121 resultados para Parallel mechanics


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Muntjac deer (Muntiacinae, Cervidae) are of great interest in evolutionary studies because of their dramatic chromosome variations and recent discoveries of several new species. In this paper, we analyze the evolution of karyotypes of muntjac deer in the context of a phylogeny which is based on 1,844-bp mitochondrial DNA sequences of seven generally recognized species in the muntjac subfamily. The phylogenetic results support the hypothesis that karyotypic evolution in muntjac deer has proceeded via reduction in diploid number. However, the reduction in number is not always linear, i.e., not strictly following the order: 46-->14/13-->8/9-->6/7. For example, Muntiacus muntjak (2n = 6/7) shares a common ancestor with Muntiacus feae (2n = 13/14), which indicates that its karyotype was derived in parallel with M. feae's from an ancestral karyotype of 2n greater than or equal to 13/14. The newly discovered giant muntjac (Muntiacus vuquangensis) may represent another pa;allel reduction lineage from the ancestral 2n = 46 karyotype. Our phylogenetic results indicate that the giant muntjac is relatively closer to Muntiacus reevesi than to other muntjacs and may be placed in the genus Muntiacus. Analyses of sequence divergence reveal that the rate of change in chromosome number in muntjac deer is one of the fastest in vertebrates. Within the muntjac subfamily, the fastest evolutionary rate is found in the Fea's lineage, in which two species with different karyotypes diverged in around 0.5 Myr.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

本文选用经过实验验证的碱基序列 ,用简化的方式 ,构建了被水分子和镁离子修饰的核酸序列的分子模型 ,应用分子力学模拟方法对序列进行能量优化 ,对优化后序列的构象参数、成键状况和能量数据等进行了分析。对tRNAHHis GUG的识别特性作了初步的探索 ,得到了和实验结果相近的结论。此外 ,还从能力学的角度讨论了溶剂 -溶质 -溶剂相互作用形成的网状氢键网络对核酸结构稳定性的影响 ,探讨了非Crick_WatsonGU、UU配对的能力学特征并存在于被水分子和镁离子修饰的核酸序列中的GU、UU配对情况。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Parallel strand models for base sequences d(A)(10). d(T)(10), d(AT)(5) . d(TA)(5), d(G(5)C(5)). d(C(5)G(5)), d(GC)(5) . d(CG)(5) and d(CTATAGGGAT). d(GATATCCCTA), where reverse Watson-Crick A-T pairing with two H-bonds and reverse Watson-Crick G-C pairing with one H-bond or with two H-bonds were adopted, and three models of d(T)(14). d(A)(14). d(T)(14) triple helix with different strand orientations were built up by molecular architecture and energy minimization. Comparisons of parallel duplex models with their corresponding B-DNA models and comparisons among the three triple helices showed: (i) conformational energies of parallel AT duplex models were a little lower, while for GC duplex models they were about 8% higher than that of their corresponding B-DNA models; (ii) the energy differences between parallel and B-type duplex models and among the three triple helices arose mainly from base stacking energies, especially for GC base pairing; (iii) the parallel duplexes with one H-bond G-C pairs were less stable than those with two H-bonds G-C pairs. The present paper includes a brief discussion about the effect of base stacking and base sequences on DNA conformations. (C) 1997 Academic Press Limited.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-quality Ge film was epitaxially grown on silicon on insulator using the ultrahigh vacuum chemical vapor deposition. In this paper, we demonstrated that the efficient 1 4 germanium-on-silicon p-i-n photodetector arrays with 1.0 mu m Ge film had a responsivity as high as 0.65 A/W at 1.31 mu m and 0.32 A/W at 1.55 mu m, respectively. The dark current density was about 0.75 mA/cm(2) at 0 V and 13.9 mA/cm(2) at 1.0 V reverse bias. The detectors with a diameter of 25 mu m were measured at 1550 nm incident light under 0 V bias, and the result showed that the 3-dB bandwidth is 2.48 GHz. At a reverse bias of 3 V, the bandwidth is about 13.3 GHz. The four devices showed a good consistency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show that the Coulomb blockade in parallel dots pierced by magnetic flux Phi completely blocks the resonant current for any value of Phi except for integer multiples of the flux quantum Phi(0). This non-analytic (switching) dependence of the current on Phi arises only when the dot states that carry the current are of the same energy. The time needed to reach the steady state, however, diverges when Phi -> n Phi(0). Copyright (C) EPLA, 2009

