105 resultados para Flow rate variation
Resumo:
环境突发污染事故给人民生活、经济发展和生态环境造成重大影响,研究污染物泄漏造成河流突发污染事故的应急处理方法十分必要。本论文选取苯酚、苯胺和亚甲基蓝等典型污染物为实验对象,采用吸附容量大、密度与水接近的活性炭纤维(ACF)为吸附剂。在自制的河流模型中,研究了ACF以苯酚、苯胺和亚甲基蓝为典型污染物的吸附过程,考察了吸附剂投加量、污染物浓度、吸附剂比表面积、吸附剂投加方式、水流速度与水质等对吸附速率与吸附效果的影响。实验结果表明,ACF能以较快的速率吸附苯酚、苯胺和亚甲基蓝,吸附率都在95%以上; ACF投加量是影响吸附速率最重要的因素,当一次性投加ACF质量之比为 1:2:4时,吸附速率常数之比近似为1:2:4;污染物浓度对吸附速率的影响显著,浓度较低时吸附速率较高。苯酚初始浓度为7mg·L-1时,经过86分钟的吸附,处理后的浓度可以达到地表水Ⅴ类水中挥发酚的限值要求(0.1mg·L-1);在吸附11分钟左右追加适量的ACF,能够明显提高吸附速率;河水流速和河流中的天然有机物、浊度、河水硬度对ACF吸附都不产生显著影响,这说明ACF作为河流突发污染事故应急处理的吸附剂,有广泛的适应性。在实际河水中,ACF对苯酚的吸附过程与在模拟河水中相似,吸附效果显著。实验结果还表明,ACF对苯酚的吸附是放热反应,符合Freundlich模型和Langmuir模型。事故应急处理后,应该及时将吸附了污染物的ACF打捞上来,有利于进行后续处理。 Emergency environmental pollution accidents pose significant impacts on our living, economic development and ecological environment. The study on the approach of emergency control for the contingency caused by leakage of pollutants in rivers is very necessary. In the experiment, phenol, aniline and methylene blue were selected as representative pollutant and activated carbon fiber (ACF) was selected as adsorbent, which has strong adsorption capacity and similar density to water. In the self-made river model, the effects of ACF dosage, pollutant concentration, ACF surface area, ACF adding ways, water flow rate and water quality on adsorption courses were investigated. The experimental results showed that ACF could adsorb pollutant quickly and effectively. The ACF dosage was the most important factor that affected adsorption rate .When the ACF dosage rate was 1:2:4, the constants of adsorption rate was approximately 1:2:4. The effect of pollutant concentrations on the adsorption rate was notable. Faster adsorption rates were achieved at low pollutant concentrations. Phenol concentration reached the limits of volatile phenol in Category Ⅴ surface water (0.1 mg·L-1) after 86 minutes of adsorption with initial phenol concentration of 7 mg·L-1. After 11 minutes of adsorption, certain amount of ACF was added and the adsorption rate was improved significantly. River flow rate and water quality have little effect on the adsorption rate. The adsorption results obtained in actual river water were comparable with that in simulating river water. The results also showed that, ACF on the absorption of phenol is exothermic reaction, witch matched with the Freundlich model and the Langmuir model. After emergency treatment, the ACF absorbed pollutants should be promptly salvaged for follow-up treatment.
Resumo:
A packed-bed electroosmotic pump (EOP) was constructed and evaluated. The EOP consisted of three capillary columns packed in parallel, a gas-releasing device, Pt electrodes and a high-voltage power supply. The EOP could generate output pressure above 5.0 MPa and constant flow rate in the range of nl/min to a few mul/min for pure water, pure methanol, 2 mM potassium dihydrogenphosphate buffer, the buffer-methanol mixture and the pure water-methanol mixture at applied potentials less than 20 W The composition of solvent before/after pumping was quantitatively determined by using a gas chromatograph equipped with both flame ionization detector and thermal conductivity detector. It was found that there were no apparent changes in composition and relative concentrations after pumping process for a methanol-ethanol-acetonitrile mixture and a methanol-water mixture. Theoretical aspect of the EOP was discussed in detail. An capillary HPLC system consisting of the EOP, an injection valve, a 15 cm x 320 mum i.d., 5 mum Spherigel C(18) stainless steel analytical column, and an on-column UV detector was connected to evaluate the performance of the EOP. A comparative study was also carried out with a mechanical capillary HPLC pump on the same system. The results demonstrated that the reproducibility of flow rate and the pulsation-free flow property of the EOP are superior to that of mechanical pump in capillary HPLC application. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
Three molecularly imprinted monolithic columns with different length but almost identical column volume had been prepared. It was observed that the separation factors of diastereomers and enantiomers were almost unaffected by column length. However, the short column with dimension of 38 mm x 8 mm W. showed much lower resistance to flow rate so that it could be operated at much higher flow rates. By combining stepwise gradient elution with elevated flow rate, the diastereomers of cinchonine and cinchonidine and the enantiomers of Cbz-DL-Trp and Fmoc-DL-Trp were successfully separated within 3 min on the short column with dimension of 38 mm. x 8 mm i.d.. Based on the above results, a cinchonine imprinted monolithic disk with dimension of 10 mm x 16 mm W. was further developed. The SEM image and the pore size distribution