110 resultados para Side pump


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two semiconductor saturable absorber mirrors (SESAMs), of which one is coated with 50% reflection film on the top and the other is not, were contrastively studied in passively mode-locked solid-state lasers which were pumped by low output power laser diode (LD). Experiments have shown that reducing the modulation depth of SESAM by coating partial reflection film, whose reflectivity is higher than that between SESAM and air interface, is an effective method to get continuous wave (CW) mode-locking instead of Q-switched mode-locking (QML) in low power pumped solid-state lasers. A simple Nd:YVO4 laser pumped by low power LD, in which no water-cooling system was used, could obtain CW mode-locking by the 50% reflector coated SESAM with average output power of ~ 20 mW

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel design of 100GHz-spaced 16channel arrayed-waveguide grating (AWG) based on silica-on-silicon chip is reported.AWG is achieved by adding a Y-branch to the AWG and arranging the input/output channel in a neat row,so the whole configuration can be aligned and packaged using only one fiber-array.This configuration can decrease the device's size,enlarge the minimum radius of curvature,save time on polishing and alignment,and reduce the chip's fabrication cost.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report an LD side-pumped continuous-wave passive mode-locked Nd:YAG laser with a Z-type folded cavity based on a semiconductor saturable absorber mirror (SESAM). The average output power 2.95 W of mode-locked laser with electro-optical conversion efficiency of 1.3% and high beam quality (M-x(2) = 1.25 and M-y(2) = 1.22) is achieved. The repetition rate of mode-locked pulse of 88 MHz with pulse energy of 34 nJ is obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

硅微条探测器通过微电子工艺制作,易因沾污导致性能下降甚至失效;裸露的键合引线,也易因机械力形成隐性或显性失效。对上述现象的研究可用于修复、维护探测器并在设计和工艺流程中改进其性能。本文通过光学、电气手段分析其结构和制作工艺流程,根据沾污性质在不同条件下清洗探测器,中测后根据芯片图形、封装方式和电气要求修复探测器,最后采用同位素α能谱测试修复效果。对一块沾污后失效(无法加载偏压)的硅微条清洗后在大气环境,N面接地,P面加载负偏压条件下进行了测试,结果显示:170 V全耗尽,平均漏电流2.94μA,5.486 MeV的α峰能量分辨率约1.28%。失效键合所在条的另一面各条能谱观测到假峰,键合修复后消除。因沾污失效的硅微条探测器经过合适的清洗、修复,部分可以恢复性能,但清洗对表面和结构有损伤,须谨慎。另外,键合失效后,因信号不能引出导致的电荷积累会通过电容效应影响其它灵敏区。文章提示,探测器应存放于洁净,恒温,低湿度,避光,避强电磁干扰的环境,以提高能量和位置分辨率,并增加工作稳定性,延长使用寿命。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A packed-bed electroosmotic pump (EOP) was constructed and evaluated. The EOP consisted of three capillary columns packed in parallel, a gas-releasing device, Pt electrodes and a high-voltage power supply. The EOP could generate output pressure above 5.0 MPa and constant flow rate in the range of nl/min to a few mul/min for pure water, pure methanol, 2 mM potassium dihydrogenphosphate buffer, the buffer-methanol mixture and the pure water-methanol mixture at applied potentials less than 20 W The composition of solvent before/after pumping was quantitatively determined by using a gas chromatograph equipped with both flame ionization detector and thermal conductivity detector. It was found that there were no apparent changes in composition and relative concentrations after pumping process for a methanol-ethanol-acetonitrile mixture and a methanol-water mixture. Theoretical aspect of the EOP was discussed in detail. An capillary HPLC system consisting of the EOP, an injection valve, a 15 cm x 320 mum i.d., 5 mum Spherigel C(18) stainless steel analytical column, and an on-column UV detector was connected to evaluate the performance of the EOP. A comparative study was also carried out with a mechanical capillary HPLC pump on the same system. The results demonstrated that the reproducibility of flow rate and the pulsation-free flow property of the EOP are superior to that of mechanical pump in capillary HPLC application. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An electroosmotic pump (EOP) capable of generating pressure above 3 MPa and mul/min flow rate with reverse phase mobile phases of HPLC was constructed and evaluated. The pump consisted of three parallel connected fused silica capillary columns (25 cm x 320 mum I.D.) packed with 2 mum silica materials, hollow electrodes, a high voltage DC power supply, and. a liquid pressure transducer. The EOP was applied in a capillary liquid chromatographic system for mobile phase delivery instead of a mechanical pump. Standard samples containing thiourea, naphthalene, anthracene, phenanthrene and acetonitrile were separated on a 15 cm x 320 mum I.D. 5 mum Chromasil C-18 packed capillary column with acetonitrile/water as mobile phase. (C) 2003 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The multi-photon dissociative photoionization dynamics of CF3I has been studied with femtosecond two-color pump-probe time-of-flight mass spectra at a pump pulse of 265 nm and a probe pulse of 398 nn. This enables the A band and 5ppi(3)7ssigma((2)Pi(1/2)) Rydberg state to be accessed with the pump beam. The observed fast and slow decay components of CF3+ and I+ reflect the fast repulsive A band and some higher lying ion-pair states may be responsible for the decay of the 5ppi(3)7ssigma((2)Pi(1/2)) Rydberg state. The results provide information on the different multi-photon pathways producing these ions and the de-excitation mechanism of the 5ppi(3)7ssigma((2)Pi(1/2)) Rydberg state. (C) 2003 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Various analytical physical models are presented to extract the photodissociation dynamics information from the data obtained in the femtosecond pump-probe experiment. The single- and double-component models are employed to explain the single- and double-channel dissociation of parent molecules. Another single-component model for fragment dissociation or deexcitation is also presented. All cases are explanatorily demonstrated on the pump-probe experimental data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work reports on the design and performance evaluation of a miniature direct methanol fuel cell(DMFC)integrated with an electro_osmotic(EO)pump for methanol delivery.Electro-osmotic pumps require minimal parasitic power while boasting no moving parts and simple fuel cell integration.Here ,aneletro-osmotic pump is realized from a commercially available porous glass frit.We characterize a custom-fabricated DMFC with a free convection cathode and coupled to an extennal electro-osmotic pump operated at applied potentials of 4.0,7.0,and 10V.Maximum gross power density of our free convection DMFC(operated at 50°)is 55 mW/cm2 using 4.0 mol/L concentration methanol solution supplied by the EO pump.Experimental results show that electro-osmotic pumps can deliver 2.0,4.0 and 8.0mol/L methanol/water mixtures to DMFCs while utilizing ~5.0% of the fuel cell power.Furthermore ,we discuss pertinent design considerations when using electro-osmotic pumps with DMFCs and areas of further study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aqueous conducting polyaniline dispersion was prepared employing acidic phosphate ester bearing hydrophilic ethylene glycol segment as dopant, and conducting film with electrical conductivity of 25 S/cm was obtained from the dispersion. Ordered self-assembly lamellar structure with interlamellar distance of 1.2 nm was observed in the film, which consisted of alternating layers of rigid polyaniline chain and flexible phosphate ester side chains, where the phosphate side chain layer was separated by two rigid polyaniline layers. The lamellar structure leading to high conducting film was formed due to the confinement of polyaniline chain by crystallizable phosphate side chain, since the electrical conductivity decreased by four orders of magnitude once the dopant side chain crystalline was destroyed. The crystallizable side chain forced lamellar structure is expected to be a new chance for highly conducting polyaniline.