82 resultados para Brand Image


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider the effect of image forces, arising due to a difference in dielectric permeabilities of the well layer and barrier layers, on the energy spectrum of an electron confined in a rectangular potential well under a magnetic field. Depending on the value and the sign of the dielectric mismatch, image forces can localize electrons near the interfaces of the well or in well centre and change the direct intersubband gaps into indirect ones. These effects can be controlled by variation of the magnetic field, offering possibilities for exact tuning of electronic devices.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hybrid opto-digital joint transform correlator (HODJTC) is effective for image motion measurement, but it is different from the traditional joint transform correlator because it only has one optical transform and the joint power spectrum is directly input into a digital processing unit to compute the image shift. The local cross-correlation image can be directly obtained by adopting a local Fourier transform operator. After the pixel-level location of cross-correlation peak is initially obtained, the up-sampling technique is introduced to relocate the peak in even higher accuracy. With signal-to-noise ratio >= 20 dB, up-sampling factor k >= 10 and the maximum image shift <= 60 pixels, the root-mean-square error of motion measurement accuracy can be controlled below 0.05 pixels.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to realize the steady-state droplet evaporation, image feedback control system is designed based on DSP. The system has three main functions: to capture and store droplet images during the experiment; to calculate droplet geometrical and physical parameters such as volume, surface area, surface tension and evaporation velocity at a high-precision level; to keep the droplet volume constant. The DSP can drive an injection controller with the PID control to inject liquid so as to keep the droplet volume constant. The evaporation velocity of droplet can be calculated by measuring the injected volume during the evaporation. The structure of hardware and software of the control system, key processing methods such as contour fitting and experimental results are described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A full-ring PET insert device should be able to enhance the image resolution of existing small-animal PET scanners. Methods: The device consists of 18 high-resolution PET detectors in a cylindric enclosure. Each detector contains a cerium-doped lutetium oxyorthosilicate array (12 x 12 crystals, 0.72 x 1.51 x 3.75 mm each) coupled to a position-sensitive photomultiplier tube via an optical fiber bundle made of 8 x 16 square multiclad fibers. Signals from the insert detectors are connected to the scanner through the electronics of the disabled first ring of detectors, which permits coincidence detection between the 2 systems. Energy resolution of a detector was measured using a Ge-68 point source, and a calibrated 68Ge point source stepped across the axial field of view (FOV) provided the sensitivity profile of the system. A Na-22 point source imaged at different offsets from the center characterized the in-plane resolution of the insert system. Imaging was then performed with a Derenzo phantom filled with 19.5 MBq of F-18-fluoride and imaged for 2 h; a 24.3-g mouse injected with 129.5 MBq of F-18-fluoride and imaged in 5 bed positions at 3.5 h after injection; and a 22.8-g mouse injected with 14.3 MBq of F-18-FDG and imaged for 2 h with electrocardiogram gating. Results: The energy resolution of a typical detector module at 511 keV is 19.0% +/- 3.1 %. The peak sensitivity of the system is approximately 2.67%. The image resolution of the system ranges from 1.0- to 1.8-mm full width at half maximum near the center of the FOV, depending on the type of coincidence events used for image reconstruction. Derenzo phantom and mouse bone images showed significant improvement in transaxial image resolution using the insert device. Mouse heart images demonstrated the gated imaging capability of the device. Conclusion: We have built a prototype full-ring insert device for a small-animal PET scanner to provide higher-resolution PET images within a reduced imaging FOV. Development of additional correction techniques are needed to achieve quantitative imaging with such an insert.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

利用反应显微谱仪对70keV He2+-He转移电离过程中的出射电子进行了成像,研究了出射电子的空间速度分布特征.结果表明:电子主要集中在散射平面内;在散射平面内,电子速度分布介于零与入射离子速度Vp之间(即前向出射)且在散射离子和靶核核间轴处有一极小值,呈现出典型的双峰结构.出射电子的上述分布特征可由出射电子波函数σ振幅和π振幅的干涉进行定性解释,σ振幅和π振幅对出射电子波函数的贡献与碰撞参数相关.在小碰撞参数下,π振幅的贡献更加明显;而在大碰撞参数下,σ振幅的贡献更加显著.