367 resultados para radioactive C-9-ion beam
Resumo:
A pilot experiment of mass measurement was performed at CSRe with the method of isochronous mass spectrometry. The secondary fragments produced via RIBLL2 with the primary beam of 400 MeV/u, Ar-36 delivered by CSRm were injected into CSRe. The revolution periods of the stored ions, which depend on the mass-to-charge ratios of the stored ions, were measured with a time-of-flight detector system. The results show that the mass resolution around 8 x 10(-6) for Delta m/m is achieved.
Resumo:
The construction and commissioning of HIRFL-CSR were finished in 2007. From 2000 to 2005 the subsystem and key devices of CSR were successfully fabricated, such as magnet, power supply, UHV system, e-cooler, electric-static deflector with the septum of 0.1 mm, and the fast-pulse kicker with the rise time of 150 ns. After that the CSR commissioning activities were performed in 2006 and 2007, including the accumulation of those heavy ions of C, Ar, Kr and Xe by the combination of stripping injection (STI) or multiple multi-turn injection (MMI) and e-cooling with a hollow e-beam, wide energy-range synchrotron ramping by changing the RF harmonic-number at mid-energy, the beam stacking in the experimental ring CSRe, the RIBs mass-measurement with the isochronous-mode in CSRe by using the time-of-flight method, and the ion beam slow-extraction from CSRm.
Resumo:
Purpose: To determine the effects of carbon ion beams with five different linear energy transfer (LET) values on adventitious shoots from in vitro leaf explants of Saintpaulia ionahta Mauve cultivar with regard to tissue increase, shoots differentiation and morphology changes in the shoots. Materials and methods: In vitro leaf explant samples were irradiated with carbon ion beams with LET values in the range of 31 similar to 151 keV/mu m or 8 MeV of X-rays (LET 0.2 keV/mu m) at different doses. Fresh weight increase, surviving fraction and percentage of the explants with regenerated malformed shoots in all the irradiated leaf explants were statistically analysed. Results: The fresh weight increase (FWI) and surviving fraction (SF) decreased dramatically with increasing LET at the same doses. In addition, malformed shoots, including curliness, carnification, nicks and chlorophyll deficiency, occurred in both carbon ion beam and X-ray irradiations. The induction frequency with the former, however, was far more than that with the X-rays. Conclusions: This work demonstrated the LET dependence of the relative biological effectiveness (RBE) of tissue culture of Saintpaulia ionahta according to 50% FWI and 50% SF. After irradiating leaf explants with 5 Gy of a 221 MeV carbon ion beam having a LET value of 96 keV/mu m throughout the sample, a chlorophyll-deficient (CD) mutant, which could transmit the character of chlorophyll deficiency to its progeny through three continuous tissue culture cycles, and plantlets with other malformations were obtained.
Resumo:
Uranium ion beams were produced from electron cyclotron resonance (ECR) ion sources by sputtering method this year at the Institute of Modern Physics. At first, we chose the Lanzhou ECR No. 3 ion source to implement the production experiment of U ion beams. Finally, 11 e mu A of U28+, 5 e mu A of U32+, and 1.5 e mu A of U35+ were obtained. A U26+ ion beam produced by the LECR2 ion source was accelerated successfully by the cyclotron. This means that the Heavy Ion Research Facility in Lanzhou (HIRFL) has accomplished the acceleration of the ion beam of the heaviest element according to the designed parameters. The Lanzhou ECR ion source No. 2 (LECR2), which was built in 1997, has served the HIRFL for eight years and needed to be upgraded to provide more intense high charge state ion beams for HIRFL cooling storage ring. We started the upgrading project of LECR2 last year, and the modified design just has been finished. (c) 2006 American Institute of Physics.
Resumo:
To meet the requirements of providing high-intensity heavy ion beams the direct plasma injection scheme (DPIS) was proposed by a RIKEN-CNS-TIT collaboration. In this scheme a radio frequency quadrupole (RFQ) was joined directly with the laser ion source (LIS) without a low-energy beam transport (LEBT) line. To find the best design of the RFQ that will have short length, high transmission efficiency and small emittance growth, beam dynamics designs with equipartitioning design strategy and with matched-only design strategy have been performed, and a comparison of their results has also been done. Impacts of the input beam parameters on transmission efficiency are presented, too. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
The total reaction cross section (1724 +/- 93 mb) of B-17 at the energy of 43.7 A MeV on C target has been measured by using the transmission method at the Radioactive Ion Beam Line in Lanzhou (RIBLL). Assuming B-17 consists of a core B-15 plus two halo neutrons, the total cross section of B-17 on C target was calculated with the zero-range Glauber model, where double Gaussian density distributions and Gaussian plus HO density distributions were used. It can fit the experimental data very well. The characteristic of halo structure for B-17 was found with a large diffusion of the neutrons density distribution.
