100 resultados para Fast reactors
Resumo:
The atomic motion is coupled by the fast and slow components due to the high frequency vibration of atoms and the low frequency deformation of atomic lattice, respectively. A two-step approximate method was presented to determine the atomic slow motion. The first step is based on the change of the location of the cold potential well bottom and the second step is based on the average of the appropriate slow velocities of the surrounding atoms. The simple tensions of one-dimensional atoms and two-dimensional atoms were performed with the full molecular dynamics simulations. The conjugate gradient method was employed to determine the corresponding location of cold potential well bottom. Results show that our two-step approximate method is appropriate to determine the atomic slow motion under the low strain rate loading. This splitting method may be helpful to develop more efficient molecular modeling methods and simulations pertinent to realistic loading conditions of materials.
Resumo:
Fast plasma sintering deposition of SiC nano-structured coatings was achieved using a specially designed non-transferred dc plasma torch operated at reduced pressure. Employing the Taguchi method, the deposition parameters were optimized and verified. With the optimized combination of deposition parameters, homogeneous SiC coatings were deposited on relatively large area substrates of Φ50 mm and 50×50 mm with a deposition rate as high as 20 μm/min. Ablation test showed that such coatings can be used as oxidation resistance coatings in high temperature oxidizing environment.
Resumo:
一体化反应器由于投资少、占地小、管理运行方便等优点而备受青睐。但现有的一体化反应器大都适用于处理中低浓度废水,耐受负荷普遍偏低。本课题研制出新型高效的厌氧好氧一体化生物反应器,旨在通过反应器结构优化、高效微生物载体研制、配合高效微生物菌剂技术处理中高浓度有机废水,实现高效和低耗,降低设备造价,提高反应器运行稳定性。 首先开展了菌剂对废水的适配试验。采用15种不同的微生物菌剂,以葡萄糖配水、中药提取废水、啤酒废水、氨氮配水为基质,分别测定了微生物菌剂的耗氧速率和厌氧比产甲烷速率,以其为指标比较了各菌剂对废水的适配性。根据结果选择活性高的14#、8#、10#菌剂,在试验室进行了菌剂对废水的连续处理试验,取得良好的处理效果,为菌剂在厌氧好氧一体化生物反应器的小试、中试中的应用奠定了基础。 经小试研究后,又对厌氧好氧一体化生物反应器进行了处理发酵废水的中试研究。试验结果表明,反应器启动快,系统有机负荷2.72 kgCODm-3d-1时整个反应器去除率保持在84.5%~93.19%,在30多天内一次启动成功。冲击负荷试验中,系统总有机负荷最高可达到8.88 kgCODm-3d-1,系统去除率稳定在88.10%~96.88%,说明反应器处理效率高,抗冲击能力强。稳定运行期间,COD去除率可达90%以上,各项指标都能达到国家排放标准。 此外,对反应器配套系统高效菌剂、高分子复合颗粒载体进行了研究。结果显示,菌剂与反应器适配良好,各功能区形成了丰富、高活性的微生物,厌氧区颗粒污泥TS高达83.9 gL-1,VS/TS为56.9%~57.4%,比产甲烷活性为280~350 mLCH4 gvss-1d-1;好氧区固定化微生物TS高达1.921 gL-1,VS/TS为94.02~94.30%。对载体性能的研究表明,此高分子复合颗粒载体密度适中,易于流化,不易流失;粗糙多空,易于挂膜;且无生物毒害作用,稳定安全,是一种优良的生物载体。反应器各功能区对废水的降解过程分析,说明了反应器、菌剂、载体适配良好,在其协同作用下,实现了污染物的高效降解。 The integrated reactors were popular because of their characteristics such as little investment, small occupation of land, convenient of manage and running etc. But the present integrated reactors were mostly applied for treating wastewater of low concentration, the load tolerance was generally on the low side. A new type integrated anaerobic-aerobic bio-reactor was developed, which was conducted to treating organic wastewater of middle or high concentration by optimization of reactor structure, development of efficient microbe carrier and adaptation of high active microbial blends, to achieve high efficiency and low consume, reduce equipment cost, enhance running stabilization of reactor. The adaptability test of microbial blends on different wastewater was carried on firstly. Oxygen consumption rate and anaerobic specific activity of methane producing of 15 different microbial blends were measured separately taking glucose artificial wastewater, Chinese herb extracting wastewater, brewery wastewater and ammonia nitrogen artificial wastewater as substrate, by which the adaptabilities of different microbial blends to wastewater were compared. According to the results high active microbial blends 14#, 8# and 10# were selected and used in the continuous treatment of wastewater in the laboratory and had obtained good effect, which had laid a foundation for application microbial blends to small scale test and pilot test of integrated anaerobic-aerobic bio-reactor. After the small scale test, the pilot test of the integrated anaerobic-aerobic bio-reactor treating fermentation wastewater was carried on. The test results showed fast initiation of the reactor. When system organic load reached 2.72 kgCODm-3d-1the COD removal rate of the reactor was stable between 84.5%~93.19% and it initiated successfully in more than 30 days at a time. In the load shock test the maximum organic load of system could reach to 8.88 kgCODm-3d-1 and the COD removal rate could be stable between 88.10%~96.88% which indicated that the reactor was efficient for treating wastewater and had strong resistance to shock load. At stable running period the COD removal rate of the reactor was over 90% and each index of wastewater could reach to the national discharge standards. In addition, the high active microbial blends and the macromolecule compound granule carrier, the matching system of the reactor was studied. It showed that the microbial blends adapted well to the reactor and abundant and high active microbes were formed in each functional field. The TS of granule sludge in anaerobic field was as high as 83.9 gL-1, the VS/TS was 56.9%~57.4%, the specific activity of methane producing was 280~350 mLCH4 gvss-1d-1. And the TS of immobilized biological granule was as high as 1.921 gL-1, the VS/TS was 94.02%~94.30%. Study on the carrier showed that the self-made macromolecular compound granule carrier was moderate of density, easy of fluidization, unease of running off, rough and porous, easy of films fixation, no bio-toxic, stable and safe, was a kind of superior carrier. Analysis of degradation process in each functional field confirmed the reactor, microbial blends and carriers were in good adaptation and wastewater was decontaminated by their cooperation.
