Ion-channel sensing of ferricyanide anion based on a supported bilayer lipid membrane


Autoria(s): Han XJ; Wang E
Data(s)

2001

Resumo

Ferricyanide anion has usually been used as a marker of ion-channel sensors. In this work we first found that ferricyanide, itself, can act as a stimulus to regulate the permeability of sBLM prepared from didodecyldimethylammonium bromide (a kind of synthetic lipid) on a GC electrode. We used cyclic voltammetry and a.c. impedance to investigate this phenomenon. The interaction between sBLM and ferricyanide concerns time. Furthermore, we developed a sensor for ferricyanide anion. The ion-channel sensor is highly sensitive. It can detect ferricyanide concentration as low as 5 muM.

Identificador

http://202.98.16.49/handle/322003/20525

http://www.irgrid.ac.cn/handle/1471x/154997

Idioma(s)

英语

Fonte

Han XJ;Wang E.Ion-channel sensing of ferricyanide anion based on a supported bilayer lipid membrane,ANALYTICAL SCIENCES,2001,17(10):1171-1174

Palavras-Chave #CYCLIC VOLTAMMETRY #MONOLAYER #SENSORS #ELECTRODE #IMPEDANCE #BLM
Tipo

期刊论文