208 resultados para Plasma diagnostic


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thin foil observations using transmission electron microscopy reveal that the density of dislocations within the band is extremely high and the tangled arrangement of dislocations tends to align along the length of the shear band. The grains in the band were also elongated along the shear band and clearly exhibited a crystallographic nature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A variational method is developed to find approximate solutions to the generalized Grad-Shafranov equations for an adiabatic compression of the plasma with toroidal rotation, via the expansion in Fourier series in poloidal angle of the flux surface coordinates. The numerical results, which are carried out by the present method and by the usual two-dimensional method for a static equilibrium state, agree well.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A variational method is developed for adiabatic compression of plasma with both poloidal and toroidal rotation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The T. E. wave in cylindrical wavegulde filled with inhomogeneous plasma immersed in the external uniform longitudinal magnetic field is investigated. The analytic solution expressed in polynomial formed by cutting the confluent hypergeometric function is obtained. Furthermore the eigenfrequency of T. E. wave is obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The stationary two-dimensional (x, z) near wakes behind a flat-based projectile which moves at a constant mesothermal speed (V∞) along a z-axis in a rarefied, fully ionized, plasma is studied using the wave model previously proposed by one of the authors (VCL). One-fluid theory is used to depict the free expansion of ambient plasma into the vacuum produced behind a fast-moving projectile. This nonstationary, one-dimensional (x, t) flow which is approximated by the K-dV equation can be transformed, through substitution, t=z/V∞, into a stationary two-dimensional (x, z) near wake flow seen by an observer moving with the body velocity (V∞). The initial value problem of the K-dV equation in (x, t) variables is solved by a specially devised numerical method. Comparisons of the present numerical solution for the asymptotically small and large times with available analytical solutions are made and found in satisfactory agreements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The influence of non-equilibrium plasma layer pressure and thickness on the transmission of microwave is considered when the incidence of wave is at an arbitrary angle. The plasma is cold, weakly ionized, and steady-state. It is assumed that it is a layered media with a kind of distribution of electron number density and the microwave is a plane wave. The results show that the pressure of plasma affects the absorption of microwave deeply, and the thickness relatively weakly in a non-equilibrium plasma slab.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experimentally observed, results are presented for the DCarcplasmajets and theirarc-rootbehaviors generated atreduced gas pressure and without or with an' applied magnetic field. Pure argon, argon -hydrogen or argon-nitrogen mixture is used as the plasma-forming gas. A specially designed copper mirror is constructed and used for better observing the arc-root behavior on the anode surface of the DC non-transferred arcplasma torch. It is shown that for the cases without applied magnetic field, the laminar plasmajets are stable and approximately axisymmetrical. The arc-root attachment on the anode surface is completely diffusive when argon is used as the plasma-forming gas, while the arc-root attachment often becomes constrictive when hydrogen or nitrogen is added into the argon. When an external magnetic field is applied, the arcroot tends to rotate along the anode surface of the non-transferred arcplasma torch.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Composite coatings were obtained on A3 steel by hot dipping aluminum(HAD) at 720 degreesC for 6 min and micro-plasma oxidation (MPO) in alkali electrolyte. The surface morphology, element distribution and interface structure of composite coatings were studied by means of XRD, SEM and EDS. The results show that the composite coatings obtained through HAD/MPO on A3 steel consist of four layers. From the surface to the substrate, the layer is loose Al2O3 ceramic, compact Al2O3 ceramic, At and FeAl intermetallic compound layer in turn. The adhesions among all the layers are strengthened because the ceramic layer formed at the At surface originally, FeAl intermetallic compound layer and substrate are combined in metallurgical form through mutual diffusion during HAD process. Initial experiment results disclose that the anti-corrosion performance and wear resistance of composite coating are obviously improved through HAD/MPO treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A gliding arc discharge  plasma and its characteristics are
described. Analysis on the production principle of the plasma is presented. 
Some experimental results about two  novel types  of the gliding arc plasma generator were obtained. These types of gliding arc plasma are potentially used in chemical industry and environment engineering.