase was immobilized in this matrix to demonstrate its application. The characteristics of the biosensor were studied by cyclic voltammetry and chronoamperometry. The biosensor exhibited a series of good properties: high sensitivity (600 nA mmol(-1)L(-1)), short response time (11 s) and remarkable long-term stability in storage (at least 5 months). In addition, the characteristics of the second-generation biosensor with the use of tetrathiafulvalene as a mediator mere discussed.
Resumo:
A selenium-containing catalytic antibody (Se-4A4), prepared by converting reactive serine residues of a monoclonal antibody (4A4) raised against a GSH derivative into selenocysteines, acts as a mimic of cytosolic glutathione peroxidase (cGPX). To clarify the mechanism of action of this catalytic antibody, detailed studies on kinetic behaviour and biological activity were carried out. A rate of acceleration (k(cat)/K-m/k(uncat)) 10(7)-fold that of the uncatalytic reaction is observed. Under similar conditions, the turnover number (k(cat)) of Se-4A4 is 42% of that of the natural rabbit liver cGPX. The Se-4A4 reaction involves a Ping Pong mechanism, which is the same as that of the natural cGPX. The selenocysteine residue is located in the binding site of the antibody and is shown to be crucial for this activity. Of the thiol compounds tested, only GSH is able to serve as substrate for Se-4A4. It was demonstrated, using the free-radical-damage system (hypoxanthine/xanthine oxidase) of cardiac mitochondria, that Se-4A4 can protect mitochondria from free-radical damage at least 10(4)-fold more effectively than the natural cGPX.
Resumo:
The interaction between horseradish peroxidase (HRP) and the cryo-hydrogel was probed by using hydrazines which show high specificity of the reaction of the edge in the prosthetic heme of horseradish peroxidase. For comparison, the interaction of hydrazine with the horseradish peroxidase adsorbed on graphite electrode was also carried out by using steady-state response of the enzyme electrode and cyclic voltammetry. In order to obtain a proper explanation of the kinetic parameters for the enzymatic reaction, the theoretical expressions of I-max and K-M' in the Michaelis-Menten equation for the experimental system were provided. (C) 1997 Elsevier Science B.V.
Resumo:
The interfacial characteristics of poly-L-lysine (PL) attached on self-assembled monolayers (SAMs) of 3-mercaptopropionic acid (MPA) were studied by an electrochemical method. The results indicated that PL\MPA layer inhibited partly the diffusion process of redox species in solution, and the electrode surface behaved like a microelectrode array. Its permeation effect was also strongly affected by Mg2+. The more Mg2+ ions were added into the electrolyte solution, the greater the difficulty with which the electron transfer of potassium ferricyanide took place. The three different conformations of PL on the electrode surface had different influences on the electron transfer processes of ferricyanide. PL in random coil state hindered most strongly the electron transfer behavior of ferricyanide,while the alpha-helical PL had nearly no effect and the effect of the beta-sheet state PL was intermediate of these. (C) 1997 Elsevier Science S.A.