193 resultados para Sensitive barrier
Resumo:
The shell correction is proposed in the improved isospin dependent quantum molecular dynamics (Im-IQMD) model, which plays an important role in heavy-ion fusion reactions near Coulomb barrier. By using the ImIQMD model, the static and dynamical fusion barriers, dynamical barrier distribution in the fusion reactions are analyzed systematically. The fusion and capture excitation functions for a series of reaction systems are calculated and compared with experimental data. It is found that the fusion cross sections for neutron-rich systems increase obviously, and the strong shell effects of two colliding nuclei result in a decrease of the fusion cross sections at the sub-barrier energies. The lowering of the dynamical fusion barriers favors the enhancement of the sub-barrier fusion cross sections, which is related to the nucleon transfer and the neck formation in the fusion reactions.
Resumo:
Multi-hit 3-layer delay-line anode (Hexanode) has an increased ability to detect multi-hit events in a collision experiment. Coupled with a pair of micro-channel plates, it can provide position information of the particles even if the particles arrive at the same time or within small time dwell. But it suffers from some ambiguous outputs and signal losses due to timing order and triggering thresholds etc. We have developed a signal reconstruction program to correct those events. After the program correction, the dead time only exists when 2 paxticles arrive at the same time and the same position within a much smaller range. With the combination of Hexanode and the program, the experimental efficiencies will be greatly improved in near threshold double ionization on He collisions.
Resumo:
By means of the improved quantum molecular dynamics model, the incident energy dependent dynamical fusion potential barriers for heavy nucleus reaction systems are investigated. It is found that with decrease of incident energy the lowest dynamic barrier is obtained which approaches to the adiabatic static barrier and with increase of the incident energy the dynamic barrier goes up to the diabatic static barrier. Based on the dynamical study a microscopic understanding of the extra-push in fusion reactions of heavy systems and a new explanation of tunneling process for the fusion at the incident energy below the static and above the lowest dynamic barrier are presented. In order to understand the energy dependence of the dynamical barrier we also pay a great attention to study the neck formation and shape deformation during the dynamic lowering of the barrier.
Resumo:
The cross-section ratios of double-, triple-, quadruple-, and the total multi-electron processes to the single electron capture process sigma(DE)/sigma(SC), sigma(TE)/sigma(SC), sigma(QE)/sigma(SC) and sigma(ME)/sigma(SC)) as well as the relative ratios among reaction channels in double-electron active, triple-electron active and quadruple- electron active are measured in C-13(6+) -Ne collision in the energy region of 4.15-11.08 keV/u by employing position-sensitive and time-of-flight coincident techniques. It is determined that the cross-section ratios sigma(DE)/sigma(SC), sigma(TE)/sigma(SC), sigma(QE)/sigma(SC) and sigma(ME)/sigma(SC) are approximately the constants of 0.20 +/- 0.03, 0.16 +/- 0.04, 0.06 +/- 0.02 and 0.42 +/- 0.05. These values are obviously smaller than the predictions of the molecular Coulomb over-the-barrier model (MCBM) [J. Phys. B 23 (1990) 4293], the extended classical over-the-barrier model (ECBM) [J. Phys. B 19 (1986) 2925] and the semiempirical scaling laws (SL) [Phys. Rev. A 54 (1996) 4127]. However, the relative ratios among partial processes of DE, TE and QE are found to depend on collision energy, which suggests that the collision dynamics depends on the collision velocity. The limitation of velocity-independent character of ECBM, MCBM and SL is undoubtedly shown.
Resumo:
In this paper, to design a new preamplifier for optimum performances with charged-particle or heavy-ion detectors, the CMOS FET is implemented as a feedback capacitor C-fp, so that the entire system should be built only with MOSFET. This work is a revolution design because to realize an ASIC for a preamplifier circuit, the capacitor will also be included. We succeed after a simulation to maintain a rise time less than 3 ns, the output resistance less than 94 Omega and the linearity almost good.
Resumo:
In this paper, the design and analysis of a new low noise charge sensitive preamplifier for silicon strip, Si(Li), CdZnTe and CsI detectors etc. with switch control feedback resistance were described, the entire system to be built using the CMOS transistors. The circuit configuration of the CSP proposed in this paper can be adopted to develop CMOS-based Application Specific Integrated Circuit further for Front End Electronics of read-out system of nuclear physics, particle physics and astrophysics research, etc. This work is an implemented design that we succeed after a simulation to obtain a rise time less than 3ns, the output resistance less than 94 Omega and the linearity almost good.
Resumo:
提出了一种由DMOS场效应管构成的电荷灵敏前置放大器,可用于硅,Si(Li),CdZnTe及CsI探测器。该前置放大器采用不同于传统的阻容反馈式的电路结构,完全使用MOS管搭建,该前放的设计完成为设计实现ASIC电路准备了技术基础。由Multisi m仿真结果看出该电荷灵敏前置放大器输出信号上升时间小于15ns,并且具有很好的稳定性。