203 resultados para Eulerþs angles
Resumo:
针对非合作小目标激光测距系统,目标表面的反射特征对激光回波信号有很大的影响。建立测量表面双向反射分布函数(BRDF)的装置,对常用的两种热控材料——白漆涂层和F36多包层,测量了其在1064 nm波长下的双向反射分布函数。得出了白漆涂层镜面反射很小,散射角较大,利于各方向接收回波信号;而F36多包层镜面反射很强,散射角-2°~2°,不利于探测。通过由表面BRDF与由朗伯散射计算得到的最小接收功率的比较,得出了入射角大于45°入射白漆涂层时,回波信号较小;大于2°入射F36多包层时,没有回波信号。
Resumo:
实验研究了激光二极管阵列(LDA)侧向抽运国产Nd∶YAG陶瓷棒的准连续及被动调Q激光输出特性。该陶瓷激光器采用LDA侧面紧密环绕均匀排布的抽运结构,陶瓷棒抽运区域长度为20 mm,其总尺寸为3 mm×35 mm,掺杂原子数分数为~1%。在千赫兹准连续运转条件下,当平-平谐振腔的输出耦合镜透过率为47.3%时,获得最大平均功率23 W的1064 nm激光输出,光束发散角为4.5 mrad,斜率效率达12%。在谐振腔内插入Cr4+∶YAG晶体作为被动调Q开关,成功地实现了陶瓷激光器千赫兹重复频率调Q激光脉冲输出,当Cr4+∶YAG晶体初始透过率为60%时,输出激光脉冲宽度(半峰全宽)可窄至14.5 ns,调Q动静比约为40%。
Resumo:
Graded-index (GRIN) fiber lens arrays are fabricated from commercial GRIN fibers to collimate a high-power laser diode array. The beam divergence angles are reduced to 4.2 and 14.7 mrad in the fast and slow axes, respectively. The influences of smile and fluctuation in fiber length are discussed. Using an aspherical focal lens system, about 74% power can be launched into a fiber with a numerical aperture (NA) of 0.22 and a core diameter of 400 mu m. (c) 2008 Society of Photo-Optical Instrumentation Engineers.
Resumo:
Based on Maxwell's equations, standard boundary conditions are imposed on resultant electric- and magnetic-field vectors at interfaces, and the propagating characteristics of extraordinary waves, such as the forward- and backward-propagating directions of wave vectors, rays and their corresponding refractive indices are determined in a uniaxially birefringent thin film. Furthermore, 2 x 2 characteristic matrices of a birefringent thin film are derived including multiple reflections for the extraordinary wave.
Resumo:
基于非均匀膜理论提出一种存在微缺陷的介质基底的折射率分层模型,将基底依次分为表面层、亚表面层和体材料层,其中表面层和亚面层分别等效为折射率服从统计分布的非均匀膜,将它们分别再次细分为N1和N2个子层,每一子层均视为均匀介质膜.应用光学薄膜特征矩阵法对其进行理论分析,并对单层介质膜的光学性能进行数值计算.研究结果表明:基底的表面和亚表面微缺陷改变了薄膜和基底的等效折射率,导致了准Brewster角和组合反射率与理想情形的偏离.同时这些微缺陷也改变了光在薄膜和基底中的传播特性,因此反射相移和相位差均偏离理想情
Resumo:
A method for the design of an all-dielectric nonpolarizing prism beam splitter utilizing the principle of frustrated total internal reflection is reported. The nonpolarizing condition for a prism beam splitter is discussed, and some single layer design examples are elaborated. The concept can be applied to a wide range of wavelengths and arbitrary transmittance values, and with the help of a computer design program examples of 400-700 nm, T-p = T-p = 0.5 +/- 0.01, with incident angles of 45 degrees and 62 degrees are given. In addition, the sensitivity and application of the design are also discussed. (c) 2006 Optical Society of America.
