251 resultados para AMNIOTIC MEMBRANE TRANSPLANTATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The interaction of lanthanide ions with a supported bilayer lipid (1,2-dimyristoyl-sn-glycero-3-phosphatidylcholine) membrane (sBLM) was investigated by cyclic voltammetry and ac impedance spectroscopy in this paper, Lanthanide can affect the conformation of the supported bilayer lipid membrane and cause pore formation. Through the pores, Fe(CN)(6)(3) (4) can reach the electrode surface and show its redox behaviour. Furthermore the redox currents or Fe(CN)(6)(3) (4) increased with increasing concentration of lanthanides and leveled off at 1.2 muM for Eu3+. The interaction ability of three lanthanides with sBLM follows the sequence: Eu3+ > Tb3+ > La3+.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adsorption of a monolayer of didecanoyl-L-alpha-phosphatidylcholine (DDPC) from dispersions of small unilamellar vesicles onto hydrophobic surfaces was investigated by mean of cyclic voltammetry and impedance spectroscopy. The hydrophobic surfaces were self-assembled monolayers of 2-mereapto-3-n-octylthiophene (MOT) on gold. One characteristic of the MOT monolayer is its permeability to organic molecules in aqueous solution, thus providing a more energetically favorable hydrophobic surface for the addition of phospholipid vesicles. The kinetics of the lipid monolayer formation were followed by measuring the time-dependent interfacial capacitance. Unusual values of thickness and capacitance of the MOT/ DDPC bilayers were observed. An interdigitating conformation of the bilayer structure was proposed to interpret the experimental results, The horseradish peroxidase reconstituted into the bilayer demonstrated the expected protein activity, showing practical use in research and in biosensor application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The acid-base equilibrium of self-assembly monolayer(SAM) of mercaptopropionic acid on gold electrode was studied by capacitance titration. The change of capacitance was due to protonation and deprotonation of the modified electrode surface. This method can be used to measure pH value in solution and capacitance of solid/liquid on SAMs surface synchronously. The shift of pK(a) was observed during the experiment as previous reports. The factors that affect the capacitance measurement were discussed in detail.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present paper reports the channel behavior of gramicidin in mercaptan self-assembled monolayer on the surface of the gold electrode by using the electrochemical method. The current responses to K+ ions and the electrode potential for the gold electrodes modified with self-assembled mercaptan monolayer incorporating and not incorporating gramicidin D were compared. The results firstly indicated that gramicidin D molecules can be incorporated into the mercaptan monolayer assembled on the surface of the gold electrode and form monovalent ion channel. A mechanism of the phenomenon was proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrochemical SO2 sensor worked at the fixed potential and prepared with Nafion membrane as the solid electrolyte was studied. It v as observed that after Nafion membrane, was treated with H2SO4, the water-preserving ability of the membrane was increased. In turn, the performance of the sensor became stable. After lifetime test for 4 months, the performance of the sensor deceased slightly, Thus this kind of sensor may become a gas sensor for the practical application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Blend modified polyimide (PI) hollow fiber membranes were used in vapor permeation for gas phase dehydration of ethanol. Dry air sweeping operation was used and the dry air was supplied by a dehumidification membrane module of compressed air. An integrated membrane process was composed. The effects of some factors, such as the modification of membrane materials, the humidity and current velocity of sweeping air, the operation temperature, on the efficiency of dehydration were discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The based membrane extraction of Th4+ and Yb3+ was studied in HBTMPP-heptane using a hollow fibber membrane. The separation method of Th4+ and Yb3+ was proposed by kinetics competition. The separation operation of Th4+ and Yb3+ mixture was carried out by two successive extraction and stripping simultaneously. The concentration ratio of Th4+ to Yb3+ is 16.74 in the stripping solution. The recovery and purity of Th4+ are 71.6% and 95.74% respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The interaction of microperoxidase-11 (MP11) with cationic lipid vesicles of didodecyldimethylammonium bromide (DDAB) induces an alpha -helical conformation from random coil conformations in solution and this change then makes heme macrocycle more distorted. DDAB-induced MP11 conformations were investigated by cyclic votammetry (CV), circular dichroism (CD) and UV-vis spectrometry. All