156 resultados para carbon-ion beams


Relevância:

90.00% 90.00%

Publicador:

Resumo:

There has been increasing demand to provide higher beam intensity and high enough beam energy for heavy ion accelerator and some other applications, which has driven electron cyclotron resonance (ECR) ion source to produce higher charge state ions with higher beam intensity. One of development trends for highly charged ECR ion source is to build new generation ECR sources by utilization of superconducting magnet technology. SECRAL (superconducting ECR ion source with advanced design in Lanzhou) was successfully built to produce intense beams of highly charged ion for Heavy Ion Research Facility in Lanzhou (HIRFL). The ion source has been optimized to be operated at 28 GHz for its maximum performance. The superconducting magnet confinement configuration of the ion source consists of three axial solenoid coils and six sextupole coils with a cold iron structure as field booster and clamping. An innovative design of SECRAL is that the three axial solenoid coils are located inside of the sextupole bore in order to reduce the interaction forces between the sextupole coils and the solenoid coils. For 28 GHz operation, the magnet assembly can produce peak mirror fields on axis of 3.6 T at injection, 2.2 T at extraction, and a radial sextupole field of 2.0 T at plasma chamber wall. During the commissioning phase at 18 GHz with a stainless steel chamber, tests with various gases and some metals have been conducted with microwave power less than 3.5 kW by two 18 GHz rf generators. It demonstrates the performance is very promising. Some record ion beam intensities have been produced, for instance, 810 e mu A of O7+, 505 e mu A of Xe20+ 306 e mu A of Xe27+, and so on. The effect of the magnetic field configuration on the ion source performance has been studied experimentally. SECRAL has been put into operation to provide highly charged ion beams for HIRFL facility since May 2007.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In order to investigate the biological effects of heavy ion radiation at low closes and the different radiosensitivities of growing and non-growing plants. rice at different lift stages (dry seed, wet seed and seedling) were exposed to carbon ions at closes of 0 02, 0.2, 2 and 20 Gy. Radiobiological effects on survival, root growth and mitotic activity, as well as the induction of chromosome aberrations in root meristem. were observed The results show that radiation exposure induces a stimulatory response at lower close and an inhibitory response at higher dose on the mitotic activity of wet seeds and seedlings Cytogenetic damages are induced in both seeds and seedlings by carbon ion radiation at doses as low as 0.02 Gy Compared with seedlings. seeds are more resistant to the lethal damage and the growth rate damage by high doses of carbon ions, but are more sensitive to cytogenetic damage by low closes of irradiation Different types of radiation induced chromosome aberrations are observed between seeds and seedlings. Based on these results, the relationships between low close heavy ion-induced biological effects and the biological materials are discussed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In the present study, we investigated the mechanisms of apoptosis resistance and the roles of the phosphorylation of BRCA1, p21, the Bax/Bcl-2 protein ratio and cell cycle arrest in IR-induced apoptosis in MCF-7 cells. X-irradiation, in particular at low dose (1 Gy), but not carbon ion irradiation, had a significant antiproliferative effect on the growth of MCF-7 cells. 1 Gy X-irradiation resulted in G1 and G2 phase arrest, but 4 Gy induced a significant G1 block. In contrast, carbon ion irradiation resulted in a significant accumulation in the G2 phase. Concomitant with the phosphorylation of H2AX induced by DNA damage,carbon ion irradiation resulted in an approximately 1.9–2.8-fold increase in the phosphorylation of BRCA1 on serine residue 1524, significantly greater than that detected for X-irradiation. Carbon ion irradiation caused a dramatic increase in p21 expression and drastic decrease in Bax expression compared with X-irradiation. The data implicated that phosphorylation of BRCA1 on serine residue 1524 might,at least partially, induce p21 expression but repress Bax expression. Together, our results suggested that the phosphorylation of BRCA1 at Ser-1524 might contribute to the G2 phase arrest and might be an upstream signal involved in preventing apoptosis signal via upregulation of p21 and downregulation of the Bax/Bcl-2 ratio.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

