341 resultados para radioactive ions


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surface damage of gallium nitride films irradiated by Arq+ (6 ≤ q ≤ 16) ions at room temperature is studied by the atomic force microscopy. It is found that when charge state exceeds a threshold value, significant swelling was turned into obvious erosion in the irradiated region. The surface change of the irradiated region strongly depends on the charge state and ion fluence. On the other hand, surface change is less dependent on the kinetic energy nearly in the present experimental range (120 keV≤ Ek ≤ 220 keV). For q ≤ 14, surface of the irradiated region iscovered with an amorphous layer, rough and bulgy. A step-up appears between the irradiated and un-irradiated region. Moreover, the step height and the surface roughness are functions of the ion dose and charge state...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Irradiation efect in three carbon allotropes C60, diamond and highly oriented pyrolytic graphite (HOPG) induced by 170 keV B ions, mainly including the process of the damage creation, is investigated by means of Raman spectroscopy technique. The diferences on irradiation sensitivity and structural stability for C60, HOPG and diamond are compared. The analysis results indicate that C60 is the most sensitive for B ions irradiation,diamond is the second one and the structure of HOPG is the most stable under B ion irradiation. The damage cross sections ? of C60, diamond and HOPG deduced from the Raman spectra are 7.78×10−15 , 6.38×10−15 and1.31 × 10−15cm2, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Angular distribution and current dependence of the transmitted ion fraction are investigated for 40 keV Xe7+ bombarding on polycarbonate (PC) nanocapillaries. By measuring the angular distribution of the transmitted ion fraction, a strong guiding efect is found in PC nanocapillaries. Furthermore, with increase of the incident current, a turning point of the transmitted ion fraction is found, which is explained qualitatively by the discharge capacity of the nanocapillaries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Up to now, clinical trials of heavy-ion radiotherapy for superficially placed tumors have been carried out for six times and over 60 selected patients have been treated with 80—100 MeV/u carbon ions supplied by the Heavy Ion Research Facility in Lanzhou (HIRFL) at the Institute of Modern Physics, Chinese Academy of Sciences since November, 2006. A passive irradiation system and a dose optimization method for radiotherapy with carbon-ion beams have been developed. Experimental verification of longitudinally ...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract A state-of-the-art high energy heavy ion microbeam irradiation system is constructed at the Institute of Modern Physics of the Chinese Academy of Sciences. This microbeam system operates in both full current intensity mode and single ion mode. It delivers a predefined number of ions to preselected targets for research in biology and material science. The characteristic of this microbeam system is high energy and vertical irradiation. A quadrupole focusing system, in combination with a series of slits, has been designed to optimize the spatial resolution. A symmetrically achromatic system leads the beam downwards and serves simultaneously as an energy analyzer. A high gradient quadrupole triplet finally focuses a C6+ ion beam to 1 µm in the vacuum chamber within the energy range from 10 MeV/u to 100 MeV/u. In this paper, the IMP microbeam system is described in detail. A systematic investigation of the ion beam optics of this microbeam system is presented together with the associated aberrations. Comparison is made between the IMP microbeam system and the other existing systems to further discuss the performance of this microbeam. Then the optimized initial beam parameters are given for high resolution and high hitting efficiency. At last, the experiment platform is briefly introduced.