222 resultados para LC-APCI-MS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present the first measurements of identified hadron production, azimuthal anisotropy, and pion interferometry from Au + Au collisions below the nominal injection energy at the BNL Relativistic Heavy-Ion Collider (RHIC) facility. The data were collected using the large acceptance solenoidal tracker at RHIC (STAR) detector at root s(NN) = 9.2 GeV from a test run of the collider in the year 2008. Midrapidity results on multiplicity density dN/dy in rapidity y, average transverse momentum < p(T)>, particle ratios, elliptic flow, and Hanbury-Brown-Twiss (HBT) radii are consistent with the corresponding results at similar root s(NN) from fixed-target experiments. Directed flow measurements are presented for both midrapidity and forward-rapidity regions. Furthermore the collision centrality dependence of identified particle dN/dy, < p(T)>, and particle ratios are discussed. These results also demonstrate that the capabilities of the STAR detector, although optimized for root s(NN) = 200 GeV, are suitable for the proposed QCD critical-point search and exploration of the QCD phase diagram at RHIC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nuclear collisions recreate conditions in the universe microseconds after the Big Bang. Only a very small fraction of the emitted fragments are light nuclei, but these states are of fundamental interest. We report the observation of antihypertritons-comprising an antiproton, an antineutron, and an antilambda hyperon-produced by colliding gold nuclei at high energy. Our analysis yields 70 +/- 17 antihypertritons (3/Lambda(H) over bar) and 157 +/- 30 hypertritons (H-3(Lambda)). The measured yields of H-3(Lambda) (3/Lambda(H) over bar) and He-3 ((3)(He) over bar) are similar, suggesting an equilibrium in coordinate and momentum space populations of up, down, and strange quarks and antiquarks, unlike the pattern observed at lower collision energies. The production and properties of antinuclei, and of nuclei containing strange quarks, have implications spanning nuclear and particle physics, astrophysics, and cosmology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present measurements of the charge balance function, from the charged particles, for diverse pseudorapidity and transverse momentum ranges in Au + Au collisions at root S-NN = 200 GeV using the STAR detector at RHIC. We observe that the balance function is boost-invariant within the pseudorapidity coverage vertical bar-1.3, 1.3 vertical bar. The balance function properly scaled by the width of the observed pseudorapidity window does not depend on the position or size of the pseudorapidity window. This scaling property also holds for particles in different transverse momentum ranges. In addition, we find that the width of the balance function decreases monotonically with increasing transverse momentum for all centrality classes. (c) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present the multiplicity and pseudorapidity distributions of photons produced in Au + Au and Cu + Cu collisions at root(NN)-N-s = 62.4 and 200 GeV. The photons are measured in the region -3.7 < eta < -2.3 using the photon Multiplicity detector in the STAR experiment at RHIC. The number of photons produced per average number of participating nucleon pairs increases with the beam energy and is independent of (lie collision centrality. For collisions with similar average numbers of participating nucleons the photon multiplicities are observed to be similar for An + Au and Cu + Cu collisions at a given beam energy. The ratios of the number of charged particles to photons in the measured pseudorapidity range are found to be 1.4 +/- 0.1 and 1.2 +/- 0.1 for root(NN)-N-s = 62.4 and 200 GeV, respectively. The energy dependence of this ratio could reflect varying contributions from baryons to charged particles, while mesons are the dominant contributors to photon production in the given kinematic region. The photon pseudorapidity distributions normalized by average number of participating nucleon pairs, when plotted as a function of eta-Y-beam, are found to follow a longitudinal scaling independent of centrality and colliding ion species at both beam energies. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

这篇论文里,我们对基于ms Windows的微机γ谱分析程序的数学原理,算法及程序设计进行了阐述;同时,我们也介绍了测试结果,此结果表明了拟合过程的高效性,高稳定性与准确性,并且,程序计算出的峰面积也是可接受的。 在第一部分里,全面阐述了数学原理与算法,包括由M. A. Mariscotti设计且已衍生出许多新算法的叫作DIFDIF的找峰算法,由BFGS方法实现的以χ2为拟合优值的拟合过程,在求峰下净面积及进行系统刻度中需要使用的公式等等。这些内客构成了γ谱分析程序设计哲学的核心,也是本论文的重点。 第二章里,我们一方面概括地介绍了基于面向对象思想的从系统分析到设计整个过程的系统开发文档;另一方面,我们也介绍了一些有用的程序片段,它们或者关于C++或MS Windows程序设计方法,或者关于运行时间错的处理。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

