92 resultados para thyroid peroxidase antibody
Resumo:
A novel third-generation biosensor for hydrogen peroxide (H2O2) was developed by self-assembling gold nanoparticles to hollow porous thiol-functionalized poly(divinylbenzene-co-acrylic acid) (DVB-co-AA) nanospheres. At first, a cleaned gold electrode was immersed in hollow porous thiol-functionalized poly(DVB-co-AA) nanosphere latex to assemble the nanospheres, then gold nanoparticles were chemisorbed onto the thiol groups of the nanospheres. Finally, horseradish peroxidase (HRP) was immobilized on the surface of the gold nanoparticles. The immobilized horseradish peroxidase exhibited direct electrochemical behavior toward the reduction of hydrogen peroxide. The resulting biosensor showed a wide linear range of 1.0 mu M-8.0 mM and a detection limit of 0.5 mu M estimated at a signal-to-noise ratio of 3. Moreover, the studied biosensor exhibited high sensitivity, good reproducibility, and long-term stability.
Resumo:
A novel electrochemical H2O2 biosensor was constructed by embedding horseradish peroxide (HRP) in a 1-butyl-3-methylimidazolium tetrafluoroborate doped DNA network casting on a gold electrode. The HRP entrapped in the composite system displayed good electrocatalytic response to the reduction of H2O2. The composite system could provide both a biocompatible microenvironment for enzymes to keep their good bioactivity and an effective pathway of electron transfer between the redox center of enzymes, H2O2 and the electrode surface. Voltammetric and time-based amperometric techniques were applied to characterize the properties of the biosensor. The effects of pH and potential on the amperometric response to H2O2 were studied. The biosensor can achieve 95% of the steady-state current within 2 s response to H2O2. The detection limit of the biosensor was 3.5 mu M, and linear range was from 0.01 to 7.4 mM. Moreover, the biosensor exhibited good sensitivity and stability. The film can also be readily used as an immobilization matrix to entrap other enzymes to prepare other similar biosensors.
Resumo:
A novel method to fabricate a hydrogen peroxide sensor was developed by immobilizing horseradish peroxidase (HRP) on colloidal An modified ITO conductive glass support. The cleaned glass support was modified with (3-aminopropyl)trimethoxysilane (APTMS) first to yield an interface for the assembly of colloidal An. Then 15 nm colloidal Au particles were chemisorbed onto the amine groups of the APTMS. Finally, HRP was adsorbed onto the surface of the colloidal An. The immobilized HRP displayed excellent electrocatalytical response to the reduction of hydrogen peroxide. The performance and factors influencing the resulted biosensor were studied in detail. The resulted biosensor exhibited fast amperometric response (within 5 s) to H2O2. The detection limit of the biosensor was 8.0 mumol l(-1), and linear range was from 20.0 mumol l(-1) to 8.0 mmol l(-1). Furthermore, the resulted biosensor exhibited high sensitivity, good reproducibility, and long-term stability.
Resumo:
For the first time horseradish peroxidase (HRP) immobilized on the surface of active carbon powder modified at the surface of a glassy carbon electrode has been shown to undergo a direct quasi-reversible electrochemical reaction. Its formal potential, E-o/, is -0.363 V in phosphate buffer solution (pH 6.8) at a scan rate of 100 mV/s and is almost independent of the scan rate in the range of 50-700 mV/s. The dependence of E-o/ on the pH of the buffer solution indicated that the conversion of HRP-Fe(III)/HRP-Fe(II) is a one-electron-transfer reaction process coupled with one-proton-transfer. The experimental results also demonstrated that the immobilized HRP retained its bioelectrocatalytic activity to the reduction of H2O2. Furthermore, the HRP adsorbed oil the surface of the active carbon powder can be stored at 4 degreesC for several months without any loss of the enzyme activity. The method presented for immobilizing HRP can be easily extended to immobilize and obtain the direct electrochemistry of other enzymes.
Resumo:
It is reported for the first time that horseradish peroxidase (HRP) immobilized on the active carbon can undergo a direct quasi-reversible electrochemical reaction. In addition, the immobilized HRP showed the stable bioelectrocatalytic activity for the reduction of H2O2.
Resumo:
We used colloidal An to enhance the amount of antibody immobilized on a gold electrode and ultimately monitored the interaction of antigen-antibody by impedance measurement. Self-assembly of 6 nm (diameter) colloidal An onto the self-assembled monolayers (SAMs) of 4-aminothiophenol modified gold electrode resulted in an easier attachment of antibody. The redox reactions of [Fe(CN)(6)](4-)/[Fe(CN)(6)](3-) on the gold surface were blocked due to the procedures of self-assembly of 4-aminothiophenol and antibody immobilization, which were investigated by cyclic voltammetry and impedance spectroscopy. The interaction of antigen with grafted antibody recognition layers was carried out by soaking the modified electrode into a phosphate buffer at pH 7.4 with various concentrations of antigen at 37 degreesC for 30 min. The antibody recognition layers and their interactions with various concentrations of antigen could be detected by measurements of the impedance change. The results show that this method has good correlation for detection of Hepatitis B virus surface antigen in the range of 0.5-200 mug/l and a detection limit of about 50 ng/l.
