105 resultados para TRACE AMOUNT
Resumo:
利用中子活化示踪法研究坡面土壤的侵蚀过程 ,发现坡面的相对侵蚀量从坡脚到坡顶随坡长的变化符合 Weibull分布 ,其形状参数主要受降雨量、降雨历时和径流深度的影响 ,尺度参数主要与平均雨强、I3 0 相关。坡面在侵蚀的同时也发生沉积 ,一般来说短历时高强度的降雨沉积量较小 ,而长历时低强度的降雨沉积量较大 ,某一部位侵蚀产沙的沉积量与其距离之间有 y=axb的关系。坡面径流直接影响着坡面的输移比 ,当径流深和径流系数较高时 ,输移比接近于 1,否则输移比降低
Resumo:
A new kind of bismuth film modified electrode to sensitively detect trace metal ions based on incorporating highly conductive ionic liquids 1-butyl-3-methyl-imidazolium hexafluorophosphate (BMIMPF6) in solid matrices at glassy carbon (GC) was investigated. Poly(sodium 4-styrenesulfonate) (PSS), silica, and Nafion were selected as the solid matrices. The electrochemical properties of the mixed films modified GC were evaluated. The electron transfer rate of Fe(CN)(6)(4-)/Fe(CN)(6)(3-) can be effectively improved at the PSS-BMIMPF6 modified GC.
Resumo:
The effect of combination between a trace of halogenated compounds (such as ferric chloride and ammonium bromide) and Ni2O3 particles on the carbonization of polypropylene (PP) was investigated during combustion. The results showed a synergistic catalysis of combined halogenated compounds with Ni2O3 in promoting the formation of the residual char during combustion. The investigation on the promotion mechanism showed that halide radical releasing from halogen-containing additives worked as a catalyst to accelerate dehydrogenation-aromatization of degradation products of PR which promote the degradation products to form the residual char catalyzed by nickel catalyst.
Resumo:
According to their molecular mass and ESI-MSn data, the trace alkaloid isomers pseudostrychnine and strychnine N-oxide in extracts of the total alkaloids from Strychnos nux-vomical were qualitatively analyzed by electrospray ionization tandem mass spectrometry (ESI-MSn) method after rough silica gel-column chromatographic separation. We also investigated the relationship between their fragmentation mechanism and structures of the two alkaloid isomers. A new method for quickly and highly sensitively analyzing the two alkaloid isomers was proposed.
Resumo:
To improve the reproducibility, stability, and sensitivity of bismuth film electrode (BiFE), we studied the performances of a mixed coating of two cation-exchange polymers, Nafion (NA) and poly(sodium 4-styrenesulfonate) (PSS), modified glassy carbon BiFE (GC/NA-PSS/BiFE). The characteristics of GC/NA-PSS/BiFE were investigated by scanning electron microscopy and cyclic voltammetry. Various parameters were studied in terms of their effect on the anodic stripping voltarnmetry (ASV) signals. Under optimized conditions, the limits of detection were 71 ng L-1 for Cd(II) and 93 ng L-1 for Pb(II) with a 10 min preconcentration. The results exhibited that GC/NA-PSS/BiFE can be a reproducible and robust toot for monitor of trace metals by ASV rapidly and environmentally friendly, even in the presence of surface-active compounds.
Resumo:
Sequential extraction procedures were widely applied for speciation of radioactive elements. In this study, the sequential extraction procedure developed by Martinez-Aguirre was employed for quantification of different chemical forms of thorium in the soil. The total amount of thorium in contaminated soil was much higher by four-fold than the local background value. The soil properties affect the amount of thoriurn and distribution of fractions in contaminated soil. Results showed that the proportion of thorium in soils from Baotou was found as the residual fraction (F5 + F6) > absorbed fraction (F3), coprecipitated fraction (F4) > carbonates fraction (172) and exchangeable fraction (F1) that could be available to plants. The recovery, calculated by ratio of the sum of the six fractions to the pseudo-total content of thorium, was in the range from 96% to 110%. A comparison was carried out between the sequential extraction and the single extraction to evaluate the selectivity of the extractants. It was found that the amount of thorium of absorbed fraction (H) was higher in the single extraction than that estimated in the sequential extraction, possibly duo to transform of the labile form. While for non-residual fraction analysis, the single extraction scheme was a desirable alternative to the sequential extraction procedure.