profile showed that large flow-through pores are present on the prepared monolith, which allowed mobile phase to flow through the disk with very low resistance. Chromatographic performances on the monolithic disk were almost unchanged compared with the long columns. A rapid separation of cinchonine and cinchonidine was achieved in 2.5 min at the flow rate of 9.0 ml/min. Furthermore, it was observed that there was almost no effect of the flow rate on the dynamic binding capacity at high flow rates. In addition, the effect of the loading concentration of analytes on the dynamic binding capacity, namely adsorption isotherm, was also investigated. A non-linear adsorption isotherm of cinchonine was observed on the molecularly imprinted monolith with cinchonine as template, which might be a main reason to result in the peak tailing of template molecule. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
An electroosmotic pump (EOP) capable of generating pressure above 3 MPa and mul/min flow rate with reverse phase mobile phases of HPLC was constructed and evaluated. The pump consisted of three parallel connected fused silica capillary columns (25 cm x 320 mum I.D.) packed with 2 mum silica materials, hollow electrodes, a high voltage DC power supply, and. a liquid pressure transducer. The EOP was applied in a capillary liquid chromatographic system for mobile phase delivery instead of a mechanical pump. Standard samples containing thiourea, naphthalene, anthracene, phenanthrene and acetonitrile were separated on a 15 cm x 320 mum I.D. 5 mum Chromasil C-18 packed capillary column with acetonitrile/water as mobile phase. (C) 2003 Elsevier Science B.V. All rights reserved.
Resumo:
Direct synthesis of alcohols from CO and H2O was investigated using TiO2 catalyst. MeOH (about 24 mg g(-1) h(-1)) and EtOH (about 8 mg g(-1) h(-1)) could be produced under the reaction conditions of T= 573 K, P= 0.5 MPa, CO flow rate of 30 ml min(-1) and CO/H2O = 3/2 during the period of 12 to 44 h time-on-stream. Compared with PbO, TiO2 could preserve stable catalytic activity during a long time of reaction. For the same catalyst TiO2, the reaction performance of alkali carbonates increased with their solubility (K2CO3>Na2CO3>Li2CO3). The corresponding catalytic activity was found to increase with the alkalescence of solvent. The formation mechanism of alcohols was proposed as well. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
The reaction performance for CO hydration on a TiO2 catalyst under different calcination temperatures was investigated. Under reaction conditions of T = 573 K, P = 0.5 MPa, CO flow rate of 30 ml min(-1), TOS = 12 h, and CO/H2O (g) = 3/2 (mol), the TiO2 catalyst with a futile content of 18% shows a maximum alcohols STY of 1.81 Mg m(-2) h(-1). In addition, the catalyst deactivation and regeneration were discussed.
Resumo:
The environmentally friendly removal of NO has been investigated using continuous microwave discharge (CMD) at atmospheric pressure. In these experiments, conversions of NO to N-2 as well as NO2 were mainly observed for both dry and wet feed gas, which showed a great difference from those observed with other discharge methods. The effects of a series of reaction parameters, including microwave input power, O-2 concentration, NO concentration, and gas flow rate, on the product distribution and energy efficiency were also studied. Under all reaction conditions, the conversions of NO to N-2 were higher than those to NO2. The highest conversion of NO to N-2 was 88%. The reaction rate of NO removal and the effects of the different discharge modes on NO conversion and product distribution are also discussed. Through comparison of the results of different discharge modes, it was found that the addition of CH4 apparently increased the conversion of NO to N-2 as well as the energy efficiency. A possible reaction process is suggested.
Resumo:
The suitability of membrane cartridges for the removal of endotoxin from both distilled water and interferon preparations was examined. The endotoxin concentrations were reduced to 4.0 and 7.3 EU/ml, respectively, when about 4000 ml of distilled water with 20 and 28 EU/ml were passed through the deoxycholate and chitosan immobilized membrane cartridges. When 200 ml of interferon preparation with endotoxin concentration more than 80 EU/ml and pH 3.9 were applied to a deoxycholate immobilized membrane cartridge at a flow-rate of 9 ml/min, the endotoxin concentration was reduced to less than 10 EU/ml. However, if an interferon preparation of 450 ml, with more than 80 EU/ml of endotoxin and pH 3.9 was applied to the chitosan immobilized membrane cartridge at a flow-rate of 18 ml/min, the endotoxin concentration was reduced to less than 10 EU/ml. (C) 2003 Elsevier Science B.V. All rights reserved.