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A programmable vision chip with variable resolution and row-pixel-mixed parallel image processors is presented. The chip consists of a CMOS sensor array, with row-parallel 6-bit Algorithmic ADCs, row-parallel gray-scale image processors, pixel-parallel SIMD Processing Element (PE) array, and instruction controller. The resolution of the image in the chip is variable: high resolution for a focused area and low resolution for general view. It implements gray-scale and binary mathematical morphology algorithms in series to carry out low-level and mid-level image processing and sends out features of the image for various applications. It can perform image processing at over 1,000 frames/s (fps). A prototype chip with 64 x 64 pixels resolution and 6-bit gray-scale image is fabricated in 0.18 mu m Standard CMOS process. The area size of chip is 1.5 mm x 3.5 mm. Each pixel size is 9.5 mu m x 9.5 mu m and each processing element size is 23 mu m x 29 mu m. The experiment results demonstrate that the chip can perform low-level and mid-level image processing and it can be applied in the real-time vision applications, such as high speed target tracking.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new device of two parallel distributed feedback (DFB) lasers integrated monolithically with Y-branch waveguide coupler was fabricated by means of quantum well intermixing. Optical microwave signal was generated in the Y-branch waveguide coupler through frequency beating of the two laser modes coming from two DFB laser in parallel, which had a small difference in frequency. Continuous rapid tuning of optical microwave signal from 13 to 42 GHz were realized by adjusting independently the driving currents injected into the two DFB lasers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have studied the equilibrium and nonequilibrium electronic transports through a double quantum dot coupled to leads in a symmetrical parallel configuration in the presence of both the inter- and the intradot Coulomb interactions. The influences of the interdot interaction and the difference between dot levels on the local density of states (LDOS) and the differential conductance are paid special attention. We find an interesting zero-bias maximum of the differential conductance induced by the interdot interaction, which can be interpreted in terms of the LDOS of the two dots. Due to the presence of the interdot interaction, the LDOS peaks around the dot levels epsilon(i) are split, and as a result, the most active energy level which supports the transport is shifted near to the Fermi level of the leads in the equilibrium situation. (c) 2006 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Guest host polymer thin films of polymethyl methacrylate (PMMA) incorporated with (4'-nitrobenzene)-3-azo-9-ethylcarbazole (NAEC) were fabricated by spin coating and then poled by the method of corona-onset poling at elevated temperature. The absorption mechanism of the polymeric film, which is very important for the optical transmission losses and directly relates to the orientation of chromophore NAEC in polymer PMMA, was investigated in detail. From the UV-visible absorption spectra for NAEC/PMMA film before and after being poled, we determined the change of absorption coefficient kappa with the wavelength and approximately calculated the maximum absorption A(parallel tomax) as 3.46 for incident light propagating parallel through the film, i.e. the ordinary polarized light, which cannot be directly measured in the spectro photometer. (C) 2002 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A parallel optical communication subsystem based on a 12 channels parallel optical transmitter module and a 12 channels parallel optical receiver module can be used as a 10Gbps STM-64 or an OC-192 optical transponder. The bit error rate of this parallel optical communication subsystem is about 0 under the test by SDH optical transport tester during three hours and eighteen minutes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new 12 channels parallel optical transmitter module in which a Vertical Cavity Surface Emitting Laser (VCSEL) has been selected as the optical source is capable of transmitting 37.5Gbps date over hundreds meters. A new 12 channels parallel optical receiver module in which a GaAs PIN (p-intrinsic-n-type) array has been selected as the optical receiver unit is capable of responding to 30Gbps date. A transmission system based on a 12 channels parallel optical transmitter module and a 12 channels parallel optical receiver module can be used as a 10Gbps STM-64 or an OC-192 optical transponder. The parallel optical modules and the parallel optical transmission system have passed the test in laboratory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the design process and performance of the optimized parallel optical transmission module. Based on 1x12 VCSEL (Vertical Cavity Surface Emitting Laser) array, we designed and fabricated the high speed parallel optical modules. Our parallel optical module contains a 1x12 VCSEL array, a 12 channel CMOS laser driver circuit, a high speed PCB (Printed Circuit Board), a MT fiber connector and a packaging housing. The L-I-V characteristics of the 850nm VCSEL was measured at the operating