120 resultados para BANDWIDTH MEASUREMENTS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An experiment to study exotic two-proton emission from excited levels of the odd-Z nucleus P-28 was performed at the National Laboratory of Heavy Ion Research-Radioactive Ion Beam Line (HIRFL-RIBLL) facility. The projectile P-28 at the energy of 46.5 MeV/u was bombarding a Au-197 target to populate the excited states via Coulomb excitation. Complete-kinematics measurements were realized by the array of silicon strip detectors and the CsI + PIN telescope. Two-proton events were selected and the relativistic-kinematics reconstruction was carried out. The spectrum of relative momentum and opening angle between two protons was deduced from Monte Carlo simulations. Experimental results show that two-proton emission from P-28 excited states less than 17.0 MeV is mainly two-body sequential emission or three-body simultaneous decay in phase space. The present simulations cannot distinguish these two decay modes. No obvious diproton emission was found.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present the first measurements of identified hadron production, azimuthal anisotropy, and pion interferometry from Au + Au collisions below the nominal injection energy at the BNL Relativistic Heavy-Ion Collider (RHIC) facility. The data were collected using the large acceptance solenoidal tracker at RHIC (STAR) detector at root s(NN) = 9.2 GeV from a test run of the collider in the year 2008. Midrapidity results on multiplicity density dN/dy in rapidity y, average transverse momentum < p(T)>, particle ratios, elliptic flow, and Hanbury-Brown-Twiss (HBT) radii are consistent with the corresponding results at similar root s(NN) from fixed-target experiments. Directed flow measurements are presented for both midrapidity and forward-rapidity regions. Furthermore the collision centrality dependence of identified particle dN/dy, < p(T)>, and particle ratios are discussed. These results also demonstrate that the capabilities of the STAR detector, although optimized for root s(NN) = 200 GeV, are suitable for the proposed QCD critical-point search and exploration of the QCD phase diagram at RHIC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports laboratory measurements of the spectrum of the most abundant transition Fe ions in the universe. Spectrum of iron of low-lying excited states has been observed in the wavelength range 250-400 angstrom at Chinese Institute of Atomic Energy on the HI-13 tandem accelerator with beams of 130 MeV. A number of spectral lines have been mainly classified as transitions of magnesium-, sodium-, neon-, fluorine-like ions. A total of 54 lines have been measured. Most of them have been mainly ascribed to 3s3p(k)-3p(k+1), 3s(2)3p(k)-3s3p(k+1), 2p(5)3s-2p(5)3p, 3s3d-3p3d and 2p(5)3p-2p(5)3d resonance transitions. These spectral lines have been identified, among which 21 are new and accurately measured. The analysis of the spectra was based on a comparison with other experimental results and calculated values. (c) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Isochronous Mass Spectrometry is a high accurate mass spectrometer. A secondary electrons time detector has been developed and used for mass measurements. Secondary electrons from a thin carbon foil are accelerated by ail electric field and deflected 180 degrees by a magnetic field onto a micro-channel plate. The time detector has been tested with alpha particles and a time resolution of 197 ps (FWHM) was obtained in the laboratory. A mass resolution around 8 x 10(-6) For Delta m/m was achieved by using this time detector in a pilot mass measurement experiment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A review based on 94 cited original papers describes recent achievements in application of different electrochemical detection in flow analysis, injection techniques of flow analysis, liquid chromatography and capillary electrophoresis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reducing uncertainties in the estimation of land surface evapotranspiration (ET) from remote-sensing data is essential to better understand earth-atmosphere interactions. This paper demonstrates the applicability of temperature-vegetation index triangle (T-s-VI) method in estimating regional ET and evaporative fraction (EF, defined as the ratio of latent heat flux to surface available energy) from MODIS/Terra and MODIS/Aqua products in a semiarid region. We have compared the satellite-based estimates of ET and EF with eddy covariance measurements made over 4 years at two semiarid grassland sites: Audubon Ranch (AR) and Kendall Grassland (KG). The lack of