Resumo:
We consider electron capture in fast collisions between a proton and hydrogen in the presence of an intense x-ray laser whose angular frequency omega is close to v(2)/2, where v is the collision velocity. We show that in such a case laser-induced capture becomes possible and that the latter proceeds via both induced photon emission and photon absorption channels and can, in principle, compete with kinematic and radiative electron capture.
Resumo:
The necessity of installing a forward tracking detector stack is discussed for the Hadron Physics LanzhoU Spectrometer(HPLUS). A local tracker is developed to solve the multi-track finding problem. The track candidates are searched iteratively via Hough Transform. The fake tracks are removed by a least square fitting process. With this tracker we have studied the feasibility of pp -> pp + phi(-> K+K-), a typical physical channel proposed on HPLUS. The single track momentum resolution due to the uncertainty of the positioning in FTD is 1.3%. The multiple scattering effect contributes about 20% to the momentum resolution in the FTD coverage. The width and the signal-to-background ratio of the reconstructed phi are 1.51 MeV and 4.36, respectively, taking into account the direct Kaon channel pp -> pp + K+K- as background. The geometry coverage of FTD for phi events is about 85.4%. Based on the current fast simulation and estimation, the geometrical configuration of FTD meets the physical requirement of HPLUS under the current luminosity and multiplicity conditions. The tracker is applicable in the full simulation coming next and is extendable to other tracking component of HPLUS.
Resumo:
For any experiment that uses the beam of an accelerator, monitoring the beam intensity is always art important concern. It is particularly useful if one can continuously measure the beam current without disturbing the beam. We report here on test experiments for an Integrating Current Transformer (ICT) used to measure fast extraction beams from the HIRFL-CSR main ring (CSRm). The laboratory tests and beam intensity measurement results are presented in this paper. The influence of the kicker noise is also analyzed.
Resumo:
The mono- and bimetallic catalytic polymeric hollow-fiber reactors were established with catalytic polymeric cellulose acetate (CA) hollow fibers prepared by supporting the polymer-anchored mono- or bimetallic catalyst in/on the inner wall of the hollow fibers. The selective hydrogenation of cyclopentadiene to cyclopentene was efficiently carried out in the above catalytic polymeric hollow-fiber reactors, especially in the NaBH4 reduced bimetallic PVP-Pd-0.5Co/CA hollow-fiber reactor under mild conditions of 40 degrees C and 0.1 MPa. It was found that there was a remarkable synergic effect of palladium and cobalt reduced by NaBH4 in the bimetallic PVP-Pd-0.5Co/CA hollow-fiber reactor, which results in a 97.5% conversion of cyclopentadiene and a 98.4% selectivity for cyclopentene. (C) 2000 Elsevier Science B.V. All rights reserved.
Resumo:
We propose the exploding-reflector method to simulate a monostatic survey with a single simulation. The exploding reflector, used in seismic modeling, is adapted for ground-penetrating radar (GPR) modeling by using the analogy between acoustic and electromagnetic waves. The method can be used with ray tracing to obtain the location of the interfaces and estimate the properties of the medium on the basis of the traveltimes and reflection amplitudes. In particular, these can provide a better estimation of the conductivity and geometrical details. The modeling methodology is complemented with the use of the plane-wave method. The technique is illustrated with GPR data from an excavated tomb of the nineteenth century.
Resumo:
Subspace learning is the process of finding a proper feature subspace and then projecting high-dimensional data onto the learned low-dimensional subspace. The projection operation requires many floating-point multiplications and additions, which makes the projection process computationally expensive. To tackle this problem, this paper proposes two simple-but-effective fast subspace learning and image projection methods, fast Haar transform (FHT) based principal component analysis and FHT based spectral regression discriminant analysis. The advantages of these two methods result from employing both the FHT for subspace learning and the integral vector for feature extraction. Experimental results on three face databases demonstrated their effectiveness and efficiency.