Resumo:
Gold nanoparticles were used to enhance the immobilization amount and retain the immunoactivity of recombinant dust mite allergen Der f2 immobilized on a glassy carbon electrode (GCE). The interaction between allergen and antibody was studied by electrochemical impedance spectroscopy (EIS). Self-assembled Au colloid layer (Phi = 16 nm) deposited on (3-mercaptopropyl)trimethoxysilane (MPTS)-modified GCE offered a basis to control the immobilization of allergen Der f2. The impedance measurements were based on the charge transfer kinetics of the [Fe(CN)(6)](3-/4-) redox pair, compared with bare GCE, the immobilization of allergen Der f2 and the allergen-antibody interaction that occurred on the electrode surface altered the interfacial electron transfer resistance and thereby slowed down the charge transfer kinetics by reducing the active area of the electrode or by preventing the redox species in electrolyte solution from approaching the electrode. The interactions of allergen with various concentrations of monoclonal antibody were also monitored through the change of impedance response. The results showed that the electron transfer resistance increased with increasing concentrations of monoclonal antibody.
Resumo:
A novel third-generation hydrogen peroxide (H2O2) biosensor was developed by immobilizing horseradish peroxidase (HRP) on a biocompatible gold electrode modified with a well-ordered, self-assembled DNA film. Cysteamine was first self-assembled on a gold electrode to provide an interface for the assembly of DNA molecules. Then DNA was chemisorbed onto the self-assembled monolayers (SAMs) of cysteamine to form a network by controlling DNA concentration. The DNA-network film obtained provided a biocompatible microenvironment for enzyme molecules, greatly amplified the coverage of HRP molecules on the electrode surface, and most importantly could act as a charge carrier which facilitated the electron transfer between HRP and the electrode. Finally, HRP was adsorbed on the DNA-network film. The process of the biosensor construction was followed by atomic force microscopy (AFM). Voltammetric and time-based amperometric techniques were employed to characterize the properties of the biosensor derived. The enzyme electrode achieved 95% of the steady-state current within 2 s and had a 0.5 mu mol l(-1) detection limit of H2O2. Furthermore, the biosensor showed high sensitivity, good reproducibility, and excellent long-term stability.
Resumo:
A novel mimic TeHA was synthesized by modifying hyaluronic acid (HA) with tellurium, whose function is similar to that of glutathione peroxidase (GPX). The structure of TeHA was characterized by means of infrared spectroscopy and nuclear magnetic resonance spectroscopy, showing that the target Te is located at -CH2OH of the N-acetyl-D-glucosamine of HA. The activity of TeHA is 163.6 U/mu mol according to Wilson's method. In contrast to other mimics, TeHA displays a high activity. Moreover, TeHA can use many hydroperoxides as substrates, such as H2O2, cumenyl hydroperoxide, and tert-butyl hydroperoxide, and cumenyl hydroperoxide is the optimal substrate. A ping-pong mechanism was deduced for the reduction reactions catalyzed by TeHA according to the steady-state kinetic studies.
Resumo:
A novel mimic was synthesized by modifying hyaluronic acid (HA) with tellurium, whose function is similar to that of glutathione peroxidase (GPX). The structure of TeHA was characterized by means of IR and NMR, the target-Te was located at -CH2OH of the N-acetyl-D-glucosamine of HA. The H2O2 reducing activity of TeHA, by glutathione (GSH), was 163.6 U/mu mol according to Wilson's method. In contrast to other mimics, TeHA displayed the highest activity. Moreover, TeHA accepted many hydroperoxides as its substrates, such as H2O2, cumenyl hydroperoxide (CuOOH) and tert-butyl hydroperoxide (t-BuOOH), and CuOOH was the optimal substrate of TeHA. A ping-pong mechanism was observed in the steady-state kinetic studies of the reactions catalyzed by TeHA.
Resumo:
Stable films of didodecyldimethylammonium bromide (DDAB, a synthetic lipid) and horseradish peroxidase (HRP) were made by casting the mixture of the aqueous vesicle of DDAB and HRP onto the glassy carbon (GC) electrode. The direct electron transfer between electrode and HRP immobilized in lipid film has been demonstrated. The lipid films were used to supply a biological environment resembling biomembrane on the surface of the electrode. A pair of redox peaks attributed to the direct redox reaction of HRP were observed in the phosphate buffer solution (pH 5.5). The cathodic peak current increased dramatically while anodic peak decreased by addition of small amount H2O2. The pH effect on amperometric response to H2O2 was studied. The biosensor also exhibited fast response (5 s), good stability and reproducibility.
Resumo:
Protein multilayers composed of avidin and biotin-labeled antibody (bio-Ab) were prepared on gold surface by layer-by-layer assembly technology using the high specific binding constant (K-a: approximate to 10(15) M-1) between avidin and biotin. The assembly process of the multilayer films was monitored by using real-time BIA technique based on surface plasmon resonance (SPR). The multilayer films were also characterized by electrochemical impedance spectroscopy (EIS) and reflection absorption Fourier transform infrared spectroscopy (FTIR). The results indicate that the growth of the multilayer is uniform. From response of SPR for each layer, the stoichiometry S for the interaction between avidin and bio-Ab is calculated to be 0.37 in the multilayer whereas 0.82 in the first layer. The protein mass concentration for each layer was also obtained. The schematic figure for the multilayer assembly was proposed according to the layer mass, concentration and S value. The utility of the mutilayer films for immunosensing has been investigated via their subsequent interaction with hIgG. The binding ability of the multilayer increased for one to three layers of antibody, and then reach saturation after the fourth layer. These layer-by-layer constructed antibody multilayers enhance the binding ability than covalently immobilized monolayer antibody. This technology can be also used for construction of other thin films for immunosensing and biosensor.
Resumo:
It is impossible for surface plasmon resonance to measure directly the binding kinetics between a low-molecular-weight analyte interacting and its immobilized binding partner. Solution competition method was applied to the kinetic study of the interaction between morphine and its antibody. The affinity constant between the antibody of morphine and morphine-BSA immobilized on the sensor chip was also obtained. The result showed that the affinity of polyclonal antibody is stronger than that of monoclonal antibody. And it also indicated that the protein combined with the analyte affected the binding of antibody to antigen.