closure in the eddy covariance measured surface energy components is shown to be more serious at MODIS/Aqua overpass time than that at MODIS/Terra overpass time for both AR and KG sites. The T-s-VI-derived EF could reproduce in situ EF reasonably well with BIAS and root-mean-square difference (RMSD) of less than 0.07 and 0.13, respectively. Surface net radiation has been shown to be systematically overestimated by as large as about 60 W/m(2). Satisfactory validation results of the T-s-VI-derived sensible and latent heat fluxes have been obtained with RMSD within 54 W/m(2). The simplicity and yet easy use of the T-s-VI triangle method show a great potential in estimating regional ET with highly acceptable accuracy that is of critical significance in better understanding water and energy budgets on the Earth. Nevertheless, more validation work should be carried out over various climatic regions and under other different land use/land cover conditions in the future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For a sphere electrode enclosed in finite-volume electrolyte, the measured current will deviate from the result predicted by the semi-infinite diffusion theory after some time. By random-walk simulation, we compared this time to the one needed for diffusion layer to reach electrolyte boundary, and revealed a clear signal delay of electrochemical current. Further we presented a quantitative description of this delay time. The simulation results suggested that the semi-infinite diffusion theory can even be applied when the theoretical diffusion layer grows to 1.28 electrolyte thicknesses, with an accuracy better than 0.5%. We attributed this time delay to the molecules' finite propagation velocity. Finally, we discussed how this delay can influence and facilitate the following electrochemical detection towards the nanometer and single-cell scale.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method is developed to estimate the coverage of an electropolymerizable aniline-analogue monolayer (mixture of 2- and 3-aminophenols, 2/3-ATP) by measuring the charge capacitance of the electrode (theta = 81%). The technique of filling the uncovered area (defect sites) of the aniline-analogue monolayer with alkanethiols with long alkane chains (1-decanethiol, 1-DT) has been used to determine the coverage. The dielectric constant (permittivity) of the PANI-analogue monolayer was determined to 8.4. Adsorption kinetics of 1-DT was also studied, and the value of the rate constant of the secondary adsorption was measured to 0.9 mol(-1) dm(3) s(-1).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this communication we analyse current versus voltage data obtained using one carrier injection at metal/polymer/metal structures, The used polymer is a soluble blue-emitting alternating block copolymer, Our experimental results demonstrate that the electron current is limited by a large amount of traps with exponential energy distribution in the copolymer. The electron ;mobility of 5.1 x 10(-10) cm(2)/V s is directly determined by space-charge-limited current measurements. The electron mobility is at least three orders of magnitude smaller than that for holes in the copolymer. (C) 1999 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The interface thickness in two-component interpenetrating polymer networks (IPN) system based on polyacrylate and epoxy were determined using small-angle X-ray scattering (SAXS) in terms of the theory proposed by Ruland. The thickness was found to be nonexistent for the samples at various compositions and synthesized at variable conditions-temperature and initiator concentration. By viewing the system as a two-phase system with a sharp boundary, the roughness of the interface was described by fractal dimension, D, which slightly varies with composition and synthesis condition. Length scales in which surface fractals are proved to be correct exist for each sample and range from 0.02 to 0.4 Angstrom(-1). The interface in the present IPN system was treated as fractal, which reasonably explained the differences between Pored's law and experimental data, and gained an insight into the interaction between different segments on the interface. (C) 1997 Elsevier Science Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eleven new lifetimes of odd parity excited energy levels in four configurations: 4f12 5d 6s 6p, 4f12 6S2 6p, 4f13 5d 6s and 4f13 6s 7s of atomic thulium have been mesured with atomic-beam laser spectrocopy. Two pulsed dye lasers are used for stepwise excitation and the time-resolved fluorescence decay was used to determine lifetime values. The accuracy of the measurements is about 10%.