163 resultados para Iron,Thymine-acetic acid,hydrogen peroxide,alcohol oxidation,olefin halogenation
Resumo:
A novel tris(2,2'-bipyridine)ruthenium(II) (Ru(bpy)3(2+)) cathodic electrochemiluminescence (ECL) was generated at -0.78V at the Pt electrode in acetonitrile (ACN), which suggested that the cathodic ECL differed from conventional cathodic ECL It was found that tripropylamine (TPrA) could enhance this cathodic ECL and the linear range (log-log plot) was 0.2 mu M-0.2 mM. In addition, hydrogen peroxide (H2O2) could inhibit the cathodic ECL and was indirectly detected with the linear range of 27-540 mu M. The RSD (n = 12) of the ECL intensity in the presence of 135 mu M H2O2 was 0.87%. This method was also demonstrated for the fast determination of H2O2 in disinfectant sample and satisfactory results were obtained.
Resumo:
We have demonstrated the design of a new type fluorescent assay based on the inner filter effect (IFE) of metal nanoparticles (NPs), which is conceptually different from the previously reported metal NPs-based fluorescent assays. With a high extinction coefficient and tunable plasmon absorption feature, metal NPs are expected to be capable of functioning as a powerful absorber to tune the emission of the fluorophore in the IFE-based fluorescent assays. In this work, we presented two proof-of-concept examples based on the IFE of Au NPs by choosing MDMO-PPV as a model fluorophore, whose fluorescence could be tuned by the absorbance of Au NPs with a much higher sensitivity than the corresponding absorbance approach.
Resumo:
The phase and morphology variations of titania prepared in ethanol/acetic acid mixture solvents have been systematically investigated. X-ray diffraction results and microscopy observations reveal that pure anatase aggregates consisted of small nanoparticles, pure rutile microspheres comprised of nanofibers, and their mixtures could be obtained by varying ratios of ethanol to acetic acid under solvothermal conditions. The contents of anatase and rutile in the mixed phases also vary with the ratios of ethanol to acetic acid. Field emission scanning electron microscopy and high resolution transmission electron microscopy results show that the two phases are separated from each other in final products and form aggregates with morphologies resembling to their pure phase products obtained under favorable conditions. The as-produced rutile nanofibers, either in pure phase or in mixed phases, tend to grow into hollow microspheres.
Resumo:
Extraction and separation of yttrium from the rare earths in chloride medium using sec-octylphenoxy acetic acid (CA-12), tri-n-butyl phosphate (TBP) as modifier, in kerosene has been investigated. The separation coefficients, beta, were obtained and the extraction selectivity has been enhanced when compared with that of naphthenic acid. The experimental results indicated that CA-12-TBP system could be employed to separate yttrium, from rare earths. Fractional extraction (15 stages for extraction and 10 stages for scrubbing) was studied, the raffinate of the first stage was abundant in purity yttrium of 99.5%, with a yield of > 95%, percentage of yttrium in the mixture rare earths was less than 5% in the loaded organic phase of the 25th stage and loaded capability was about 0.2 mol/L.
Resumo:
A novel electrochemical H2O2 biosensor was constructed by embedding horseradish peroxide (HRP) in a 1-butyl-3-methylimidazolium tetrafluoroborate doped DNA network casting on a gold electrode. The HRP entrapped in the composite system displayed good electrocatalytic response to the reduction of H2O2. The composite system could provide both a biocompatible microenvironment for enzymes to keep their good bioactivity and an effective pathway of electron transfer between the redox center of enzymes, H2O2 and the electrode surface. Voltammetric and time-based amperometric techniques were applied to characterize the properties of the biosensor. The effects of pH and potential on the amperometric response to H2O2 were studied. The biosensor can achieve 95% of the steady-state current within 2 s response to H2O2. The detection limit of the biosensor was 3.5 mu M, and linear range was from 0.01 to 7.4 mM. Moreover, the biosensor exhibited good sensitivity and stability. The film can also be readily used as an immobilization matrix to entrap other enzymes to prepare other similar biosensors.
Resumo:
A novel method to fabricate a hydrogen peroxide sensor was developed by immobilizing horseradish peroxidase (HRP) on colloidal An modified ITO conductive glass support. The cleaned glass support was modified with (3-aminopropyl)trimethoxysilane (APTMS) first to yield an interface for the assembly of colloidal An. Then 15 nm colloidal Au particles were chemisorbed onto the amine groups of the APTMS. Finally, HRP was adsorbed onto the surface of the colloidal An. The immobilized HRP displayed excellent electrocatalytical response to the reduction of hydrogen peroxide. The performance and factors influencing the resulted biosensor were studied in detail. The resulted biosensor exhibited fast amperometric response (within 5 s) to H2O2. The detection limit of the biosensor was 8.0 mumol l(-1), and linear range was from 20.0 mumol l(-1) to 8.0 mmol l(-1). Furthermore, the resulted biosensor exhibited high sensitivity, good reproducibility, and long-term stability.
