234 resultados para laser ion source
Resumo:
A windowed very-small-aperture laser 9VSAL0 source for use in high-resolution near field optical data storage is fabricated. The windowed regions are introduced to avoid shorting the pn junction with metal coating and suppress the COD effect. It facilitates producing VSAL by simplified technology and improves the laser performance. A VSAL with 400nm small sperture is demonstrated by focused ion beam (FIB0 and the output power is 0.3mW at 31mA.
Resumo:
In this report, we start from Lagrange equation and analyze theoretically the electron dynamics in electromagnetic field. By solving the relativistic government equations of electron, the trajectories of an electron in plane laser pulse, focused laser pulse have been given for different initial conditions. The electron trajectory is determined by its initial momentum, the amplitude, spot size and polarization of the laser pulse. The optimum initial momentum of the electron for LSS (laser synchrotron source) is obtained. Linear polarized laser is more advantaged than circular polarized laser for generating harmonic radiation.
Resumo:
多层介质反射镜在非正入射的时候,两个不同的偏振态之间会产生不同的相移。利用矩阵法,根据菲涅耳公式和电磁场边界条件,推导出p,s波的相移。通过优化设计.入射角为54°,在1285~1345nm之间p,s波获得了270°±1°的相移,同时也使反射率在99.5%以上。用离子束溅射技术制备相位延迟膜,用分光光度计测试了光谱特性和用椭偏仪测试了相位特性,在相应波段获得了262.4°±1.8°的相移,同时也使反射率在99.6%以上。误差的主要来源是离子源工作特性会产生不均匀的过渡层和最外层会吸收一些水气、灰尘等也产生
Resumo:
Titanium and zirconia are bioinert materials lacking bioactivity. In this work, surface modification of the two typical biomaterials is conducted by Mg-ion-implantation using a MEVVA ion source in an attempt to increase their bioactivity. Mg ions were implanted into zirconia and titanium with fluences ranging from 1 x 10(17) to 3 x 10(17) ions/cm(2) at 40 keV. The Mg-implanted samples, as well as control (unimplanted) samples, were immersed in SBF for 7 days and then removed to identify the presence of calcium and phosphate (Ca-P) coatings and to characterize their morphology and structure by SEM, XRD, and FT-IR. SEM observations confirm that globular aggregates are formed on the surfaces of the Mg-implanted zirconia and titanium while no precipitates are observed on the control samples. XRD and FT-IR analyses reveal that the deposits are carbonated hydroxyapatite (HAp). Our experimental results demonstrate that Mg-implantation improves the bioactivity of zirconia and titanium. Further, it is found that the degree of bioactivity is adjustable by the ion dose. Mechanisms are proposed to interpret the improvement of bioactivity as a result of Mg implantation and the difference in bioactivity between zirconia and titanium. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
A direct ion beam deposition system designed for heteroepitaxy at a low substrate temperature and for the growth of metastable compounds has been constructed and tested. The system consists of two mass-resolved low-energy ion beams which merge at the target with an incident energy range 50-25 000 eV. Each ion beam uses a Freeman ion source for ion production and a magnetic sector for mass filtering. While a magnetic quadrupole lens is used in one beam for ion optics, an electrostatic quadrupole lens focuses the other beam. Both focusing approaches provide a current density more than 100-mu-A/cm2, although the magnetic quadrupole gives a better performance for ion energies below 200 eV. The typical current of each beam reaches more than 0.3 mA at 100 eV, with a ribbon beam of about 0.3-0.5 x 2 cm2. The target is housed in an ultrahigh vacuum chamber with a base pressure of 1 x 10(-7) Pa and a typical pressure of 5 x 10(-6) Pa when a noncondensable beam like argon is brought into the chamber. During deposition, the target can be heated to 800-degrees-C and scanned mechanically with an electronic scanning control unit. The dual beam system has been used to grow GaN using a Ga+ and a N+ beam, and to study the oxygen and hydrogen ion beam bombardment effects during carbon ion beam deposition. The results showed that the simultaneous arrival of two beams at the target is particularly useful in compound formation and in elucidation of growth mechanisms.