Resumo:
The status of heavy-ion cancer therapy has been reviewed. The existing and constructing heavy-ion beam facilities for cancer therapy in the world are introduced. The first clinical trials of superficially placed tumor therapy at heavy ion research facility in Lanzhou (HIRFL) are presented.
Resumo:
The reaction cross section of B-17 on C-12 target at (43.7 +/- 2.4) MeV/u has been measured at the Radioactive Ion Beam Line in Lanzhou (RIBLL). The root-mean-square matter radius (R-rms) was deduced to be (2.92 +/- 0.10) fm, while the R-rms of the core and the valence neutron distribution are 2.28 fm and 5.98 fm respectively. Assuming a "core plus 2n" structure in B-17, the mixed configuration of (2s(1/2)) and (1d(5/2)) of the valence neutrons is studied and the s-wave spectroscopic factor is found to be (80 +/- 21)%.
Resumo:
Large-sized CsI (Tl) single crystals, similar to phi 100 mm x 350 mm, have been grown successfully, and this CsI(Tl) coupled with PD has been successfully utilized at RIBLL (the Radioactive Ion Beam Line in Lanzhou) to measure the energy of heavy ions as a stopping detector. The performances of CsI(Tl) detector coupled with PD and APD have been tested and compared, including the temperature dependence of scintillating light yield
Resumo:
The aim of this study is to investigate the effects of different doses of 100 MeV/u carbon ions on sweet sorghum seeds in order to improve crop yields and their sugar content. After irradiation, seeds were germinated and grown to 30 days, and others were sown in the field. At the end of harvesting season all planted seeds were picked separately and M2 generations obtained. The differences among the treatments were examined using the RAPID procedure. In the study done by using 38 primers; according to the amplification results, the differences among the various doses treatment were shown.
Resumo:
The neutron-rich nucleus Li-11 is separated by the radioactive ion beam line RIBLL at HIRFL from the breakup of 50MeV/u C-13 on Be target. The total reaction cross sections for Li-11 at energies range from 25 to 45MeV/u on Si target have been measured by using the transmission method. The experimental data at high and low energies can be fitted well by Glauber model using two Gauss density distribution. The matter radius of Li-11 was also deduced.
Resumo:
A recoil separator Wien-filter which was developed for the Radioactive Ion Beam Line in Lanzhou (RIBLL) as an extension is described. It consists of 2 quadruple triplets and a standard Wien-filter. It was designed for study of the fusion-evaporation reactions. The overall design, background suppression, the transmission efficiency, the angular acceptance and the momentum acceptance have been described. All the performances fulfil the designed requirements. Based on the test results, with some modifications the investigations of the nuclei with Z <= 110 and the drip-line nuclei in the medium-heavy mass region can be carried out with this facility.
Resumo:
A transverse field gas ionization chamber as Delta E detector at the Radioactive Ion Beam Line in Lanzhou (RIBLL) is described. A high detection efficiency and long plateau are achieved with the mixed gas Ar(80%)+CO2(20%). The energy resolution is 3.25% for 4.94MeV alpha particle. This ionization chamber has been tested in the experiment with 50MeV/u Ni-58 bombarding Ta at RIBLL. All the fragments can be identified clearly by the ionization chamber.
Resumo:
Background. The purpose of this study was to investigate whether adenovirus-mediated p53 transfer could sensitize hepatocellular carcinoma to heavy-ion irradiation. Methods. HepG2 cells were preexposed to a C-12(6+) beam, and then infected with replication-deficient adenovirus recombinant vectors containing human wild-type p53 (AdCMV-p53) (C-12(6+) irradiation + AdCMV-p53 infection). The survival fraction was determined by clonogenic assay. The cell cycle, cell apoptosis, and p53 expression were monitored by flow cytometric analysis. Results. p53 expression in C-12(6+) irradiation + AdCMV-p53 infection groups was markedly higher than that in C-12(6+) irradiation only groups (P < 0.05), suggesting that the preexposure to the C-12(6+) beam promoted the expression of exogenous p53 in HepG2 cells infected with AdCMV-p53 only. The G(1)-phase arrest and cell apoptosis in the C-12(6+) irradiation + AdCMV-p53 infection groups were significantly more than those in the C-12(6+) irradiated groups (P < 0.05). The survival fractions of the C-12(6+) irradiation + AdCMV-p53 infection groups decreased by 30%-49% compared with those of the C-12(6+) beam-irradiated only groups (P < 0.05). Conclusions. Adenovirus-mediated p53 gene transfer can promote G(1)-phase arrest and cell apoptosis, thus sensitizing hepatocellular carcinoma cells to heavy-ion irradiation.
Resumo:
With the construction of the new Radioactive Ion Beam Line in Lanzhou (RIBLL II) which connects the CSRm and the CSRe, an experimental setup for physics research is highly required. A large area neutron detection wall is the main part of the setup. This paper introduced the detection principle of the neutron detection wall and the Monte-Carlo simulation of its design under the environment of the Geant4 toolkit. We presented the final design with the optimized parameters and the performance of the wall.