current 8mA, 3dB frequency bandwidth more than 3GHz and the optical output 1mW. The transmission rate of all 12 channels is 30Gbit/s, with a single channel 2.5Gbit/s. By adopting the integration of the 1x12 VCSEL array and the driver array, we make a high speed PCB (Printed Circuit Board) to provide the optoelectronic chip with the operating voltage and high speed signals current. The LVDS (Low-Voltage Differential Signals) was set as the input signal to achieve better high frequency performance. The active coupling was adopted with a MT connector (8 degrees slant fiber array). We used the Small Form Factor Pluggable (SFP) packaging. With the edge connector, the module could be inserted into the system dispense with bonding process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a novel and innovative scheme for 10Gb/s parallel Very Short Reach (VSR) optical communication system. The optimized scheme properly manages the SDH/SONET redundant bytes and adjusts the position of error detecting bytes and error correction bytes. Compared with the OIF-VSR4-01.0 proposal, the scheme has a coding process module. The SDH/SONET frames in transmission direction are disposed as follows: (1) The Framer-Serdes Interface (FSI) gets 16x622.08Mb/s STM-64 frame. (2) The STM-64 frame is byte-wise stripped across 12 channels, all channels are data channels. During this process, the parity bytes and CRC bytes are generated in the similar way as OIF-VSR4-01.0 and stored in the code process module. (3) The code process module will regularly convey the additional parity bytes and CRC bytes to all 12 data channels. (4) After the 8B/10B coding, the 12 channels is transmitted to the parallel VCSEL array. The receive process approximately in reverse order of transmission process. By applying this scheme to 10Gb/s VSR system, the frame size in VSR system is reduced from 15552x12 bytes to 14040x12 bytes, the system redundancy is reduced obviously.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper studies the development of a real-time stereovision system to track multiple infrared markers attached to a surgical instrument. Multiple stages of pipeline in field-programmable gate array (FPGA) are developed to recognize the targets in both left and right image planes and to give each target a unique label. The pipeline architecture includes a smoothing filter, an adaptive threshold module, a connected component labeling operation, and a centroid extraction process. A parallel distortion correction method is proposed and implemented in a dual-core DSP. A suitable kinematic model is established for the moving targets, and a novel set of parallel and interactive computation mechanisms is proposed to position and track the targets, which are carried out by a cross-computation method in a dual-core DSP. The proposed tracking system can track the 3-D coordinate, velocity, and acceleration of four infrared markers with a delay of 9.18 ms. Furthermore, it is capable of tracking a maximum of 110 infrared markers without frame dropping at a frame rate of 60 f/s. The accuracy of the proposed system can reach the scale of 0.37 mm RMS along the x- and y-directions and 0.45 mm RMS along the depth direction (the depth is from 0.8 to 0.45 m). The performance of the proposed system can meet the requirements of applications such as surgical navigation, which needs high real time and accuracy capability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper studies the development of a real-time stereovision system to track multiple infrared markers attached to a surgical instrument. Multiple stages of pipeline in field-programmable gate array (FPGA) are developed to recognize the targets in both left and right image planes and to give each target a unique label. The pipeline architecture includes a smoothing filter, an adaptive threshold module, a connected component labeling operation, and a centroid extraction process. A parallel distortion correction method is proposed and implemented in a dual-core DSP. A suitable kinematic model is established for the moving targets, and a novel set of parallel and interactive computation mechanisms is proposed to position and track the targets, which are carried out by a cross-computation method in a dual-core DSP. The proposed tracking system can track the 3-D coordinate, velocity, and acceleration of four infrared markers with a delay of 9.18 ms. Furthermore, it is capable of tracking a maximum of 110 infrared markers without frame dropping at a frame rate of 60 f/s. The accuracy of the proposed system can reach the scale of 0.37 mm RMS along the x- and y-directions and 0.45 mm RMS along the depth direction (the depth is from 0.8 to 0.45 m). The performance of the proposed system can meet the requirements of applications such as surgical navigation, which needs high real time and accuracy capability.