Resumo:
Uranium ion beams were produced from electron cyclotron resonance (ECR) ion sources by sputtering method this year at the Institute of Modern Physics. At first, we chose the Lanzhou ECR No. 3 ion source to implement the production experiment of U ion beams. Finally, 11 e mu A of U28+, 5 e mu A of U32+, and 1.5 e mu A of U35+ were obtained. A U26+ ion beam produced by the LECR2 ion source was accelerated successfully by the cyclotron. This means that the Heavy Ion Research Facility in Lanzhou (HIRFL) has accomplished the acceleration of the ion beam of the heaviest element according to the designed parameters. The Lanzhou ECR ion source No. 2 (LECR2), which was built in 1997, has served the HIRFL for eight years and needed to be upgraded to provide more intense high charge state ion beams for HIRFL cooling storage ring. We started the upgrading project of LECR2 last year, and the modified design just has been finished. (c) 2006 American Institute of Physics.
Resumo:
The high charge state all permanent Electron Cyclotron Resonance Ion Source (ECRIS) LAPECR2 (Lanzhou All Permanent magnet ECR ion source No.2) has been successfully put on the 320kV HV platform at IMP and also has been connected with the successive LEBT system. This source is the largest and heaviest all permanent magnet ECRIS in the world. The maximum mirror field is 1.28T (without iron plug) and the effective plasma chamber volume is as large as circle divide 67mm x 255mm. It was designed to be operated at 14.5GHz and aimed to produce medium charge state and high charge state gaseous and also metallic ion beams. The source has already successfully delivered some intense gaseous ion beams to successive experimental terminals. This paper will give a brief overview of the basic features of this permanent magnet ECRIS. Then commissioning results of this source on the platform, the design of the extraction system together with the successive LEBT system will be presented.
Resumo:
Since 1998, many experiments for metallic ion production have been done on LECR2 (Lanzhou ECR ion source NO.2), LECR3 (Lanzhou ECR ion source NO.3) and SECRAL (Superconductiong ECR ion source Advanced design in Lanzhou) at Institute of Modern Physics. The very heavy metallic ion beams such as those of uranium were also produced by the plasma sputtering method, and supplied for HIRFL (Heavy Ion Research Facility in Lanzhou) accelerators successfully. During the test, 11.5e mu AU(28+), 9e mu AU(24+) were obtained. Some ion beams of the metal having lower melting temperature such as Ni and Mg ion beams were produced by oven method on LECR3 too. The consumption rate was controlled to be lower for Mg-26 ion beams production, and the minimum consumption was about 0.3mg per hour. In this paper, the main experimental results are given. Some discussions are made for some experimental phenomena and results, and some conclusions are drawn.
Resumo:
The emittance of an extracted ion beam can be estimated to first order by a series of three linear independent profile measurements. This estimation is restricted to the evaluation of an upper limit of the emittance value for a homogeneous, nonfilamented beam. The beam is assumed to be round, respectively elliptical, without any structure of the intensity distribution, no space charge has been assumed for the drifting beam, and the optics is assumed to be linear. Instead of using three different drift sections, a linear focusing element with three different focusing strengths can be used. Plotting the beam radius as function of focusing strength, three independent solutions can be used to calculate the Twiss parameters alpha, beta, and gamma and furthermore the emittance epsilon. Here we describe the measurements which have been performed with the SECRAL ion source at Institute of Modern Physics Lanzhou.
Resumo:
Superconducting electron cyclotron resonance ion source with advanced design in Lanzhou (SECRAL) is an all-superconducting-magnet electron cyclotron resonance ion source (ECRIS) for the production of intense highly charged ion beams to meet the requirements of the Heavy Ion Research Facility in Lanzhou (HIRFL). To further enhance the performance of SECRAL, an aluminum chamber has been installed inside a 1.5 mm thick Ta liner used for the reduction of x-ray irradiation at the high voltage insulator. With double-frequency (18+14.5 GHz) heating and at maximum total microwave power of 2.0 kW, SECRAL has successfully produced quite a few very highly charged Xe ion beams, such as 10 e mu A of Xe37+, 1 e mu A of Xe43+, and 0.16 e mu A of Ne-like Xe44+. To further explore the capability of the SECRAL in the production of highly charged heavy metal ion beams, a first test run on bismuth has been carried out recently. The main goal is to produce an intense Bi31+ beam for HIRFL accelerator and to have a feel how well the SECRAL can do in the production of very highly charged Bi beams. During the test, though at microwave power less than 3 kW, more than 150 e mu A of Bi31+, 22 e mu A of Bi41+, and 1.5 e mu A of Bi50+ have been produced. All of these results have again demonstrated the great capability of the SECRAL source. This article will present the detailed results and brief discussions to the production of highly charged ion beams with SECRAL.