HIRFL-CSR, a new heavy ion cooler-storage-ring system at IMP, had been in commissioning since the beginning of 2006. In the two years of 2006 and 2007 the CSR commissioning was finished, including the stripping injection (STI), electron-cooling with hollow electron beam, C-beam stacking with the combination of STI and e-cooling, the wide energy-range synchrotron ramping from 7 MeV/u to 1000 MeV/u by changing the RF harmonic-number at mid-energy, the multiple multi-turn injection (MMI), the beam accumulation with MMI and e-cooling for heavy-ion beams of Ar, Kr and Xe, the fast extraction from CSRm and single-turn injection to CSRe, beam stacking in CSRe and the RIBs mass-spectrometer test with the isochronous mode in CSRe by using the time-of-flight method.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A new generation electron cooler has started operation in the heavy ion synchrotron CSRm which is used to increase the intensity of heavy ions. Transverse cooling of the ion beam after horizontal multi-turn injection allows beam accumulation at the injection energy. After optimization of the accumulation process an intensity increase in a synchrotron pulse by more than one order of magnitude has been achieved. In given accumulation time interval of 10 seconds, 108particles have been accumulated and accelerated to the final energy. The momentum spread after accumulation and acceleration in the 10−4 range has been demonstrated in six species of ion beams. Primary measurements of accumulation process varying with electron energy,electron beam current, electron beam profile, expansion factor and injection interval have been performed.The lifetimes of ion beams in the presence of electron beams were roughly measured with the help of DCCT signal.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In commissioning the HIRFL-CSR (Cooler Storage Ring of Heavy Ion Research Facility in Lanzhou),with the spectrum analyzer monitoring the beams on-line, we measured many parameters of the beam status for improving quality of the heavy ion beams. In this paper, the sudden change of the beam center frequency is analyzed.A theoretical analysis is done mainly on instabilities of the electron voltage and the neutralization factor. Simulations were made for the problem. According to the simulation result, we can conclude that it is the instability of neutralization factor that caused the problem. 中文摘要:HIRFL-CSR调试过程中,利用频谱分析仪实时监测束流,根据其上测的数据进行相关参数调整,改善束流的品质。本文对分析仪上观测到的现象一束流的中心频率发生突变进行了研究,主要就电子束的高压不稳定性和中性化因子的突变做了理论分析,并进行了相关的模拟计算 ,根据模拟结果初步断定该现象的出现由电子束的中性化因子导致。

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Electron Cyclotron Resonance (ECR) ion source is regarded as the most efficient machine to produce stable multiple charge state ion beams. Because of the special characteristics, all-permanent magnet ECR ion sources have been widely adopted around the world to produce stable ion beams of multiple charge state with good repetition have been widely adopted around the world to produce stable ion beams of multiple charge state with good repetition and high duty factor for compact research platforms and ion beam implanters. In this paper, all-permanent magnet ECR ion sources developed at IMP are presented, and typical parameters and performances are discussed. The high charge state source, LAPECR2, is mainly used to produce intense high charge state ion beams, and the LAPECR1 source is designed to produce intense ion beams of medium and low charge state. An improved LAPECR1-M is specially designed to produce heavy metal ion beams of low charge state. These ECR ion sources have been adopted by different experimental terminals at IMP and, with their nice performance, many experimental studies could be possible. 中文文摘:ECR(电子回旋共振)离子源是产生稳定的强流多电荷态离子束流最有效装置。全永磁ECR 离子源因其独特的特点为很多中小型多电荷态离子束流实验平台与离子注入机等系统所采用,为后者产生重复性好、稳定性强的多电荷态离子束流。本文着重论述了中国科学院近代物理研究所研制的几台全永磁多电荷态ECR 离子源及其特性与典型性能,如能产生强流高电荷态离子束流的高性能全永磁离子源LAPECR2,能产生强流中 低电荷态离子束流的LAPECR1,能产生多电荷态重金属离子束流的LAPECR1-M 等。这些性能稳定的离子源为提高近代物理研究所相关试验平台的性能提供了关键的束流品质保障。

Relevância:

80.00% 80.00%

Publicador:

Resumo:

To investigate the hot electrons in highly charged electron cyclotron resonance (ECR) plasma, Bremsstrahlung radiations were measured on two ECR ion sources at the Institute of Modern Physics. Used as a comparative index of the mean energy of the hot electrons, a spectral temperature, Tspe, is derived through a linear fitting of the spectra in a semi-logarithmic representation. The influences of the external source parameters, especially the magnetic configuration, on the hot electrons are studied systematically. This study has experimentally demonstrated the importance of high microwave frequency and high magnetic field in the electron resonance heating to produce a high density of hot electrons, which is consistent with the empirical ECR scaling laws. The experimental results have again shown that a good compromise is needed between the ion extraction and the plasma confinement for an efficient production of highly charged ion beams. In addition, this investigation has shown that the correlation between the mean energy of the hot electrons and the magnetic field gradient at the ECR is well in agreement with the theoretical models.中文摘要:ECR(电子回旋共振)离子源是产生稳定的强流多电荷态离子束流最有效装置。全永磁 ECR 离子源因其独特的特点为很多中小型多电荷态离子束流实验平台与离子注入机等系统所采用,为后者产生重复性好、稳定性强的多电荷态离子束流。本文着重论述了中国科学院近代物理研究所研制的几台全永磁多电荷态ECR离子源及其特性与典型性能,如能产生强流高电荷态离子束流的高性能全永磁离子源LAPECR2,能产生强流中低电荷态离子束流的LAPECR1,能产生多电荷态重金属离子束流的LAPECR1-M等。这些性能稳定的离子源为提高近代物理研究所相关试验平台的性能提供了关键的束流品质保障。

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In order to investigate the effect of carbon ion irradiation on apoptosis and Bax/Bcl-2 expression inhuman tongue carcinoma cells, exponentially growing human tongue carcinoma cells (Tb) cultured in vitro were irradiated with 0, 0.5, 1.0, 2.0 or 4.0 Gy of 12C6+ ions respectively. Survival rate of irradiated cells at various doses were measured by MTT assay. The nucleus changes of apoptosis and necrosis of cells stained by Hochest/PI were observed through fluorescence microscope. The cell cycle changes were detected by flow cytometry (FCM). The expressions of Bax and Bcl-2 were detected by Western blot analysis. The results show that the viability of Tb cells decreases gradually with increment of irradiation doses of carbon ions. The proportions of apoptosis cells in the irradiated groups are significantly higher than those in the control group. There is a positive correlation between irradiation doses and retardation strength in G2 /M phase at 24 h after irradiation (P<0.05). And the expressions of Bax and bcl-2 are significantly up-regulated and down-regulated respectively by 12C6+ ion irradiation. It can be concluded from above that cell apoptosis induced by heavy ion with high-LET may be mediated through the Bax/Bcl-2 expression pathway. 探讨重离子辐照对人舌鳞癌Tb细胞的凋亡及Bax/Bcl-2蛋白表达的影响。采用0、0.5、1.0、2.0、4.0 Gy重离子束辐照人舌鳞癌 Tb 细胞,应用 MTT 法检测细胞存活,流式细胞技术检测细胞周期变化,Hoechst33258/PI 复染法观察 Tb 细胞凋亡形态,并采用 Western-blot 法检测 Bax/Bcl-2 蛋白表达情况。结果发现,Tb细胞经12C6+离子束辐照后存活率显著下降,呈剂量依赖性的生长抑制;Tb细胞呈现蓝色荧光浓集成团的凋亡形态,且凋亡比例随辐照剂量增加;G2/M 期细胞百分数随照射剂量增加而增加(P<0.05) 。Western-blot结果显示 Bax 蛋白表达水平随辐照剂量逐渐上升,但在 4 Gy 组其表达不再增高,Bcl-2 蛋白在 1.0、2.0、4.0 Gy组随剂量增大呈下降趋势。以上结果提示重离子束辐照对 Tb 细胞有抑制作用,Bax/Bcl-2 蛋白表达是重离子治癌的机制之一。

