112 resultados para Reproducibility


Relevância:

10.00% 10.00%

Publicador:

Resumo:

1:12-Silicomolybdic acid (SiMo12) doped carbon ceramic composite electrodes were fabricated by incorporating SiMo12 and graphite powder in a methyltrimethoxysilane-based gel and characterized by cyclic and square-wave voltammetry, It was demonstrated that the chemically modified electrodes were suitable for electrocatalytic reduction of bromate, The electrodes had the remarkable advantage of surface renewal owing to bulk modification, as web as simple preparation, good mechanical and chemical stability and reproducibility.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A novel glucose biosensor based on cast lipid film was developed. This model of biological membrane was used to supply a biological environment on the surface of the electrode, moreover it could greatly reduce the interference and effectively exclude hydrophilic electroactive material from reaching the detecting surface. TTF was selected as a mediator because of its high electron-transfer efficiency, and it was incorporated in the lipid film firmly. Glucose oxidase was immobilized in hydrogel covered on the lipid film. The effects of pH, operating potential were explored for the optimum analytical performance by using amperometric method. The response time of the biosensor was less than 20 s, and the linear range is up to 10 mmol l(-1) (corr. coeff. 0.9932) with the detection limit of 2 x 10(-5) mol l(-1). The biosensor also exihibited good stability and reproducibility. (C) 2000 Elsevier Science S.A. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new type of silicomolybdate-methylsilicate-graphite composite material was prepared by the sol-gel technique and used for the fabrication of an amperometric nitrite sensor. The silicomolybdic anion acts as a catalyst, the graphite powder ensures conductivity by percolation, the silicate provides a rigid porous backbone and the methyl groups endow hydrophobicity and thus limit the wetting section of the modified electrode. Cyclic voltammetry, square-wave voltammetry and chronoamperometry were employed to characterize the sensor. The amperometric nitrite sensor exhibited a series of good properties: high sensitivity (1.771 mu A mmol(-1) dm(3)), a short response time (7 s), remarkable long-term stability and especially reproducibility of surface renewal in the event of electrode surface fouling.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