Resumo:
CO2 laser irradiation experiments on ZnO thin films are reported. The structural, optical, luminescent and vibrational properties of the samples were investigated by X-ray diffraction (XRD), transmittance, photoluminescence (PL) and Raman measurements. XRD results show that the crystalline of the irradiated films was improved. The (002) peaks of irradiated ZnO films shift to. higher 20 angles due to the stress relaxation in the case of laser beam irradiation. From optical transmittance spectra, all films exhibit high transmittance in the visible range, the optical band edge of irradiated films showed a redshift compared with that of as-grown films. Compared with the as-grown films, the photoluminescence emission (in particular the relative intensities of visible emissions) intensities of irradiated samples enhanced. In the Raman scattering spectral both the A I. and E modes exhibited slight Raman blueshift. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
通过分析波矢沿任意方向的单轴晶体的折射率,在光轴位于入射面内时,给出了入射光分别为s光和p光的反射率拟合函数。利用改进的反射率扫描仪,测量了CaCO3晶体的s光和p光反射率随入射角变化情况,由理论拟合获得单轴晶体的两个主折射率,分别为no=1.6559和ne=1.4851。这种方法不需要对样品进行加工,其精度达到0.0001。另外,对于晶体光轴未知的情况,采用改进的布儒斯特技术分别测出三个晶体表面的布儒斯特角,由此可以确定光轴的方向。
Resumo:
设计了在0°和90°方位角下都具有低旁带的鉴别用导模共振滤光片。利用严格的耦合波理论,分析了这种器件在不同入射角、不同光栅槽深和覆盖不同厚度SiO2层情况下的衍射特性。得到了满足鉴别要求的导模共振滤光片结构。在30°入射角情况下,对于TE模式偏振光,设计的滤光片在0°和90°方位角下都有形状对称的反射光谱、低的旁带、两个位置分开的共振峰和适当的半宽度。
Resumo:
With the widespread exposure of people to nicotine through recreational use of tobacco products, research into nicotine has attracted increasing attention. Tobacco smoking is by far the most important cause of lung cancer. As the world's largest producer and consumer of tobacco products, China bears a large proportion of the global burden of smoking-related disease; therefore, information on nicotine publications should be collected to formulate future research policy. In the present study, we investigated nicotine-related research articles published by Chinese authors that were indexed in the Science Citation Index (SCI) from 1991 to 2007. An indicator "citations per publication" (CPP) was used in the study to evaluate the impact of journals, articles, and institutes. The quantity of publications has increased at a quicker pace than the worldwide trend. Article visibility, measured as the frequency of being cited, also increased during the period. However, the overall quality of articles, based on the impact factor of journals publishing those articles, dropped behind the worldwide average level. There has been an increase in international collaboration, mainly with researchers in the USA. The average CPP of international co-authorship articles was higher than that of single country publications. Besides the USA, nicotine research in China will benefit from more collaboration with Taiwan, England, and Germany. Some 110 of 264 articles were published by a single institute, and the top six institutes were compared from various angles. Seventy-two subject categories were covered, and trends (in terms of both quantity and quality) of nicotine research in China were compared with worldwide trends. In addition, analysis of keywords in both nicotine and lung cancer research fields was applied to indicate research interests. Mutual cooperation among multiple disciplines needs further strengthening.
Resumo:
The detection performance regarding stationary acoustic monitoring of Yangtze finless porpoises Neophocaena phocaenoides asiaeorientalis was compared to visual observations. Three stereo acoustic data loggers (A-tag) were placed at different locations near the confluence of Poyang Lake and the Yangtze River, China. The presence and number of porpoises were determined acoustically and visually during each 1-min time bin. On average, porpoises were acoustically detected 81.7 +/- 9.7% of the entire effective observation time, while the presence of animals was confirmed visually 12.7 +/- 11.0% of the entire time. Acoustic monitoring indicated areas of high and low porpoise densities that were consistent with visual observations. The direction of porpoise movement was monitored using stereo beams, which agreed with visual observations at all monitoring locations. Acoustic and visual methods could determine group sizes up to five and ten individuals, respectively. While the acoustic monitoring method had the advantage of high detection probability, it tended to underestimate group size due to the limited resolution of sound source bearing angles. The stationary acoustic monitoring method proved to be a practical and useful alternative to visual observations, especially in areas of low porpoise density for long-term monitoring.
Resumo:
EQUILATERAL-TRIANGLE; MU-M; LASERS; MICROLASERS; MICRODISK Abstract: Mode characteristics for midinfrared microsquare resonators with sloped sidewalls and confined metal layers are investigated by finite-difference time-domain (FDTD) techniques. For a microsquare with a side length of 10 mu m, the mode quality (Q)-factors of 8329, 4772, and 2053 are obtained for TM5,7 mode at wavelength 7.1 mu m by three-dimensional FDTD simulations, as the tilting angles of the side walls are 90 degrees, 88 degrees, and 86 degrees, respectively. Furthermore, microsquare resonators laterally surrounded by SiO2 and metal layers are investigated by the two-dimensional FDTD technique for the metal layers of Au, Ti-Au, Ag-Au, and Ti-Ag-Au, respectively.
Resumo:
A computer program, QtUCP, has been developed based on several well-established algorithms using GCC 4.0 and Qt (R) 4.0 (Open Source Edition) under Debian GNU/Linux 4.0r0. it can determine the unit-cell parameters from an electron diffraction tilt series obtained from both double-tilt and rotation-tilt holders. In this approach, two or more primitive cells of the reciprocal lattice are determined from experimental data, in the meantime, the measurement errors of the tilt angles are checked and minimized. Subsequently, the derived primitive cells are converted into the reduced form and then transformed into the reduced direct primitive cell. Finally all the patterns are indexed and the least-squares refinement is employed to obtain the optimized results of the lattice parameters. Finally, two examples are given to show the application of the program, one is based on the experiment, the other is from the simulation. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
We investigate theoretically the spin-independent tunneling magnetoresistance effect in a graphene monolayer modulated by two parallel ferromagnets deposited on a dielectric layer. For the parallel magnetization configuration, Klein tunneling can be observed in the transmission spectrum but at specific oblique incident angles. For the antiparallel magnetization configuration, the transmission can be blocked by the magneticelectric barrier provided by the ferromagnets. Such a transmission discrepancy results in a tremendous magnetoresistance ratio and can be tuned by the inclusion of an electric barrier.
Resumo:
A 1.55 mu m InGaAsP/InGaAsP multiple-quantum-well electro-absorption modulator (EAM) monolithically integrated with a distributed feedback laser (DFB) diode has been realized based on a novel butt-joint scheme by ultra-low metal-organic vapour phase epitaxy for the first time. The threshold current of 25 mA and an extinction ratio of more than 30 dB are obtained by using the novel structure. The beam divergence angles at the horizontal and vertical directions are as small as 19.3 degrees x 13 degrees, respectively, without a spot-size converter by undercutting the InGaAsP active region. The capacitance of the ridge waveguide device with a deep mesa buried by polyimide was reduced down to 0.30 pF.