103 resultados para Depth, reference


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wavefront coding is a powerful technique that can be used to extend the depth of field of an incoherent imaging system. By adding a suitable phase mask to the aperture plane, the optical transfer function of a conventional imaging system can be made defocus invariant. Since 1995, when a cubic phase mask was first suggested, many kinds of phase masks have been proposed to achieve the goal of depth extension. In this Letter, a phase mask based on sinusoidal function is designed to enrich the family of phase masks. Numerical evaluation demonstrates that the proposed mask is not only less sensitive to focus errors than cubic, exponential, and modified logarithmic masks are, but it also has a smaller point-spread-function shifting effect. (C) 2010 Optical Society of America

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wave-front coding is a well known technique used to extend the depth of field of incoherent imaging system. The core of this technique lies in the design of suitable phase masks, among which the most important one is the cubic phase mask suggested by Dowski and Cathey (1995) [1]. In this paper, we propose a new type called cubic sinusoidal phase mask which is generated by combing the cubic one and another component having the sinusoidal form. Numerical evaluations and real experimental results demonstrate that the composite phase mask is superior to the original cubic phase mask with parameters optimized and provides another choice to achieve the goal of depth extension. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Here we used cytokinesis-block micronucleus assay to measure the biological response along the penetrate depth of ions in water in human lymphocytes exposed to 100 MeV/u incident carbon ions in vitro. Polyethylene shielding was used to change the penetration depth of ions in water. A quantitative biological response curve was generated for micronuclei induction. The results showed a marked increase with the penetrate depth of ions in water in the micronuclei formation, which was consistent with a linearenergy- transfer dependent increase in biological effectiveness. The dose–response relationship for MN information was different at different penetrate depth of ions in water, at the 6 and 11.2 mm penetrate depth of ions in water, the dose–response relationships for the micronucleus frequencies induced by carbon ions irradiation were linear; while it was power function at 17.1 mm penetrate depth.