88 resultados para HIGH TEST SPEED
Resumo:
A high performance AlAs/In0.53 Ga0.47 As/InAs resonant tunneling diode (RTD) on InP substrate is fabricated by inductively coupled plasma etching. This RTD has a peak-to-valley current ratio (PVCR) of 7. 57 and a peak current density Jp = 39.08kA/cm^2 under forward bias at room temperature. Under reverse bias, the corresponding values are 7.93 and 34.56kA/cm^2 . A resistive cutoff frequency of 18.75GHz is obtained with the effect of a parasitic probe pad and wire. The slightly asymmetrical current-voltage characteristics with a nominally symmetrical structure are also discussed.
Resumo:
Design and fabrication of a parallel optical transmitter are reported. The optimized 12 channel parallel optical transmitter,with each channel's data rate up to 3Gbit/s,is designed, assembled, and measured. A top-emitting 850nm vertical cavity surface emitting laser(VCSEL) array is adopted as the light source,and the VCSEL chip is directly wire bonded to a 12 channel driver IC. The outputs of the VCSEL array are directly butt coupled into a 12 channel fiber array. Small form factor pluggable (SFP) packaging technology is used in the module to support hot pluggable in application. The performance results of the module are demonstrated. At an operating current of 8mA, an eye diagram at 3Gbit/s is achieved with an optical output of more than 1mW.
Resumo:
In this paper, we present simulation results of an electrooptical variable optical attenuator (VOA) inte-grated in silicon-on-insulator waveguide. The device is functionally based on free carriers absorption toachieve attenuation. Beam propagation method (BPM) and two-dimensional semiconductor device simu-lation tool PISCES-Ⅱ were used to analyze the dc and transient characteristics of the device. The devicehas a response time (including rise time and fall time) less than 200 ns, much faster than the thermoopticand micro-electromechanical systems (MEMSs) based VOAs.
Resumo:
High speed reliable 1.55 mum AlGaInAs multi-quantum well ridge waveguide (RW) DFB laser is developed with a 9GHz -3dB bandwidth. A high speed self aligned constricted mesa 1.55 mum DFB laser is achieved with a 9.1GHz -3dB bandwidth and a more than 20mW output power. A cost effective single RW electroabsorption modulated DFB laser (EMLs) is proposed and successfully fabricated by adopting selective area growth techniques:. a penalty free transmission at 2.5Gbps over 280Km normal G.652 single mode fiber is realized by using this EML as light source. For achieving a better performance EMLs. a gain-coupled DFB laser with etched quantum wells is successfully integrated with a electroabsorption modulator (EAM) for a high single mode yield. the wavelength of a EML is tuned in a 3.2nm range by a integrated thin-film heater for the wavelength routing. a buried heterostructure DFB laser is also successfully integrated with a RW EAM for a lower threshold current. lower EAM parasitic capacitance and higher output power.
Resumo:
Electroabsorption (EA) modulator integrated with partially gain coupling distributed feedback (DFB) lasers have been fabricated and shown high single mode yield and wavelength stability. The small signal bandwidth is about 7.5 GHz. Strained Si1-chiGechi/Si multiple quantum well (MQW) resonant-cavity enhanced (RCE) photodetectors with SiO2/Si distributed Bragg reflector (DBR) as the mirrors have been fabricated and shown a clear narrow bandwidth response. The external quantum efficiency at 1.3 mum is measured to be about 3.5% under reverse bias of 16 V. A novel GaInNAs/GaAs MQW RCE p-i-n photodetector with high reflectance GaAs/ALAs DBR mirrors has also been demonstrated and shown the selectively detecting function with the FWHM of peak response of 12 nm.
Resumo:
In this paper a new half-flash architecture for high speed video ADC is presented. Based on a high speed single-way analog switch circuit, this architecture effectively reduces the number of elements. At the same lime no sacrifice of speed is needed compared with the normal half-flash structure.
