62 resultados para in-beam gamma-ray spectroscopy


Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Search for low-spin signature inversion in the pi i(13/2) circle times nu i(13/2) bands in odd-odd Au-182,Au-184,Au-186 has been conducted through the standard in-beam gamma-spectroscopy techniques. The experiments for Au-182 and 186Au have been performed in the Japan Atomic Energy Agency (JAEA) via the Sm-152(Cl-35,5n)Au-182 and Yb-172(F-19,5n)Au-186 reactions, respectively. A study of Au-184 has been made using a multi-detector array GASP in LNL, Italy, via the Tb-159(Si-29,4n)Au-184 reaction. The pi i(13/2) circle times nu i(13/2) bands in these three nuclei have been identified and extended up to high-spin states. In particular, the inter-band connection between the pi i(13/2) nu i(13/2) band and the ground-state band in 184 Au has been established, leading to a firm spin-and-parity assignment for the pi i(13/2) circle times nu i(13/2) band. The low-spin signature inversion is found in the pi i(13/2) circle times nu i(13/2) bands in Au-182,Au-184,Au-186 according to our spin-assignment and the signature crossing observed at high-spin states.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Irradiation has been widely reported to damage organisms by attacking on proteins, nucleic acid and lipids in cells. However, radiation hormesis after low-dose irradiation has become the focus of research in radiobiology in recent years. To investigate the effects of pre-exposure of mouse brain with low-dose C-12(6+) ion or Co-60 gamma (gamma)-ray on male reproductive endocrine capacity induced by subsequent high-dose irradiation, the brains of the B6C3F(1) hybrid strain male mice were irradiated with 0.05 Gy of C-12(6+) ion or Co-60 gamma-ray as the pre-exposure dose, and were then irradiated with 2 Gy as challenging irradiation dose at 4 h after pre-exposure. Serum pituitary gonadotropin hormones, follicle-stimulating hormone (FSH) and luteinizing hormone (LH), testosterone, testis weight, sperm count and shape were measured on the 35th day after irradiation. The results showed that there was a significant reduction in the levels of serum FSH, LH, testosterone, testis weight and sperm count, and a significant increase in sperm abnormalities by irradiation of the mouse brain with 2 Gy of C-12(6+) ion or Co-60 gamma-ray. Moreover, the effects were more obvious in the group irradiated by C-12(6+) ion than in that irradiated by Co-60 gamma-ray. Pre-exposure with low-dose C-12(6+) ion or Co-60 gamma-ray significantly alleviated the harmful effects induced by a subsequent high-dose irradiation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A standard in-beam gamma-spectroscopy experiment for Pt-188 is performed via the Yb-176(O-18, 6n) reaction at beam energies of 88 and 95 MeV, and the level scheme for (188) Pt is established. Prolate and oblate shape coexistence has been demonstrated to occur in Pt-188 by applying the projected shell model. The rotation alignment of i(13/2) neutrons drives the yrast sequence changing suddenly from prolate to oblate shape at angular momentum 10th, indicating likely a new type of shape phase transition along the yrast line in Pt-188.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have investigated the performance of a EXOGAM-Segmented-Clover with 16 segments as a Compton polarimeter to measure the linear polarization of gamma rays. The polarization sensitivity of the Clover detector has been measured at the energy of 1332keV through the coincidence measurements of cascade gamma-rays from Co-60. Experimental values were in good accord with our expectation.We have investigated the performance of a EXOGAM-Segmented-Clover with 16 segments as a Compton polarimeter to measure the linear polarization of gamma rays. The polarization sensitivity of the Clover detector has been measured at the energy of 1332keV through the coincidence measurements of cascade gamma-rays from Co-60. Experimental values were in good accord with our expectation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Search for low-spin signature inversion in the pi i(13/2) circle times nu i(13/2) bands in odd-odd Au-182,Au-184,Au-186 has been conducted through the standard in-beam gamma-spectroscopy techniques via the Sm-152(Cl-35,5n) Au-182, Yb-172(F-19,5n) (186)An, and Tb-159(Si-29,4n) (184)An reactions, respectively. The pi i(13/2) circle times nu i(13/2) bands in these three nuclei have been identified and extended up to high-spin states. In particular, the inter-band connection between the pi i(13/2) circle times nu i(13/2) band and the ground-state band in Au-184 has been established, leading to a firm spin-and-parity assignment for the pi i(13/2) circle times nu i(13/2) band. The low-spin signature inversion is found in the pi i(13/2) circle times nu i(13/2) bands according to our spin-assignment and-the signature crossing observed at high-spin states.