382 resultados para Langmuir-Schaefer (LS)


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The ionization kinetics of sodium diluted in argon is studied in a shock tube, in which the test gas mixture is ionized by a reflected shock wave and subsequently quenched by a strong rarefaction wave. A Langmuir electrostatic probe is used to monitor the variation of the ion number density at the reflection shock wave region. The working state of the probe is in the near fi-ee fall region and a correction for reduction of the probe current due to elastic scattering in the probe sheath is introduced. At the temperature range of 800 to 2600 K and in the ambience of argon gas, the three-body recombination rate coefficient of the sodium ion with electron is determined: 3.43 x 10(-14)T(-3.77) cm(6).s(-1).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

在涂敷有聚合物PEI涂层的单晶硅表面上制备了HFBA单层分子膜,接触角测量及XPS结果表明,HFBA在PEI表面产生了化学吸附发生了化学键合(酰胺键),形成了低表面能的HFBA单分子层膜.这一吸附反应的动力学行为可能表现为Langmuir单分子层化学吸附.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

以爆炸排淤填石法为背景,对不同应变率阶段淤泥的本构模型进行了分析,利用ANSYS/LS-DYNA动态有限元分析程序对所选择的模型进行验证和确认.计算和分析结果表明:在形成爆炸空腔的高应变率阶段,淤泥表现为理想不可压缩流体的性质;在小药量小抵抗线条件下,甚至在淤泥自重作用下的较低应变率变形阶段,其黏性效应也可以忽略不计.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

以爆炸排淤填石法为背景,对相关岩土介质的本构模型进行了探讨。分析认为,在以LS.DYNA 动态有限元分析程序对爆炸排淤填石法的数值模拟中,岩土介质不适于采用Mohr.Coulomb 模型,堆石体宜采用Drucker-Prager 模型,淤泥宜采用Prandtl-Reuss 模型;利用LS-DYNA 程序对淤泥的本构模型进行了验证和确认,计算表明:在形成爆炸空腔的高应变率阶段,淤泥表现为理想不可压缩流体的性质;在小药量小抵抗线条件下,在淤泥自重作用下的低应变率变形阶段,其粘性效应可以忽略不计。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

By means of experiments of instability of a uniform cylindrical soap film, Boys had showed that the bubble molded by the film is unstable when its length is greater than its circumference. Recently that is generally called the Rayleigh Criterion. In this paper, a linear theory in hydrodynamics is applied to analyze the stability of the cylindrical soap film supported by two equal size disks; all conditions of the stationary wave on the end plates of two disks are given. From here we get that the Rayleigh Criterion on the stability of the cylindrical soap film is proved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

利用测量强激波波后N2+第一负系(0,0)带和(1,2)带的辐射,对强激波后振动温度历程的测量过程进行了探索,并利用Langmuir探针技术,在低密度激波管中对强激波后电子数密度历程进行了测量.测量和计算结果进行了对比.结果表明:N2+B2∑u+态的激发比振动能的激发更快;实验测得的振动温度有明显的周期性振荡;在激波速度7.65~7.85km/s、p1=1.33Pa、实验段内径0.8m下,实验有效时间只有约6.5μs,实验中的电子数密度不能达到峰值.在约10倍波前自由程的实验有效区域内,电子数密度的测量值与计算值吻合很好.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To study electron affinity kinetics, a shock tube method was applied, in which the test gas was ionized by a reflected shock wave and subsequently quenched by a strong rarefaction wave. As the quenching speed of 106 K/s was reached, a nonequilibrium ionization-recombination process occurred, which was dominated by ion recombination with electrons. A Langmuir electrostatic probe was used to monitor variation in the ion number density at the reflection shock region. The working state of the probe was analyzed...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

冷弯成型变形复杂,事先难以预测其变形效果.根据冷弯成型的特点和变形规律设计出基于万能实验机上的局部大变形测试装置,并应用此装置对冷弯成型过程进行回弹分析,为冷弯成型理论分析和使用ANSYS/LS-DYNA对冷弯成型分析提供科学依据.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