Resumo:
High-speed counter-current chromatography (HSCCC) technique in semi-preparative scale has been successfully applied to the separation of bioactive flavonoid compounds, liquiritigenin and isoliquiritigenin in one step from the crude extract of Glycyrrhiza uralensis Risch. The HSCCC was performed using a two-phase solvent system composed of n-hexane-ethyl acetate-methanol-acetonitrile-water (2:2:1:0.6:2, v/v). Yields of liquiritigenin (98.9% purity) and isoliquiritigenin (98.3% purity) obtained were 0.52% and 0.32%. Chemical structures of the purified liquiritigenin and isoliquiritigenin were identified by electrospray ionization-MS (ESI-MS) and NMR analysis. (c) 2005 Published by Elsevier B.V.
Resumo:
With using short capillary column packed with porous and non-porous ODS stationary phases, high speed separation of 6 neutral aromatic compounds within 36 s by capillary electrochromatography (CEC) has been performed. Good reproducibility of the migration times for those solutes in high speed CEC was observed with RSD less than 1%. Both the linear velocity of EOF and the current linearly increases with the applied voltage, which means that the thermal effect by Joule heating was small. However, the capacity factor of solutes was found to decrease with the increase of the applied voltage, which was caused by the fact that about several seconds needed for the increase of voltage from 0 to applied value on a commercial CE instrument made larger contributions to the migration times of the early eluted compounds than those of lately eluted ones during high speed CEC, and voltage effect would increase with the higher applied voltage used. The linear relationship between the logarithm of capacity factor and the number of carbon for homologous compounds was observed, and positive value of slope means that the hydrophobicity of solutes is one of the main contribution factors to retention in high speed CEC packed with ODS stationary phases.
Resumo:
A new mesoporous sphere-like SBA-15 silica was synthesized and evaluated in terms of its suitability as stationary phases for CEC. The unique and attractive properties of the silica particle are its submicrometer particle size of 400 nm and highly ordered cylindrical mesopores with uniform pore size of 12 nm running along the same direction. The bare silica particles with submicrometer size have been successfully employed for the normal-phase electrochromatographic separation of polar compounds with high efficiency (e.g., 210 000 for thiourea), which is matched well with its submicrometer particle size. The Van Deemeter plot showed the hindrance to mass transfer because of the existence of pore structure. The lowest plate height of 2.0 mu m was obtained at the linear velocity of 1.1 mm/s. On the other hand, because of the relatively high linear velocity (e.g., 4.0 mm/s) can be generated, high-speed separation of neutral compounds, anilines, and basic pharmaceuticals in CEC with C-18-modified SBA-15 silica as stationary phases was achieved within 36, 60, and 34 s, respectively.
Resumo:
In this paper we present a lattice Boltzmann model to simulate compressible flows by introducing an attractive force. This scheme has two main advantages: one is to soften sound speed effectively, which greatly raises the Mach number (up to 5); another is its relative simple procedure. Simulations of the March cone and the comparison between theoretical expectations and simulations demonstrate that the scheme is effective in the simulation of compressible flows with high Mach numbers, which would create many new applications.
Resumo:
A finite compact (FC) difference scheme requiring only bi-diagonal matrix inversion is proposed by using the known high-resolution flux. Introducing TVD or ENO limiters in the numerical flux, several high-resolution FC-schemes of hyperbolic conservation law are developed, including the FC-TVD, third-order FC-ENO and fifth-order FC-ENO schemes. Boundary conditions formulated need only one unknown variable for third-order FC-ENO scheme and two unknown variables for fifth-order FC-ENO scheme. Numerical test results of the proposed FC-scheme were compared with traditional TVD, ENO and WENO schemes to demonstrate its high-order accuracy and high-resolution.
Resumo:
活塞的热疲劳性能对柴油发动机的全寿命至关重要。由于能量有限和可控性差等缺点,现有实验系统均不能满意地进行活塞热负荷模拟实验。为此,提出并建立了一套激光诱发活塞热负荷的实验系统。该系统通过对激光束的空间整形,使之投射到活塞表面后诱发的温度场分布满足特定要求。基于PROFIBUS-DP现场总线技术实现了系统集成和实验过程的全反馈控制。针对活塞的典型热负荷条件,即高周热疲劳和热冲击分别进行实验,以模拟正常工作循环和“启动一停车”等热负荷或转速突变工况。通过设置加热一冷却周期或上限下限温度,可以获得相应的热负荷模拟实验效果。研究结果表明,采用经光束整形的激光进行活塞热负荷模拟实验具有周期短、可控性好等优点。