124 resultados para Dose accumulation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

对氦(He)离子高温(600K)注入6H-SiC中的辐照缺陷,在阶梯温度退火后演化行为的拉曼光谱和室温光致发光谱的特征进行了分析.这两种方法的实验结果表明,离子注入所产生晶格损伤的程度与注入剂量有关;高温退火导致损伤的恢复,不同注入剂量造成的晶格损伤需要不同的退火温度才可恢复.在阶梯温度退火下呈现出了点缺陷的复合、氦-空位团的产生、氦泡的形核、长大等特性.研究表明:高温(600K)注入在一定剂量范围内是避免注入层非晶化的一个重要方法,为后续利用氦离子注入空腔掩埋层吸杂或者制备低成本、低缺陷密度的绝缘层上碳化硅(SiCOI)材料提供了可能.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective The purpose of this study is to investigate the effect of subdinical-dose C-12(6+)-beam irradiation on cell cycle and cell apoptosis in hepatocarcinoma cells. Materials and methods The HepG(2) cells were exposed to 0-2.0 Gy of either the C-12(6+) beam or a gamma-ray. Cell survival was detected by clonogenic assay. Cell cycle was determined by flow-cytometry analysis. The apoptosis was monitored by fluorescence microscope with DAPI staining. p53 and p21 expression were detected by Western blot. Results The G(0)/G(1) cells in the irradiated groups were significantly more than those in the control (P<0.05). The C-12(6+)-ion irradiation had a greater effect on the cell cycle of HepG(2) cells (including promoting G(1)-phase and G(2)-phase arrest) than gamma-ray irradiation. The apoptotic cells induced by C-12(6+) beam were significantly more numerous than those induced by gamma-ray (P<0.05). The carbon ions had a stronger effect on p53 and p21 expression than the gamma-ray irradiation. The survival fractions for cells irradiated by C-12(6+) beam were significantly smaller than those irradiated by gamma-ray (P<0.05).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Irradiation has been widely reported to damage organisms by attacking on proteins, nucleic acid and lipids in cells. However, radiation hormesis after low-dose irradiation has become the focus of research in radiobiology in recent years. To investigate the effects of pre-exposure of mouse brain with low-dose C-12(6+) ion or Co-60 gamma (gamma)-ray on male reproductive endocrine capacity induced by subsequent high-dose irradiation, the brains of the B6C3F(1) hybrid strain male mice were irradiated with 0.05 Gy of C-12(6+) ion or Co-60 gamma-ray as the pre-exposure dose, and were then irradiated with 2 Gy as challenging irradiation dose at 4 h after pre-exposure. Serum pituitary gonadotropin hormones, follicle-stimulating hormone (FSH) and luteinizing hormone (LH), testosterone, testis weight, sperm count and shape were measured on the 35th day after irradiation. The results showed that there was a significant reduction in the levels of serum FSH, LH, testosterone, testis weight and sperm count, and a significant increase in sperm abnormalities by irradiation of the mouse brain with 2 Gy of C-12(6+) ion or Co-60 gamma-ray. Moreover, the effects were more obvious in the group irradiated by C-12(6+) ion than in that irradiated by Co-60 gamma-ray. Pre-exposure with low-dose C-12(6+) ion or Co-60 gamma-ray significantly alleviated the harmful effects induced by a subsequent high-dose irradiation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, an investigation on the micro-structure of an Fe-base oxide-dispersion-strengthened (ODS) alloy irradiated with high-energy Ne-20 ions to different doses at a temperature around 0.5T(m) (T-m is the melting point of the alloy) is presented. Investigation with the transmission electron microscopy found that the accelerated growth of voids at grain-boundaries, which is usually a concern in conventional Fe-base alloys under conditions of inert-gas implantation, was not observed in the ODS alloy irradiated even to the highest dose (12000 at.ppm Ne). The reason is ascribed to the enhanced recombination of point defects and strong trapping of Ne atoms at the interfaces of the nano-scale oxide particles in grains. The study showed that ODS alloys have good resistance to the high-temperature inter-granular embrittlement due to inert-gas accumulation, exhibiting prominence of application in harsh situations of considerable helium production at elevated temperatures like in a fusion reactor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To investigate the effects of pre-exposure of mouse testis to low-dose C-12(6+) ions on cytogenetics of spermatogonia and spermatocytes induced by subsequent high-dose irradiation. the testes of outbred Kun-Ming strain mice were irradiated with 0.05 Gy of C-12(6+) ions as the pre-exposure dose, and then irradiated with 2 Gy as challenging dose at 4 h after per-exposure. Poly(ADP-ribose) polymerase (PARPs) activity and PARP-1 protein expression were respectively measured by using the enzymatic and Western blot assays at 4 h after irradiation; chromosomal aberrations in spermatogonia and spermatocytes were analyzed by the air-drying method at 8 h after irradiation. The results showed that there was a significant increase in the frequency of chromosomal aberrations and significant reductions of PARP activity and PARP-1 expression level in the mouse testes irradiated with 2 Gy of C-12(6+) ions. However, pre-exposure of mouse testes to a low dose of C-12(6+) ions significantly increased PARPs activity and PARP-1 expression and alleviated the harmful effects induced by a subsequent high-dose irradiation. PARP activity inhibitor 3-aminobenzamide (3-AB) treatment blocked the effects of PARP-1 on cytogenetic adaptive response induced by low-dose C-12(6+) ion irradiation. The data suggest that pre-exposure of testes to a low dose of heavy ions can induce cytogenetic adaptive response to subsequent high-dose irradiation. The increase of PARP-1 protein induced by the low-dose ionizing irradiation may be involved in the mechanism of these observations. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Treatment planning of heavy-ion radiotherapy involves predictive calculation of not only the physical dose but also the biological dose in a patient body. The goal in designing beam-modulating devices for heavy ion therapy is to achieve uniform biological effects across the spread-out Bragg peak (SOBP). To achieve this, a mathematical model of Bragg peak movement is presented. The parameters of this model have been resolved with Monte Carlo method. And a rotating wheel filter is designed basing on the velocity of the Bragg peak movement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The charge stripping injection method has been adopted for the accumulation of light heavy ions in HIRFL-CSR. This method has some special requirements for the accelerating particles, and at the same time the structure of the injection orbit has to be changed. In this paper, the design of the orbit has been presented, as well as the calculation of the beam line matching. According to the result of commissioning, stripping injection can accumulate the beam to a higher current.