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We report some recent progress in constraining the symmetry energy E-sym(rho) at high densities using high-energy heavy-ion collisions. Circumstantial evidence of a soft E-sym(rho) at supra-saturation density is obtained by comparing the pion ratio pi(-)/pi(+) measured recently with FOPI at GSI and the IBUU04 model calculations. Detailed studies indicate that the power of determining the E-sym(rho)from pi(-)/pi(+) is enhanced with decreasing the beam energy to near the pion production threshold, showing a correlation to the increasing nuclear stopping. Among several heavy-ion reaction facilities in the world, the cooling storage ring (HIRFL-CSR), newly commissioned at Lanzhou, delivering heavy-ion beams up to 1 A GeV, to be coupled with advanced detectors will contribute significantly to further studies of the equation of state of asymmetric nuclear matter.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

To meet the requirements of providing high-intensity heavy ion beams the direct plasma injection scheme (DPIS) was proposed by a RIKEN-CNS-TIT collaboration. In this scheme a radio frequency quadrupole (RFQ) was joined directly with the laser ion source (LIS) without a low-energy beam transport (LEBT) line. To find the best design of the RFQ that will have short length, high transmission efficiency and small emittance growth, beam dynamics designs with equipartitioning design strategy and with matched-only design strategy have been performed, and a comparison of their results has also been done. Impacts of the input beam parameters on transmission efficiency are presented, too. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A Superconducting ECR ion source with Advanced design in Lanzhou (SECRAL) was successfully built to produce intense beams of highly charged ions for Heavy Ion Research Facility in Lanzhou (HIRFL). The ion source has been optimized to be operated at 28GHz for its maximum performance. The superconducting magnet confinement configuration of the ion source consists of three axial solenoid coils and six sextupole coils with a cold iron structure as field booster and clamping. For 28GHz operation, the magnet assembly can produce peak mirror fields on axis 3.6T at injection, 2.2T at extraction and a radial sextupole field of 2.0T at plasma chamber wall. A unique feature of SECRAL is that the three axial solenoid coils are located inside of the sextupole bore in order to reduce the interaction forces between the sextupole coils and the solenoid coils. During the ongoing commissioning phase at 18GHz with a stainless steel chamber, tests with various gases and some metals have been conducted with microwave power less than 3.2kW and it turned out the performance is very promising. Some record ion beam intensities have been produced, for instance, 810e mu A of O7+, 505e mu A of Xe20+, 306e mu A of Xe27+, 21e mu A of Xe34+, 2.4e mu A of Xe38+ and so on. To reach better results for highly charged ion beams, further modifications such as an aluminium chamber with better cooling, higher microwave power and a movable extraction system will be done, and also emittance measurements are being prepared.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The high charge state all permanent Electron Cyclotron Resonance Ion Source (ECRIS) LAPECR2 (Lanzhou All Permanent magnet ECR ion source No.2) has been successfully put on the 320kV HV platform at IMP and also has been connected with the successive LEBT system. This source is the largest and heaviest all permanent magnet ECRIS in the world. The maximum mirror field is 1.28T (without iron plug) and the effective plasma chamber volume is as large as circle divide 67mm x 255mm. It was designed to be operated at 14.5GHz and aimed to produce medium charge state and high charge state gaseous and also metallic ion beams. The source has already successfully delivered some intense gaseous ion beams to successive experimental terminals. This paper will give a brief overview of the basic features of this permanent magnet ECRIS. Then commissioning results of this source on the platform, the design of the extraction system together with the successive LEBT system will be presented.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The cooling storage ring, to be built at Lanzhou, will be able to deliver heavy ion beams up to uranium up to 0.52 GeV/u. It is expected to make considerable contribution to nuclear EOS study in the high net baryon-density region. With a relativistic transport model, we performed simulations for U+U collisions with different orientations. It is shown that by combining the forward neutron multiplicity and an event-wise elliptic flow selection, it is possible to identify the tip - tip and body - body head-on collisions. The effective identification of these two extreme configurations will allow us to study the EOS at the highest baryon density in the U+U collisions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

CSR, a new accelerator project under the construction. to upgrade the existing heavy ion cyclotron system in Lanzhou, is a double cooling-storage-ring system. It consists of a main ring and an experimental ring. The heavy ion beams from the cyclotron system will be accumulated and accelerated first in the main ring, then extracted to produce radioactive ion beams or high-Z beams, and finally to be send to the second ring for internal-target experiments.