95 resultados para peak alignment


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This payer presents a concrete theoretical treatment which can be used for transforming the laser-induced fluorescence (LIF) intensity into the population and alignment parameters of a symmetric top molecule, The molecular population and alignment are described by molecular state multipoles. The results are presented in a general excitation-detection geometry and then specialized in some special geometries. The problem how to extract the initial molecular state multipoles from the rotationally resolved LIF intensity is discussed in detail. (C) 1999 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

General expressions used for transforming raw laser-induced fluorescence (LIF) intensity into the population and alignment parameters of a symmetric top molecule are derived by employing the density matrix approach. The molecular population and alignment are described by molecular state multipoles. The results are presented for a general excitation-detection geometry and then applied to some special geometries. In general cases, the LIF intensity is a complex function of the initial molecular state multipoles, the dynamic factors and the excitation-detection geometrical factors. It contains a population and 14 alignment multipoles. How to extract all initial state multipoles from the rotationally unresolved emission LIF intensity is discussed in detail.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

General expressions used for extracting the orientation and alignment parameters of a symmetric top molecule from laser-induced fluorescence (LIF) intensity are derived by employing the density matrix approach. The molecular orientation and alignment are described by molecular state multipoles. Excitation and detection are circularly and linearly polarized lights, respectively. In general cases, the LIF intensity is a complex function of the initial molecular state multipoles, the dynamic factors and the excitation-detection geometrical factors. It contains a population, ten orientation and fourteen alignment multipoles. The problem of how to extract the initial molecular state multipoles from the resolved LIF intensity is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Expressions used for extracting the population and alignment parameters of a symmetric top molecule from (n + 1) laser-induced fluorescence (LIF) are derived by employing the tensor density matrix method. The molecular population and alignment are described by molecular state multipoles. The LIF intensity is a complex function of the initial molecular state multipoles, the dynamic factors, and the excitation-detection geometrical factors. The problem of how to extract the initial molecular state multipoles from (2 + 1) LIF, as an example, is discussed in detail. (C) 2000 American Institute of Physics. [S0021-9606(00)30744-9].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A data manipulation method has been developed for automatic peak recognition and result evaluation in the analysis of organic chlorinated hydrocarbons with dual-column gas chromatography. Based on the retention times of two internal standards, pentachlorotoluene and decachlorobiphenyl, the retention times of chlorinated hydrocarbons can be calibrated automatically and accurately. It is very convenient to identify the peaks by comparing the retention times of samples with the calibrated retention times calculated from the relative retention indices of standards. Meanwhile, with a suggested two-step evaluation method the evaluation coefficients and the suitable quantitative results of each component can be automatically achieved for practical samples in an analytical system using two columns with different polarities and two internal standards. (C) 2002 Elsevier Science B.V. All rights reserved.