9,10-Phenanthrenequinone (PQ) supported on graphite powder by adsorption was dispersed in propyltrimethoxysilane-derived gels to yield a conductive composite which was used as electrode material to fabricate a PQ-modified carbon ceramic electrode. In this configuration, PQ acts as a catalyst, graphite powder guarantees conductivity by percolation, the silicate provides a rigid porous backbone, and the propyl groups endow hydrophobicity and thus limit the wetting region of the modified electrode. Square-wave voltammetry was exploited to investigate the pH-dependent electrochemical behavior of the composite electrode and an almost Nernstian response was obtained from pH 0.42 to 6.84. Because the chemically modified electrode can electrocatalyze the reduction of iodate in acidic aqueous solution (pH 2.45), it was used as an amperometric sensor for the determination of iodate in table salt. The advantages of the electrode are that it can be polished in the event of surface fouling, it is simple to prepare, has excellent chemical and mechanical stability, and the reproducibility of surface-renewal is good.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A novel glucose biosensor based on capacitive detection has been developed using molecularly imprinted polymers. The sensitive layer was prepared by electropolymerization of o-phenylenediamine on a gold electrode in the presence of the template (glucose). Cyclic voltammetry and capacitive measurements monitored the process of electropolymerization. Surface uncovered areas were plugged with 1-dodecanethiol to make the layer dense, and the insulating properties of the layer were studied in the presence of redox couples. The template molecules and the nonbound thiol were removed from the modified electrode surface by washing with distilled water. A capacitance decrease could be obtained after injection of glucose. The electrode constructed similarly but with ascorbic acid or fructose only showed a small response compared with glucose. The stability and reproducibility of the biosensor were also investigated. (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A kind of solid substrate, glassy carbon (GC) electrode. was selected to support self-assembled lipid layer membranes. On the surface of GC electrode. we made layers of dimyristoylphosphatidylcholine (DMPG, a kind of lipid). From electrochemical impedance experiments. we demonstrated that the lipid layers on the GC electrode were bilayer lipid membranes. We immobilized horseradish peroxidase (HRP) into the supported bilayer lipid membranes (s-BLM) to develop a kind of mediator-free biosensor for H2O2. The biosensor exhibited fine electrochemical response, stability and reproducibility due to the presence of the s-BLM. As a model of biological membrane, s-BLM could supply a biological environment for enzyme and maintain its activity. So s-BLM is an ideal choice to immobilize enzyme for constructing the mediator-free biosensor based on GC electrode. (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have made a cheap microsystem of capillary electrophoresis with a new method, integrating the electrodes, injection channel, separation channel, buffer reservoirs and detection cell on a polymethylmethacrylate (PMMA) chip. Using an integrated micro carbon fiber disk electrode as the working electrode in three electrodes system, 1 x 10(-4) mol/L dopamine(DA) could be detected with end-column amperometric detection. The reproducibility was good. Peak current was 6.73 nA,theoretical plate number was 71300/m and height equivalent of one theoretical plate height was 14.0 mum for 1 x 10(-4) mol/L DA. The limit of detection was 3.6 x 10(-8) mol/L and the linear range was extended from 5 x 10(-7) mol/L to 1 x 10(-4) mol/L for DA. 1 x 10(-4) mol/L catechol (CA) and 5 x 10(-5) mol/L DA were also separated completely with R-s = 10.1.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Determination of aesculin (AL) and aesculetin (AT) by capillary electrophoresis with end-column amperometric detection using a 33 mu m microdisk carbon fiber electrode is described. The HDVs, the effect of pH, buffer concentration, injection voltage, injection time and separation voltage on the peak current response (i(p)) of the analytes and the number of theoretical plates (N) were studied. The method has high sensitivity and good reproducibility. Under the optimum condition - 10 mM, pH 9.00 phosphate buffer, 4 s at 9 kV injection, separation at 15 kV and +1.0 V as the detection potential - low detection limits (S/N = 3) of 0.06 and 0.3 mu M were obtained for AL and AT, respectively. The calibration curve was linear over three orders of magnitude. The relative standard deviations (n = 15) of peak current and migration time were 3.9% and 4.6%, and 0.96% and 0.75% for 15 consecutive injections of 5 mu M AL and AT, respectively. The use of this method for the separation and detection of the two compounds present in the traditional Chinese medicine and human urine samples is also reported. (C) 1999 Elsevier Science B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