Resumo:
The speciation and distribution of Zn(II) and the effect of Gd(III) on Zn(II) speciation in human blood plasma were studied by computer simulation. The results show that, in normal blood plasma, the most predominant species of Zn(II) are [Zn(HSA)] (58.2%), [Zn(IgG)](20.1%), [Zn(Tf)] (10.4%), ternary complexes of [Zn(Cit)(Cys)] (6.6%) and of [Zn(Cys)(His)H] (1.6%), and the binary complex of [Zn(CYS)(2)H] (1.2%). When zinc is deficient, the distribution of Zn(II) species is similar to that in normal blood plasma. Then, the distribution changes with increasing zinc(II) total concentration. Overloading Zn(II) is initially mainly bound to human serum albumin (HSA). As the available amount of HSA is exceeded, phosphate metal and carbonate metal species are established. Gd(III) entering human blood plasma predominantly competes for phosphate and carbonate to form precipitate species. However, Zn(II) complexes with phosphate and carbonate are negligible in normal blood plasma, so Gd(III) only have a little effect on zinc(II) species in human blood plasma at a concentration above 1.0x10(-4) M.
Resumo:
In this work, a method was established for the determination of impurities in high purity tellurium by inductively coupled plasma mass spectrometry (ICP-MS) after Fe(OH)(3) coprecipitation. After comparison of coprecipitation ability and separation efficiency between Fe(OH), and Al(OH)(3), Fe(OH)(3) was chosen as the precipitate. A separation factor of 160 for 200 mg tellurium was obtained under conditions of pH 9 and 2 mg of Fe3(+). The 13 elements, such as Bi, Sn, Pb, In, Tl, Cd, Cu, Co, Ni, Zn, Ti, Be and Zr, could be almost completely coprecipitated under these conditions. In addition, Te memory effect imposed on the ICP-MS instrument was assessed, as well as Te matrix effect that caused the low recovery of Ga, As, Sb and V in real sample was discussed. Finally, the method was evaluated through recovery test and was applied to practical sample analysis, with detection limits of most of the elements being below 0.15 mug g(-1) and R.S.D. below or at approximately 10%, which indicated that this method could fully satisfy the requirements for analysis of 99.999% similar to 99.9999% high purity Te.
Resumo:
Major, minor and trace elemental contents in northeast China soybeans were determined by using inductively, coupled plasma atomic emission spectrometry (ICP-AES). Three different sample digestion methods including two wet digestions, HNO3-HClO4 and HNO3-H2SO4 and a dry ash method were compared. Owing to the high oil content in soybeans, long time is needed and access acid should be added, with mixed acid digestion methods, which may result in higher sample blank. Therefore, the dry ask method would be more proper for the pre-treatment of soybean samples. Potassium and phosphorus are major elements in soybeans, so the effect of potassium and phosphorus on the other elements was investigated. Results showed that the potassium and phosphorus did not affect the determination. of other trace elements. There are not significant differences in trace elemental contents for the eleven northeast China soybeans.
Resumo:
A new chemiluminescence(CL) system for the determination of ascorbic acid has been established. By the fast reduction reaction between chromium(VI) and ascorbic acid, chromium(M was generated to react with luminol and hydrogen peroxide in alkaline aqueous solution and hydrogen peroxide to produce CL. The CL emission intensity was correlated with ascorbic acid concentration in the range 8.0 x 10(-9) to 1.6 x 10(-4) mol/L, and the detection limit was 8.0 x 10(-9) mol/L ascorbic acid. The relative standard deviation (n = 11) for 1.0 x 10(-6) mol/L ascorbic acid is 0.9%. The method has been applied to the determination of ascorbic acid in vitamin C tablets with satisfactory results.
Resumo:
Using the Bridgeman-Stockbarger method, the KMgF3:EU2+ single crystal was grown. The color centers in unirradiated KMgF3:Eu crystal were studied. By thermal annealing, we confirmed the 422-nm emission resulted from color centers and oxygen centers, and we proved the energy transfer from EU2+ to color centers. From spectra, the relative oxygen content in crystal was calculated, and the relationships of oxygen displacing fluorine were studied.
Resumo:
Inductively coupled plasma mass spectrometry (ICP-MS),a highly sensitive inorgnic analytic technique,fits to determine ultra-nace rare-earth elements in human plasma. Under the optimized conditions detection limits for 15 rare-earth elements are in the range of 0.7 (for Eu)-5.4 (for Gd) ng.L-1. Indium as an internal standard element is used to compensate for matrix suppression effect and sensitivity drift. Three kinds of preparation methods, diluted with 1% HNO3, digested with HNO3-H2O2 and with HNO3-HClO4, are checked and compared,and the former is the simplest way to be measured. The samples diluted with 1% HNO3, stored in 4 degrees C, are very steady for 16 days. With the method, 11 healthy plasma samples in Changchun area of China are analysed.