Resumo:
A novel third-generation hydrogen peroxide (H2O2) biosensor was developed by immobilizing horseradish peroxidase (HRP) on a biocompatible gold electrode modified with a well-ordered, self-assembled DNA film. Cysteamine was first self-assembled on a gold electrode to provide an interface for the assembly of DNA molecules. Then DNA was chemisorbed onto the self-assembled monolayers (SAMs) of cysteamine to form a network by controlling DNA concentration. The DNA-network film obtained provided a biocompatible microenvironment for enzyme molecules, greatly amplified the coverage of HRP molecules on the electrode surface, and most importantly could act as a charge carrier which facilitated the electron transfer between HRP and the electrode. Finally, HRP was adsorbed on the DNA-network film. The process of the biosensor construction was followed by atomic force microscopy (AFM). Voltammetric and time-based amperometric techniques were employed to characterize the properties of the biosensor derived. The enzyme electrode achieved 95% of the steady-state current within 2 s and had a 0.5 mu mol l(-1) detection limit of H2O2. Furthermore, the biosensor showed high sensitivity, good reproducibility, and excellent long-term stability.
Resumo:
Synergistic extraction of trivalent rare earths (RE=Sc, Y, La, Gd, Yb) from hydrochloride medium using mixture of bis(2,4,4-trimethylpentyl)phosphinic acid (HL, Cyanex272) and Sec-nonylphenoxy acetic acid (HA, CA-100) in n-heptane has been studied. The synergistic enhancement coefficients were observed for La (1.30), Gd (1.97), Y (3.59), Yb (8.21) and Sc (14.41). The results indicated yttrium was extracted into n-heptane as YH(5)A(4)L(4) mixed species instead of Y(HL2)(3), Y(OH)(2)A(HA)(3) which were extracted by Cyanex272 and CA-100, respectively. A cation exchange mechanism was proposed and further clarified by IR spectra. The equilibrium constants, formation constants and thermodynamic functions such as Delta G, Delta H and Delta S were determined. The Cyanex272 + CA-100 system not only enhanced the extraction efficiency of RE but also improved the selectivities significantly. The mutual separation factors of these ions suggested the mixture system would be of practical value in extraction and separation of rare earths.
Resumo:
Stable films of didodecyldimethylammonium bromide (DDAB, a synthetic lipid) and horseradish peroxidase (HRP) were made by casting the mixture of the aqueous vesicle of DDAB and HRP onto the glassy carbon (GC) electrode. The direct electron transfer between electrode and HRP immobilized in lipid film has been demonstrated. The lipid films were used to supply a biological environment resembling biomembrane on the surface of the electrode. A pair of redox peaks attributed to the direct redox reaction of HRP were observed in the phosphate buffer solution (pH 5.5). The cathodic peak current increased dramatically while anodic peak decreased by addition of small amount H2O2. The pH effect on amperometric response to H2O2 was studied. The biosensor also exhibited fast response (5 s), good stability and reproducibility.
Resumo:
A highly catalytic activity microperoxidase-11 (MP-11) biosensor for H2O2 was developed to immobilizing the heme peptide in didodecyldimethylammonium bromide (DDAB) lipid membrane. The enzyme electrode thus obtained responded to H2O2 without electron mediator or promoter, at a potential of +0.10 V versus Ag \ AgCl. A linear calibration curve is obtained over the range from 2.0 x 10(-5) to 2.4 x 10(-3) M. The biosensor responds to hydrogen peroxide in 15 s and has a detection limit of 8 x 10(-7) M (S/N = 3) Providing a natural environment with lipid membrane for protein immobilization and maintenance of protein functions is a suitable option for the design of biosensors.
Resumo:
The interfacial behavior of sec-nonylphenoxy acetic acid (CA-100) at various diluents/(H, Na)Cl interfaces was examined using the Du Nouy ring method. Different adsorption isotherms such as the Gibbs and Szyszkowski were in good agreement with the experimental data. The values of interfacial excess at saturated interface increase in the following order: n-heptane > kerosene > cyclohexane > CCl4 > toluene > benzene > chloroform. The effects of temperature, acidity, and ionic strength of the aqueous phase on the interfacial activity of CA- 100 were also examined. The interfacial-activity data were used to discuss the mechanism and kinetics of yttrium (Y) extraction.
Resumo:
Separation of scandium(III), yttrium(III) and lanthanum(III) was performed by high-performance centrifugal partition chromatography (HPCPC) employing the stationary phase of S-octyl phenyloxy acetic acid (CA-12). The liquid-liquid extraction behavior of CA-12 for Sc(III), Y(III) and La(III), the acidity of aqueous phase, and the operation conditions of HPCPC were examined. The retention volume (V-R) increased with the order of Y(III), La(III) and Sc(III) accompanied with the elution of the mobile phase in different pH, which is lowered from 4.6 to 2.1.