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Excited states in Tl-188,Tl-190 have been studied experimentally by means of in-beam gamma spectroscopy techniques, and resulted in the identification of a strongly coupled band based on the pi h(9/2) circle times nu i(13/2) configuration with oblate deformation. The oblate band in doubly odd Tl nuclei shows low-spin signature inversion. It is the first experimental observation of low-spin signature inversion for a band associated with the oblate pi h(9/2) circle times nu i(13/2) configuration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The brain of the Kun-Ming strain mice were irradiated with 0.05 Gy of C-12(6+) ion or Co-60 gamma-ray as the pre-exposure dose, and were then irradiated with 2 Gy of 12C6+ ion or Co-60 gamma-ray as challenging irradiation dose at 4 h after per-exposure. Body weight and serum growth hormone (GH) concentration were measured at 35th day after irradiation. The results showed that irradiation of mouse brain with 2 Gy of C-12(6+) ion or Co-60 gamma-ray significantly diminished mouse body weight and level of serum GH. The relative biological effectiveness values of a 2 Gy dose of C-12(6+) ion calculated with respect to Co-60 gamma-ray were 1.47 and 1.34 for body weight and serum GH concentration, respectively. Pre-exposure with a low-dose (0.05 Gy) of C-12(6+) ion or Co-60 gamma-ray significantly alleviated reductions of mouse body weight and level of serum GH induced by a subsequent high-dose (2 Gy) irradiation. The data suggested that low-dose ionizing irradiation can induce adaptive hormetic responses to the harmful effects of pituitary by subsequent high-dose exposure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A high detection efficiency calorimeter which is used to detect gamma-rays with energies from 1 MeV up to 10 MeV as well as light charged particles has been proposed. Design of the geometry, results of the crystal tests and Monte Carlo simulations are presented in this paper. The simulation results confirm that the calorimeter can obtain high detection efficiency and good energy resolution with the current designed geometry. And the calorimeter is competent for the future External Target Facility (ETIF) experiments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Macromolecule-protected sub-micrometer polyhedral gold nanocrystals have been facilely prepared by heating an aqueous solution containing poly (N-vinyl-2-pyrrolidone) (PVP) and HAuCl4 without adding other reducing agents. Scanning electron microscopy (SEM), energy-dispersive x-ray spectroscopy (EDX), ultraviolet-visible-near-infrared spectroscopy (UV-vis-NIR), and x-ray diffraction (XRD) were employed to characterize the obtained polyhedral gold nanocrystals. It is found that the 10:1 molar ratio of PVP to gold is a key factor for obtaining quasi-monodisperse polyhedral gold nanocrystals. Furthermore, the application of polyhedral gold nanocrystals in surface-enhanced Raman scattering (SERS) was investigated by using 4-aminothiophenol (4-ATP) as a probe molecule. The results indicated that the sub-micrometer polyhedral gold nanocrystals modified on the ITO substrate exhibited higher SERS activity compared to the traditional gold nanoparticle modified film. The enhancement factor (EF) on polyhedral gold nanocrystals was about six times larger than that obtained on aggregated gold nanoparticles (similar to 25 nm).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Large area (25 mm(2)) silicon drift detectors and detector arrays (5x5) have been designed, simulated, and fabricated for X-ray spectroscopy. On the anode side, the hexagonal drift detector was designed with self-biasing spiral cathode rings (p(+)) of fixed resistance between rings and with a grounded guard anode to separate surface current from the anode current. Two designs have been used for the P-side: symmetric self-biasing spiral cathode rings (p(+)) and a uniform backside p(+) implant. Only 3 to 5 electrodes are needed to bias the detector plus an anode for signal collection. With graded electrical potential, a sub-nanoamper anode current, and a very small anode capacitance, an initial FWHM of 1.3 keV, without optimization of all parameters, has been obtained for 5.9 keV Fe-55 X-ray at RT using a uniform backside detector.