results indicate that the binding of MP11 in solution to DDAB vesicles and the ordered structure formation are driven by mostly electrostatic interaction between negatively charged residues in the undecapeptide and positively charged lipid headgroups on the membrane surface. Upon binding to DDAB, its half-peak potential was also changed. The mechanism of the interaction between MP11 and DDAB was also discussed. (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Extraction and separation of Eu3+ and Zn2+ in sulfuric acid solution was investigated by hollow fiber membrane with cyanex 302 (bis (2,4,4-trimethylpentyl) monothiophosphinic acid) in counter-currently circulating operation. Reaction mechanism of membrane extraction and effect of extractant concentration and H+ concentration in aqueous phase on the mass transfer coefficient were discussed. It can be concluded that Zn2+ can be extracted completely from Eu3+ sulfate solution according to the kinetics competing difference. In one extractor process, extraction percentage of Zn2+ was not completely and Eu3+ was not extracted. Extraction percentage of Zn2+ reached 94.92%, but Eu3+ only reached 8.59% after 100 minutes extraction in two series connectors and that of Zn2+ and Eu3+ reached 99.9% and 6.53% respectively after 40 minutes extraction in three series connectors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ferricyanide anion has usually been used as a marker of ion-channel sensors. In this work we first found that ferricyanide, itself, can act as a stimulus to regulate the permeability of sBLM prepared from didodecyldimethylammonium bromide (a kind of synthetic lipid) on a GC electrode. We used cyclic voltammetry and a.c. impedance to investigate this phenomenon. The interaction between sBLM and ferricyanide concerns time. Furthermore, we developed a sensor for ferricyanide anion. The ion-channel sensor is highly sensitive. It can detect ferricyanide concentration as low as 5 muM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sodium sulfonate-functionalized polyether ether ketone)s derived from Bisphenol A with a degree of sulfonation up to 2.0 were synthesized by aromatic nucleophilic polycondensation of various amounts of 5,5-carbonylbis(2-fluorobenzenesulfonate) (1), 4,4'-diflurobenzophenone (2) and Bisphenol A (2). Copolymers showed excellent thermal stability and good mechanical properties. The selectivity of water vapor over nitrogen of membranes prepared from copolymers 3a and 3h was determined to be 3.43 x 10(6) and 1.05 x 10(7), respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method was developed for the determination of lanthanum in the cytoplasm of human erythrocytes after they were incubated in lanthanum nitrate or citrate solutions. The lanthanum concentration in the cytoplasm of incubated erythrocytes is much higher than that in normal erythrocytes. It is suggested lanthanum can transport through the membrane of erythrocyte in vitro. Solutions containing chelator are unsuitable to be washing buffer in the investigation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel type of potassium sensor based on the capacitance change of valinomycin-incorporated bilayer supported on a gold electrode has been developed and characterized. The lipid membrane was Formed by painted method and monitored simultaneously by capacitance variation. The capacitance of the electrode-supported membrane was found to be modulated by different concentrations of K+. Investigating the capacitance change allows a simple and specific technique for the measurement of potassium ion in solution. Especially, the homemade capacitance meter is, to our knowledge, used to monitor the bilayer membrane formation and detect K+ for the first time. It has been proved that this capacitance measurement is a very useful technique because it is simple and sensitive compared to the other methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrochemistry at the liquid/liquid and liquid/membrane interface has been developed recently. It can be used for a new kind of electrochemical detector and sensor. Some new aspects of the field in this laboratory are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Separation of Ce(IV) and RE(III) was investigated by hollow fiber membrane-based extraction with contercurrent recirculating operation. The mass transfer coefficients of Ce(IV) and RE(III) and the effective factors to them were tested. The results show the mass transfer coefficient of Ce(IV) is larger than that of RE(III), and their mass transfer mechanism is different. The mass transfer of Ce(IV) was controlled by the resistance in water critical layer due to its more rapid interfacial reaction rate and larger distribution coefficient, which was different from RE(III) mass transfer with a slow interfacial reaction rate and small distribution coefficient. Ce(IV) was separated from the mixed solution of Ce(IV) and RE(III) by means of the difference of their mass transfer rates.