建立了气相色谱-质谱-选择离子监测(GC-MS-SIM)同时测定土壤中10种农药(三嗪类除草剂、酰胺类除草剂和有机氯农药)的多残留分析方法.样品采用正己烷/丙酮(1:1,V/V)超声提取、氟罗里硅土柱层析净化、GC-MS-SIM测定.10种农药在0.01(0.02)—1.0(2.0)mg.l-1范围内线性良好,相关系数介于0.9963—0.9998之间;在10,50和250ng.g-1添加水平下,平均回收率介于81%—117%之间,相对标准偏差均小于14.4%;方法检出限达到ppb至sub-ppb级(0.1—1.3ng.g-1).将此方法应用于辽宁省不同性质土壤中70个实际土壤样品的分析,阿特拉津、乙草胺、六氯苯、丁草胺、狄氏剂和艾氏剂有检出,该法对不同性质土壤具有广泛适用性.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A high-throughput screening system for secondary catalyst libraries has been developed by incorporation of an 80-pass reactor and a quantified multistream mass spectrometer screening (MSMSS) technique. With a low-melting alloy as the heating medium, a uniform reaction temperature could be obtained in the multistream reactor (maximum temperature differences are less than 1 K at 673 K). Quantification of the results was realized by combination of a gas chromatogram with the MSMSS, which could provide the product selectivities of each catalyst in a heterogeneous catalyst library. Because the catalyst loading of each reaction tube is comparable to that of the conventional microreaction system and because the parallel reactions could be operated under identical conditions (homogeneous temperature, same pressure and WHSV), the reaction results of a promising catalyst selected from the library could be reasonably applied to the further scale-up of the system. The aldol condensation of acetone, with obvious differences in the product distribution over different kind of catalysts, was selected as a model reaction to validate the screening system.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

以镉胁迫花生为原料,建立了液相色谱-电喷雾电离质谱联用仪测定花生中的植物螯合肽的LC-MS方法。以C18反相柱为分析柱,1%三氟乙酸、乙腈为梯度洗脱淋洗液,能够检测出花生中的植物螯合肽。在本实验条件下,检出限为0.2 mg/L;线性范围在0.50~20.0 mg/L(r≥0.9974);回收率大于80%。方法灵敏度高,实用性强。应用本方法对实际花生样品中的PC4进行了定量分析。初步证实了花生中存在丙氨酸类植物螯合肽。结果表明,受镉胁迫的花生中均检出不同浓度的PC4。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new method for the sensitive determination of amino acids and peptides using the tagging reagent 2-(9-carbazole)-ethyl chloroformate (CEOC) with fluorescence (FL) detection has been developed. Identification of derivatives was carried out by liquid chromotography mass spectrometry. The chromophore in the 2-(9-fluorenyl)-ethyl chloroformate (FMOC) reagent was replaced by carbazole, which resulted in a sensitive fluorescence lerivatizing agent CEOC. CEOC can easily and quickly label peptides and amino acids. Derivatives are stable enough to be efficiently analyzed by high-performance liquid chromatography. Studies on derivatization demonstrate excellent derivative yields over the pH range 8.8-10.0. Maximal yields close to 100% are observed with three- to fourfold molar reagent excess. Derivatives exhibit strong fluorescence and allow direct injection of the reaction mixture with no significant disturbance from the major fluorescent reagent degradation by-products, such as 2(9-carbazole)-ethanol and bis-(2-(9-carbazole)-ethyl) carbonate. In addition, the detection responses for CEOC derivatives are compared to those obtained with FMOC. The ratios AC(CEOC)/AC(FMOC) = 1.00-1.82 for fluorescence (FL) response and AC'(CEOC)/AC'(FMOC) = 1.00-1.21 for ultraviolet (UV) response are observed (here, AC and AC' are, respectively, FL and UV F response). Separation of the derivatized peptides and amino acids has been optimized on a Hypersil BDS C18 column. Excellent linear responses are observed. This method was used successfully to analyze protein hydrolysates from wool and from direct-derivatized beer. (C) 2003 Elsevier Science (USA). All rights reserved.