127 resultados para 1995_01200200 TM-34 4301602
Resumo:
The National Science Foundation of China(Grant No. 60578044).
Resumo:
A normal-incidence nonpolarizing guided-mode resonance filter is designed. There are two waveguide layers and one grating layer in the filter. By adjusting the distance between the two waveguide layers, the same resonance wavelength for both TE and TM polarization can be achieved. An antireflection design method is also used to decrease the sideband reflection of the filter. The results show that the filter has high reflection, more than 99.9% at 500 nm, and the FW-HMs of TE- and TM-polarized light are 2.16 and 0.15 nm, respectively. (C) 2009 Optical Society of America
Resumo:
大范围、实时、准确地监测典型草原地区草场退化或健康状况对于草原生态系统的保育、农牧业的可持续性发展具有非常重要的意义。比起传统的群落学研究方法,遥感技术对于监测大尺度的植被状况具有无可争议的优越性,并且已经被广泛引入监测植被覆盖变化的研究中。本项研究系统地分析、综述了过去用非遥感手段对放牧和草场退化的关注和研究,介绍了遥感技术应用于植被研究的理论基础、主要途径(植被指数)、有关领域的研究进展。特别是本文提出草场退化状况或整体健康状况可以由基干相互独立的层面表示,而过去监测植被变化主要依赖的NDVI等植被指数只能监测草原植被的个别层面(总量层)。 本文以草场放牧退化比较典型的内蒙古锡林河流域为研究对象,在进行了大量的野外样方调查的基础上,提出一种结合群落样方调查和遥感技术的监测草场健康状况的新方法。本文引入主成份分析方法(PCA),从包含12个反映群落各方面信息的变量中提取出3个有特定生态学意义的主成份,并进一步对其进行分析组合,得出一个能比较敏感、全面反映群落健康状况的新指标-草场健康指数(GHI)。 从6波段的植被光谱反射数据中比较理想地提取出2个主成份:可见光因子和红外光因子。表征群落总量、放牧退化的主成份和GHI与样方光谱反射值有相当的相关性,由此得到GHI与可光、红外光因子的回归模型。 应用此模型到卫星遥感数据(TM),得到GHI影像,并与同一数据的NDVI影像作对比研究,发现GHI在反映放牧等人为干扰对草原植被的影响效应方面比NDVI有明显的优点。此外,GHI影像对植被分布格局,特别是斑块结构有更好的显示效果。应用GHI到历史TM数据,对所研究地域的植被覆盖变化、农牧业的变迁模式等进行了定性研究。研究还发现有较长放牧史的过度放牧区的植被类型没有沿牧压梯度的规律性分布,而是呈随机斑块分布模式。
Resumo:
AIM: To investigate the interaction between human CCR5 receptors (CCR5) and HIV-1 envelope glycoprotein gp120 (HIV-1 gp120) and HIV-1 receptor CD4 antigens (CD4). METHODS: The structurally con served regions (SCR) of human CCR5 was built by the SYBYL/Biopolymer module using the corresponding transmembrane (TM) domain of bacteriorhodopsin (bR) as the template. The coordinates for amino-ter minal residue sequence, and carboxyl-terminal residue sequence, extracellular and cytoplasmic loops were generated using LOOP SEARCH algorithm. Subsequently the structural model was merged into the complex with HIV-1 gp120 and CD4. RESULTS: Human CCR5 interacted with both an HIV-1 gp120 and CD4. The N-terminal residues (especially Met1 and Gln4) of human CCR5, contacted with CD4 residues, mainly 7Nith one span (56 - 59) of CD4 in electrostatic interaction and hydrogen-bonds. The binding sites of human CCR5 were buried in a hydrophobic center surrounded by a highly basic periphery. On the other hand, direct interatomic contacts were made between ? CCR5 residues and 6 gp120 amino-acid residues, which included van der Waals contacts, hydrophobic interaction, and hydrogen bonds. CONCLUSION: The interaction model should be helpful for rational design of novel anti-HIV drugs.
Resumo:
Submitted by zhangdi (zhangdi@red.semi.ac.cn) on 2009-06-04T08:36:34Z No. of bitstreams: 1 dspace.cfg: 33388 bytes, checksum: ac9630d3fdb36a155287a049e8b34eb7 (MD5)
Resumo:
Mode characteristics of three-dimensional (3-D) microsquare resonators are investigated by finite-difference time-domain (FDTD) simulation for the transverse electric (TE)-like and the transverse magnetic (TM)-like modes. For a pillar microsquare with a side length of 2 pin in air, we have Q-factors about 5 X. 103 for TM-like modes at the wavelength of 1550 run, which are one order larger than those of TE-like modes, as vertical refractive index distribution is 3.17/3.4/3.17 and the cororresponding center layer thickness is 0.2 mu m. The mode field patterns show that TM-like modes have much weaker vertical radiation coupling loss than TE-like modes. TM-like modes can have high Q-factors in a microsquare with weak vertical field confinement.
Resumo:
Three known standards, including at least one transmission standard, are normally required for the full two-port calibration of test fixtures. Based on the triple-through method, a new general-purpose calibration procedure using only one known reflection standard is proposed in this paper. The experimental results show that our method call provide a simple and accurate approach to fall two-port calibration of the asymmetric test fixtures. (c) 2005 Wiley Periodicals, Inc.
Resumo:
We present a generation condition for realizing high-Q TM whispering-gallery modes (WGMs) in semiconductor microcylinders. For microcylinders with symmetry or weak asymmetry vertical waveguiding, we show that TM WGMs can have a high Q factor, with the magnitude of 10(4) at the radius of the microcylinder of 1 mu m, by three-dimensional numerical simulation. The Q factor of TE WGMs is much less than that of TM WGMs in the semiconductor microcylinders due to a vertical radiation loss caused by mode coupling with the vertical propagating mode. The results open up a possible application of TM WGMs in semiconductor microcylinders for efficient current injection microlasers and single photon sources.
Resumo:
A short wavelength (lambda similar or equal to 3.5 mu m) strain-compensated InxGa(1-x)As/InyAl(1-y)As quantum cascade laser is reported. Quasi-continuous wave operation of this device at 34 degrees C with an output power of 11.4mW persisted for more than 30 minutes without obvious degradation. A very low threshold current density of 1.2KA/cm(2) at this temperature was observed.
Resumo:
We have investigated the mode characteristics for three-dimensional (3D) semiconductor microresonators by finite-difference time-domain (FDTD) technique. The results show that the quality-factors (Q-factors) of TM-like modes are much larger than those of TE-like modes as the vertical waveguidng formed by semiconductor materials.