112 resultados para Reproducibility


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This dissertation systematically depicted and improved the application of Independent Component Analysis (ICA) to Functional Magnetic Resonance Imaging (fMRI), following the logic of verification, improvement, extension, and application. The concept of “reproducibility” was the philosophy throughout its four concluded studies. In the “verification” study, ICA was applied to the resting-state fMRI data, verified the resultant components with reproducibility, and examined the consistency of the results from ICA and traditional “seed voxel” method. At the meantime, the limitation of ICA application on fMRI data analysis was presented. In the “improvement” study, an improved ICA algorithm based on reproducibility, RAICAR, was developed to aid some of the limitations of ICA application. RAICAR was able to rank ICA components by reproducibility, determine the number of reliable components, and obtain more stable results. RAICAR provided useful tools for validation and interpretation of ICA results. In the “extension” study, RAICAR as well as the concept of “reproducibility” was extended to multi-subject ICA analysis, and gRAICAR algorithm was developed. gRAICAR allows some variation across subjects, examining common components among subjects. gRAICAR is also capable to detect potential subject grouping on some components. It is a new way for exploratory group analysis on fMRI. In the “application” study, two newly developed methods, RAICAR and gRAICAR, were used to investigate the effect of early music training on the brain mechanism of memory and learning. The results showed brain mechanism difference in memory retrieval and learning process between two groups of subjects. This study also verified the usefulness and importance of the new methods.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple method, based on the technique of capillary column switching-back flushing, has been developed for the detailed analysis of aromatic compounds in gasoline. The sample was first separated on a 30-m long OV-2330 polar precolumn and then backflushed onto a nonpolar analytical column. The early eluting components from the precolumn and the components of interest (aromatic compounds plus heavier compounds) eluting from the analytical column are all directed to the same flame ionization detection system through a T piece, which permits the quantitative analysis of aromatic hydrocarbons in gasoline by a normalization method using correcting factors. The switching time window of the method is +/-5 s, resulting in easier operation and higher reliability. The reproducibility of the quantitative analysis was less than or equal to3% RSD for real gasoline samples. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Inexpensive and permanently modified poly(methyl methacrylate)(PMMA) microchips were fabricated by an injection-molding process. A novel sealing method for plastic microchips at room temperature was introduced. Run-to-run and chip-to-chip reproducibility was good, with relative standard deviation values between 1-3% for the run-to-run and less than 2.1% for the chip-to-chip comparisons. Acrylonitrile-butadiene-styrene (ABS) was used as an additive in PMMA substrates. The proportions of PMMA and ABS were optimized. ABS may be considered as a modifier, which obviously improved some characteristics of the microchip, such as the hydrophilicity and the electro-osmotic flow (EOF). The detection limit of Rhodamine 6G dye for the modified microchip on the home-made microchip analyzer showed a dramatic 100-fold improvement over that for the unmodified PMMA chip. A detection limit of the order of 10(-20) mole has been achieved for each injected phiX-174/HaeIII DNA fragment with the baseline separation between 271 and 281 bp, and fast separation of 11 DNA restriction fragments within 180 seconds. Analysis of a PCR product from the tobacco ACT gene was performed on the modified microchip as an application example.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An iminodiacetic acid (IDA)-type adsorbent is prepared at the one end of a capillary by covalently bonding IDA to the monolithic rods of macroporous poly(glycidyl methacrylate-co-ethylene dimethacrylate). Cu(II) is later introduced to the support via the interaction with IDA. By this means, polymer monolithic immobilized metal affinity chromatography (IMAC) materials are prepared. With such a column, IMAC for on-line concentration and capillary electrophoresis (CE) for the subsequent analysis are hyphenated for the analysis of peptides and proteins. The reproducibility of such a column has been proved good with relative standard deviations (RSDs) of dead time of less than 5% for injection-to-injection and 12% for column-to-column (n = 3). Through application on the analysis of standard peptides and real protein samples, such a technique has shown promising in proteome study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ginseng is one of the most expensive Chinese herbal medicines and the effectiveness of ginseng depends strongly on its botanical sources and the use of different parts of the plants. In this study, a microchip electrophoresis method coupled with the polymerase chain reaction (PCR)-short tandem repeats (STR) technique was developed for rapid authentication of ginseng species. A low viscosity hydroxypropyl methylcellulose (HPMC) solution was used as the sieving matrix for separation of the amplified STR fragments. The allele sizing of the amplified PCR products could be detected within 240 s or less. Good reproducibility and accuracy of the fragment size were obtained with the relative standard deviation for the allele sizes less than 1.0% (n = 11). At two microsatellite loci (CT 12, CA 33), American ginseng had a different allele pattern on the electropherograms compared with that of the Oriental ginseng. Moreover, cultivated and wild American ginseng can be distinguished on the basis of allele sizing. This work establishes the feasibility of fast genetic authentication of ginseng species by use of microchip electrophoresis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Oxidized carbon nanotubes are tested as a matrix for analysis of small molecules by matrix assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF-MS). Compared with nonoxidized carbon nanotubes, oxidized carbon nanotubes facilitate sample preparation because of their higher solubility in water. The matrix layer of oxidized carbon nanotubes is much more homogeneous and compact than that of nonoxidized carbon nanotubes. The efficiency of desorption/ionization for analytes and the reproducibility of peak intensities within and between sample spots are greatly enhanced on the surface of oxidized carbon nanotubes. The advantage of the oxidized carbon nanotubes in comparison with alpha-cyano-4-hydroxycinnamic acid (CCA) and carbon nanotubes is demonstrated by MALDI-TOF-MS analysis of an amino acid mixture. The matrix is successfully used for analysis of synthetic hydroxypropyl P-cyclodextrin, suggesting a great potential for monitoring reactions and for product quality control. Reliable quantitative analysis of jatrorrhizine and palmatine with a wide linear range (1-100 ng/mL) and good reproducibility of relative peak areas (RSD less than 10 %) is achieved using this matrix. Concentrations of jatrorrhizine (8.65 mg/mL) and palmatine (10.4 mg/mL) in an extract of Coptis chinensis Franch are determined simultaneously using the matrix and a standard addition method. (c) 2005 American Society for Mass Spectrometry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The major components of the plant curcuma longa are the curcuminoids that include curcumin, demethoxycurcumin and bisdemethoxycurcumin. It has been reported the curcuminoids have some important activities. A new CZE method with diode array detection has been developed for the separation and determination of the curcumin, demethoxycurcumin and bisdemethoxycurcumin. Three curcuminoids could be readily separated within 7 min with a 15 mM sodium tetraborate buffer containing 10% methanol (v/v) at pH 10.8, 25 kV and 30 degrees C. The method has been validated and shows good performance with respect to selectivity, reproducibility, linearity, limits of detection and recovery. The proposed method was successfully applied to determine the curcuminoids in urine. (c) 2004 Elsevier B.V. All rights reserved.