Resumo:
During the past. decades, large-scale national neutron sources have been developed in Asia, Europe, and North America. Complementing such efforts, compact hadron beam complexes and neutron sources intended to serve primarily universities and industrial institutes have been proposed, and some have recently been established. Responding to the demand in China for pulsed neutron/proton-beam platforms that are dedicated to fundamental and applied research for users in multiple disciplines from materials characterization to hadron therapy and radiography to accelerator-driven sub-critical reactor systems (ADS) for nuclear waste transmutation, we have initiated the construction of a compact, yet expandable, accelerator complex-the Compact Pulsed Hadron Source (CPHS). It consists of an accelerator front-end (a high-intensity ion source, a 3-MeV radio-frequency quadrupole linac (RFQ), and a 13-MeV drift-tube linac (DTL)), a neutron target station (a beryllium target with solid methane and room-temperature water moderators/reflector), and experimental stations for neutron imaging/radiography, small-angle scattering, and proton irradiation. In the future, the CPHS may also serve as an injector to a ring for proton therapy and radiography or as the front end to an ADS test facility. In this paper, we describe the design of the CPHS technical systems and its intended operation.
Resumo:
本文论述了高电荷态ECR离子源的最新进展和原理;介绍了10GHz ECR2高电荷态离子源的设计特点和调试结果。在此离子源上发现了ECR离子源的新工作模式和新约束场形,新工作模式不同于传统工作模式的地方是在ECR离子源引出端注入低能电子;推动等离子体电极到更靠近高电荷态离子的约束区域;移动等磁压面使ECR等离子体向引出区域移动。新工作模式使ECR离子束流强度大为提高,得到Ar8+离子430μA、Ar9+离子320μA、O6+离子450μA;微波利用系数增加;工作气体气耗量减少。本文对新工作模式原理进行了详细的分析和讨论,得出高电荷态ECR离子源的一个重要结论,即引出端低能电子的注入比在注入端注入更有效。 本文还进行了将连续激光蒸发技术应用到ECR离子源中的研究。在10GHz ECR2离子源中使用50W连续CO2激光蒸发金属铝,得到Al6+离子约50μA。在此基础上根据ECR离子源新工作模式原理,提出了在ECR离子源引出端使用热阴极电子枪的设想,并阐述了其工作原理和设计。在激光离子源实验中发现强激光产生的等离子体具有独特的性质,如方向性、脉冲性和漂移性。在实验中使用磁场约束激光等离子体而使离子总束流提高了5倍,并首次使用了高频再游离措施,发现效果很明显,使得离子总束流提高了3倍。由此可见,可以利用脉冲激光产生等离子体的一些特殊性质来研究和改善ECR离子源的一些基本性质。 此外,在本论文中还介绍了2.45GHz ECR离子源实验台的设计和初步调试。
Resumo:
The gas-phase ion-molecule reactions of C-60 with the methoxymethyl ion [CH3O=CH2](+) and the 1-hydroxyethyl ion [CH3CH=OH](+) generated under the self-chemical-ionization (self-CI) conditions of alkyl methyl ethers and primary alcohols were studied in the ion source of a mass spectrometer. The adduct ions [C60C2H5O](+) and protonated molecules [C60H](+) were observed as the major products of C-60 with the plasma of alkyl methyl ethers. On the contrary, the reactions of C-60 With the plasmas of primary alcohols produced few corresponding adduct ions. The AM1 semiempirical molecular orbital calculations were carried out on 14 possible structures. The calculated results showed that the most stable structure among the possible isomers of [C60C2H5O](+) is the [3+2] cycloadduct. According to experimental and theoretical results, the pathway for the formation of the adduct was presented.