End-column amperometric detection of 6-mercaptopurine by capillary zone electrophoresis was described with high resolution and speed. The detection conditions were optimized and the electrochemical behavior was observed. Under the optimal conditions: detection potential of 1.2 V ( vs. Ag/AgCl), operating voltage of 15 kV, sample injection of 3 s at 15 kV and 10 mmol/l Na2HPO4 buffer, the detection limit for 6-MP was as low as 1 x 10(-7) mol/L and the linear range was from 5 x 10(-4) to 5 x 10(-6) mol/L with the relative coefficient of 0.995. The RSD of reproducibility for peak current and migration time was 2.5% and 1.2%, respectively. This method was utilized in assay real sample of human mine and bovine serum albumin containing 6-mercaptopurine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A tyrosinase-based amperometric biosensor using a self-gelatinizable graft copolymer of poly(vinyl alcohol) with 4-vinylpyridine (PVA-g-PVP) as an immobilization matrix was constructed. The 4-vinylpyridine component of PVA-g-PVP enhances the adherence to a glassy carbon electrode surface. The content of 4-vinylpyridine in this immobilization matrix plays a key role in retaining the activity of tyrosinase. A simple, milder method was adopted by simply syringing the copolymer-tyrosinase aqueous solution on to the electrode surface and allowing water to evaporate at 4 degrees C in a refrigerator. Several parameters, including copolymer composition; pH, applied potential and enzyme membrane composition, ware optimized. The enzyme membrane composition can be varied to obtain higher sensitivity or a wider linear detection range. The biosensor was used for the determination of phenol, p-cresol and catechol. The biosensor exhibited excellent reproducibility, stability and sensitive response and can be used in flow injection analysis. The biosensor showed an extended linear range in hydrophilic organic solvents and it can be used in monitoring organic reaction processes. The analytical performance demonstrated this immobilization matrix is suitable for the immobilization of tyrosinase.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Molecular weight of 8 ginsenosides and the component of total saponions in American ginseng have been determined by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). The average error of the molecular weight of each ginsenoside was found less than 0.05%. The results demonstrate that MALDI-MS is a very simple and useful method to measure the molecular weight of some high polar, thermal unstable small molecules with high sensitivity and reproducibility.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chromatography-amperometric detection of nitrite with a polypyrrole modified glassy carbon electrode doped with tungstodiphosphate anion (Dawson-type P2W18O626-/PPy/GC electrode) based on its electrocatalytic reduction of nitrite is described. The cyclic and hydrodynamic voltammetry of nitrite at the P2W18O626-/PPy/GC electrode was studied. The factors affecting the detection of nitrite and the analytical performance of the modified electrode in flowing stream were investigated. The results show that the modified electrode has a good sensitivity (the limit of detection is 1 mu mol dm(-3)) and a satisfactory reproducibility (RSD = 3.78%, N = 21). The modified electrode was used in the chromatographic detection of nitrite spiked in the liquid from a tin of mushrooms and the mineralized spring water. It was found that the modified electrode exhibited good selectivity for nitrite.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A highly dispersed ultramicro palladium-particle modified carbon fiber microdisk array electrode (Pd-CFE) was employed for capillary electrophoresis-electrochemical (CEEC) detection of hydroxylamine (HA). The Pd particles obtained were in the nanometer scale, had a high electrocatalytic activity towards HA and exhibited good reproducibility and stability. A linear relationship between the current and the analyte concentration was found between 5 x 10(-6) and 1 x 10(-3) mol/l of HA with a correlation coefficient of 0.9992. The detection limit was 5 x 10(-8) mol/l. The applicability of the method for the determination of HA in river water and waste water was investigated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Supported lipid membranes consisting of self-assembled alkanethiol and lipid monolayers on gold substrates could be produced by three different deposition methods: the Langmuir-Blodgett (L-B) technique, the painted method, and the paint-freeze method, By using cyclic voltammetry, chronoamperometry/chronocoulometry and a.c. impedance measurements, we demonstrated that lipid membranes prepared by these three deposition methods had obvious differences in specific capacitance, resistance and thickness. The specific capacitance of lipid membranes prepared by depositing an L-B monolayer on the alkanethiol alkylated surfaces was 0.53 mu Fcm(-2), 0.44 mu Fcm(-2) by the painted method and 0.68 mu Fcm(-2) by the paint-freeze method. The specific conductivity of lipid membranes prepared by the L-B method was over three times lower than that of the painted lipid membranes, while that of the paint-freeze method was the lowest. The difference among the three types of lipid membranes was ascribed to the influence of the organic solvent in lipid films and the changes in density of the films. The lipid membranes prepared by the usual painted method contained a trace amount of the organic solvent. The organic solvent existing in the hydrocarbon core of the membrane reduced the density of the membrane and increased the thickness of the membrane. The membrane prepared by depositing an L-B monolayer containing no solvent had higher density and the lowest fluidity, and the thickness of the membrane was smaller. The lipid membrane prepared by the paint-freeze method changed its structure sharply at the lower temperature. The organic solvent was frozen out of the membrane while the density of the membrane increased greatly. All these caused the membrane to exist in a ''tilted'' state and the thickness of this membrane was the smallest. The lipid membrane produced by the paint-freeze method was a membrane not containing organic solvent. This method was easier in manipulation and had better reproducibility than that of the usual painting method and the method of forming free-standing lipid film. The solvent-free membrane had a long lifetime and a higher mechanical stability. This model membrane would be useful in many areas of scientific research.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A palladium particle-modified carbon fiber microdisk array electrode was designed and employed in capillary electrophoresis for the simultaneous detection of hydrazine, methylhydrazine, and isoniazid. The Pd-modified microdisk electrode had high catalytic ability for hydrazines and exhibited good reproducibility and stability. The response for hydrazine was linear over 3 orders of magnitude with a correlation coefficient of 0.993. The detection limits far hydrazine, methylhydrazine, and isoniazid were 1.2, 2.1, and 6.2 pg, respectively.