利用数值仿真软件LS-DYNA3D,通过数值模拟方法研究了药型罩压跨、射流的形成、延伸和失稳断裂的全过程,数值模拟结果与实验结果吻合较好,得到了一套实用的数值模拟方法及材料模型参数,定性分析了大锥角的药型罩压垮过程,对形成杆式射流的药型罩结构设计具有一定借鉴意义.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, the penetration process of ogive-nose projectiles into the semi-infinite concrete target is investigated by the dimensional analysis method and FEM simulation. With the dimensional analysis, main non-dimensional parameters which control the penetration depth are obtained with some reasonable hypothesis. Then, a new semi-empirical equation is present based on the original work of Forrestal et al., has only two non-dimensional combined variables with definite physical meanings. To verify this equation, prediction results are compared with experiments in a wide variation region of velocity. Then, a commercial FEM code, LS-DYNA, is used to simulate the complex penetration process, that also show the novel semi-empirical equation is reasonable for determining the penetration depth in a concrete target.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the electromagnetic wave propagation characteristics in plasma and the attenuation coefficients of the microwave in terms of the parameters n(e), v, w, L, w(b). The phi800 mm high temperature shock tube has been used to produce a uniform plasma. In order to get the attenuation of the electromagnetic wave through the plasma behind a shock wave, the microwave transmission has been used to measure the relative change of the wave power. The working frequency is f = (2 similar to 35) GHz (w = 2pif, wave length lambda = 15 cm similar to 8 mm). The electron density in the plasma is n(e) = (3 x 10(10) similar to 1 x 10(14)) cm(-3). The collision frequency v = (1 x 10(8) similar to 6 x 10(10)) Hz. The thickness of the plasma layer L = (2 similar to 80) cm. The electron circular frequency w(b) = eB(0)/m(e), magnetic flux density B-0 = (0 similar to 0.84) T. The experimental results show that when the plasma layer is thick (such as L/lambda greater than or equal to 10), the correlation between the attenuation coefficients of the electromagnetic waves and the parameters n(e), v, w, L determined from the measurements are in good agreement with the theoretical predictions of electromagnetic wave propagations in the uniform infinite plasma. When the plasma layer is thin (such as when both L and lambda are of the same order), the theoretical results are only in a qualitative agreement with the experimental observations in the present parameter range, but the formula of the electromagnetic wave propagation theory in an uniform infinite plasma can not be used for quantitative computations of the correlation between the attenuation coefficients and the parameters n(e), v, w, L. In fact, if w < w(p), v(2) much less than w(2), the power attenuations K of the electromagnetic waves obtained from the measurements in the thin-layer plasma are much smaller than those of the theoretical predictions. On the other hand, if w > w(p), v(2) much less than w(2) (just v approximate to f), the measurements are much larger than the theoretical results. Also, we have measured the electromagnetic wave power attenuation value under the magnetic field and without a magnetic field. The result indicates that the value measured under the magnetic field shows a distinct improvement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The existing theories dealing with the evaluation of the absolute coagulation rate constant by turbidity measurement were experimentally tested for different particle-sized (radius = a) suspensions at incident wavelengths (lambda) ranging from near-infrared to ultraviolet light. When the size parameter alpha = 2 pi a/lambda > 3, the rate constant data from previous theories for fixed-sized particles show significant inconsistencies at different light wavelengths. We attribute this problem to the imperfection of these theories in describing the light scattering from doublets through their evaluation of the extinction cross section. The evaluations of the rate constants by all previous theories become untenable as the size parameter increases and therefore hampers the applicable range of the turbidity measurement. By using the T-matrix method, we present a robust solution for evaluating the extinction cross section of doublets formed in the aggregation. Our experiments show that this new approach is effective in extending the applicability range of the turbidity methodology and increasing measurement accuracy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Our previous studies have shown that the determination of coagulation rate constants by turbidity measurement becomes impossible for a certain operating wavelength (that is, its blind point) because at this wavelength the change in the turbidity of a dispersion completely loses its response to the coagulation process. Therefore, performing the turbidity measurement in the wavelength range near the blind point should be avoided. In this article, we demonstrate that the turbidity measurement of the rate constant for coagulation of a binary dispersion containing particles of two different sizes (heterocoagulation) presents special difficulties because the blind point shifts with not only particle size but also with the component fraction. Some important aspects of the turbidity measurement for the heterocoagulation rate constant are discussed and experimentally tested. It is emphasized that the T-matrix method can be used to correctly evaluate extinction cross sections of doublets formed during the heterocoagulation process, which is the key data determining the rate constant from the turbidity measurement, and choosing the appropriate operating wavelength and component fraction are important to achieving a more accurate rate constant. Finally, a simple scheme in experimentally determining the sensitivity of the turbidity changes with coagulation over a wavelength range is proposed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

本文总结了近几年来在φ800mm激波管上对高温空气电子密度所做的大量测量工作。在ρ_1=1.3—133帕斯卡,M_s=9—22.5的范围内,使用了近自由分子流Langmuir探针、普通微波透射仪、高灵敏度微波透射仪和反射仪、微波干涉仪等对正激波后的电子密度进行了系统地测量。在各种参数状态下,全部实验数据均符合在同一激波马赫数下n_g正比于ρ_1的经验规律。实验测量结果与目前工程上常用的各种理论计算图表进行了对比,验证了这些图表的可用性。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present paper describes a systematic study of argon plasmas in a bell-jar inductively coupled plasma (ICP) source over the range of pressure 5-20 mtorr and power input 0.2-0.5 kW, Experimental measurements as well as results of numerical simulations are presented. The models used in the study include the well-known global balance model (or the global model) as well as a detailed two-dimensional (2-D) fluid model of the system, The global model is able to provide reasonably accurate values for the global electron temperature and plasma density, The 2-D model provides spatial distributions of various plasma parameters that make it possible to compare with data measured in the experiments, The experimental measurements were obtained using a tuned Langmuir double-probe technique to reduce the RF interference and obtain the light versus current (I-V) characteristics of the probe. Time-averaged electron temperature and plasma density were measured for various combinations of pressure and applied RF power, The predictions of the 2-D model were found to be in good qualitative agreement with measured data, It was found that the electron temperature distribution T-e was more or less uniform in the chamber, It was also seen that the electron temperature depends primarily on pressure, but is almost independent of the power input, except in the very low-pressure regime. The plasma density goes up almost linearly with the power input.