Resumo:
A 2-kW-class chemical oxygen-iodine laser (COIL) using nitrogen buffer gas has been developed and tested since industrial applications of COIL devices will require the use of nitrogen as the buffer gas. The laser, with a gain length of 11.7 cm, is energized by a square pipe-array jet-type singlet oxygen generator (SPJSOG) and employs a nozzle bank with a designed Mach number of 2.5. The SPJSOG has advantages over the traditional plate-type JSOG in that it has less requirements on basic hydrogen peroxide (BHP) pump, and more important, it has much better operational stability. The SPJSOG without a cold trap and a gas-liquid separator could provide reliable operations for a total gas flow rate up to 450 mmol/s and with a low liquid driving pressure of around 0.7 atm or even lower. The nozzle bank was specially designed for a COIL using nitrogen as the buffer gas. The cavity was designed for a Mach number of 2.5, in order to provide a gas speed and static temperature in the cavity similar to that for a traditional COIL with helium buffer gas and a Mach 2 nozzle. An output power of 2.6 kW was obtained for a chlorine flow rate of 140 mmol/s, corresponding to a chemical efficiency of 20.4%. When the chlorine flow rate was reduced to 115 mmol/s, a higher chemical efficiency of 22.7% was attained. Measurements showed that the SPJSOG during normal operation could provide a singlet oxygen yield Y greater than or equal to 55%, a chlorine utilization U greater than or equal to 85%, and a relative water vapor concentration w = [H2O]/([O-2] + [Cl-2]) less than or equal to 0.1.
Resumo:
A pressurized electrochromatography (pCEC) instrument with gradient capability was used in this work for separation of peptides. Three separation modes, namely, pCEC, high-performance liquid chromatography and capillary electrophoresis can be carried out with the instrument. In pCEC mode, the mobile phase is driven by both electroosmotic flow and pressurized flow, facilitating fine-tuning in selectivity of neutral and charged species. A continuous gradient elution can be carried out conveniently on this instrument, which demonstrates that it is more powerful than isocratic pCEC for separation of complicated samples. The effects of applied voltage, supplementary pressure and ion-pairing agents on separation of peptides in gradient pCEC were investigated. The effects of flow-rate of the pump and the volume of the mixer on resolution were also evaluated. (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
In the presence of K2CO3, TiO2 shows good catalytic activity and stability for the alcohols synthesis from CO and H2O. CO conversion of 7.6% and the STY of MeOH (about 24 mg g(-1) h(-1)) and EtOH (about 8 mg g(-1) h(-1)) are obtained under reaction conditions of T = 573 K, P = 0.5 MPa, CO flow rate of 30 ml min(-1) and CO/H2O = 3/2 during the period of 12 h to 44 h time-on-stream.
Resumo:
Catalytic decomposition of NO was studied over Fe/NaZSM-5 catalyst. Novel results were observed with the microwave heating mode. The conversion of NO to N-2 increased remarkably with the increasing of Fe loading. The effects of a series of reaction parameters, including reaction temperature, O-2 concentration, NO concentration, gas flow rate and H2O addition, on the productivity of N-2 have been investigated. It is shown that the catalyst exhibited good endurance to excess O-2 in the microwave heating mode. Under all reaction conditions, NO converted predominantly to N-2. The highest conversion of NO to N-2 was up to 70%. (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
Monolithic capillary columns for affinity chromatography were prepared by an in situ polymerization procedure using glycidyl methacrylate (GMA) as a monomer and trimethylolpropane trimethacrylate (TRIM) and ethylene dimethacrylate (EDMA) as cross-linkers, respectively. Scanning electron microscopy was applied to characterize the morphology of the end of monolithic capillary and mercury intrusion porosimetry to characterize the polymer rod prepared within the confines of a stainless steel column with 50 mm x 4.6 mm i.d. under the same polymerization condition. Obvious differences in the porous properties between the TRIM- and EDMA-based monoliths could be observed. Moreover, the mechanical stability of these two monolithic capillary columns was compared by testing the reproducibility of the column performance. The rod prepared with GMA and TRIM proved to be mechanically more stable than that prepared with GMA and EDMA. Protein A was immobilized on the monolithic rod for affinity chromatography and the experiments were performed on a capillary electrophoresis instrument, using its pressure system as the driving force. Non-specific adsorption was not observed on the TRIM-based affinity column, as proved with bovine serum albumin (BSA) as a test protein. The affinity column prepared with GMA and TRIM was then applied to determine the hIgG concentration in human serum. The correlative coefficient of the calibration curve reached 0.9942. The amount of adsorbed hIgG was unaffected by the flow rate of the loading buffer, which makes this method suitable for fast determination of biomacromolecules in microliter samples. (C) 2002 Elsevier Science B.V All rights reserved.
Resumo:
该文介绍一种解析方法 ,由细沟剥蚀率与含沙量关系以及剥蚀率与水流含沙量及沟长的微分物理表达式 ,推求出了含沙量与沟长关系数学表达式。提出了一种侵蚀细沟含沙量量化计算的新方法。并将用该方法计算得到的两种流量下细沟水流含沙量结果与由试验值进行了比较 ,结果表明 :两者相关密切 ,得到的 R2值均很高 ,最低为0 .81,验证了此解析式的有效性。验证了细沟土壤侵蚀的剥蚀率与水流含沙量的关系式的正确性