56 resultados para therapeutic vaccination, adoptive immunotherapy, mCMV, murine cytomegalovirus, dense bodies


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on the density functional theory, we systematically study the optical and electronic properties of the insulating dense sodium phase (Na-hp4) reported recently (Ma et al., 2009). The structure is found optically anisotropic. Through Bader analysis, we conclude that ionicity exists in the structure and becomes stronger with increasing pressure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Up to now, clinical trials of heavy-ion radiotherapy for superficially placed tumors have been carried out for six times and over 60 selected patients have been treated with 80—100 MeV/u carbon ions supplied by the Heavy Ion Research Facility in Lanzhou (HIRFL) at the Institute of Modern Physics, Chinese Academy of Sciences since November, 2006. A passive irradiation system and a dose optimization method for radiotherapy with carbon-ion beams have been developed. Experimental verification of longitudinally ...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We discuss the onset of superfluidity in neutron stars, where the model of nuclear matter is realized in a high-density and asymmetry state. In particular, we present the study of the effects of microscopic three-body forces on the proton pairing in the 1S0 channel and neutron pairing in 3PF1 channel for β-stable neutron star matter. It is found that the main effects of three-body forces are to shrink the domain of existence of the 1S0 below the threshold of the direct URCA process and to stretch the density range of the 3PF1 pairing in a broad domain so to cover most part of the neutron-star core.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We introduce and summary our research progress on the effective masses of K meson in dense nuclear matter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To estimate the biological risks from space radiation encountered by cosmonauts in outer space, the effects from whole-body exposure to carbon ions or X-rays irradiations at 0, 0.39, 0.55 and 1 Gy at a dose rate of 0.2 Gy/min were investigated in BALB/c mice. The relative thymus and spleen weights were measured at 24 h after exposure, and the cell cycle distribution and percentage of apoptosis of thymocytes and spleen and peripheral blood lymphocytes were determined by flow cytometry. The data showed that exposure to carbon ions delayed cell progression of peripheral blood lymphocytes in S-phase, and delayed thymocytes and spleen lymphocytes in G(0)/G(1)-phase. Apoptosis of thymocytes and peripheral blood lymphocytes induced by carbon ions increased more rapidly with dose than was the case for X-rays. There were some differences between the relative weight loss of the thymus and the spleen with increasing dose of either carbon ions or X-rays. The results obtained provide evidence of dose- and organ-specific differences induced by carbon ions compared to X-rays, with increased apoptosis in peripheral blood lymphocytes and thymocytes, but not spleen lymphocytes. Our data may suggest that further work would be of interest to estimate risk of changes in immune function during particle radiation exposures in space travel. (c) 2007 COSPAR

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For the first time the physical properties of therapeutic carbon-ion beam supplied by, the shallow-seated tumor therapy terminal at the Heavy Ion Research Facility in Lanzhou (HIRFL) are measured. For a 80.55MeV/u C-12 ion beam delivered to the therapy terminal, the homogeneity of irradiation fields is 73.48%, when the beam intensity varied in the range of 0.001-0.1nA (i.e. 1 X 10(6) - 1 X 10(8) particles per second). The stability of the beam intensity within a few minutes is estimated to be 80.87%. The depth-dose distribution of the beam at the isocenter of the therapy facility is measured, and the position of the high-dose Bragg peak is found to be located at the water-equivalent depth of 13.866mm. Based on the relationship between beam energy and Bragg peak position, the corresponding beam energy at the isocenter of the therapy terminal is evaluated to be 71.71MeV/u for the original 80.55MeV/u C-12 ion beam, which consisted basically with calculation. The readout of the previously-used air-free ionization chamber regarding absorbed dose is calibrated as well in this experiment. The results indicate that the performance of the therapy facility should be optimized further to meet the requirements of clinical trial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The nuclear symmetry energy E-sym(rho) is the most uncertain part of the Equation of State (EOS) of dense neutron-rich nuclear matter. In this talk, we discuss the underlying physics responsible for the uncertain E-sym(rho) especially at supra-saturation densities, the circumstantial evidence for a super-soft E-sym(rho) from analyzing pi(-)/pi(+) ratio in relativistic heavy-ion collisions and its impacts on astrophysics and cosmology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The oxidative dehydrogenation of ethane to ethylene (ODHE) has been studied in a catalytic membrane reactor (CMR) using a dense mixed ionic oxygen and electronic conducting perovskite membrane Ba0.5Sr0.5Co0.8Fe0.2O3-&. At 1080K, an ethylene yield of 66% was obtained with the bare membrane. After Pd cluster deposition, the ethylene yield reached 76% at 1050K. Ni cluster deposition led to a decrease of ethane conversion compared to the bare membrane without changing ethylene selectivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In our previous work, it was shown that LiLaNiO/gamma-Al2O3 was an excellent catalyst for partial oxidation of heptane to syngas in a fixed-bed reactor at high temperature and the selectivity of CO was about 93%. However, pure oxygen was used as the oxidant. We have developed a dense oxygen permeation membrane Ba0.5Sr0.5Co0.8Fe0.2O3 that can supply pure oxygen for the reaction. In this work, the membrane was combined with the catalyst LiLaNiO/gamma-Al2O3 in one rector for the partial oxidation of heptane that is typical component of gasoline. A good performance of the membrane reactor has been obtained, with 100% n-heptane conversion and >94% hydrogen selectivity at the optimized reaction conditions. (C) 2004 Elsevier B.V. All rights reserved.