211 resultados para Temperature range


Relevância:

70.00% 70.00%

Publicador:

Resumo:

The heat capacity (C-p) of nanocrystalline nickel (nc-Ni, 40 mn crystallite size) has been measured over the temperature range of 78-370 K with a high-resolution automated adiabatic calorimeter. The measured results are compared with the C-p values of the corresponding coarse-grained crystal, and an enhancement of heat capacity of the nanocrystalline nickel was observed to be 2-4% in the temperature range between 100 and 370 K. The thermal stability of the nanocrystalline nickel sample was determined by a differential scanning calorimeter and a thermogravimetric system. The melting point of nc-Ni is the same as that of the corresponding coarse-grained crystalline nickel and the sample is stable at temperature lower than 500 K. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The temperature dependence of the resistivity of KrF laser irradiated polyimide films was studied. In all cases, the resistivity decreased with increasing temperature. The irradiated polyimide film exhibited a typical semiconducting property. This result indicated that the irradiated polyimide films can be used as temperature-sensitive materials. We demonstrated that both the sensitivity and the sensitive temperature range of the irradiated polyimide films can be altered by adjusting laser irradiation parameters. The intrinsic relationship between the temperature coefficient of the resistivity and irradiation condition was interpreted in terms of the microstructural change. The result provided a new insight into the fundamental aspects of laser irradiated polyimide film structure and a method of preparing temperature-sensitive materials. (C) 2000 Elsevier Science B.V. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A new amorphous comblike polymer (CBP) based on methylvinyl ether/maleic anhydride altering copolymer backbone and on oligooxyethylene side chain was synthesized. The dynamic mechanical properties of CBP and its Li salt complexes were investigated by means of DDV-11-EA type viscoelastic spectrometry. Results showed that there were two glass transitions (alpha-transition and beta-transition) in the temperature range from -100 to 100 degrees C. The beta-transition was assigned to oligo-PEO side chains and the temperature of beta-transition increases with increasing Li salt content. The alpha-transition was assigned to the main chain of CBP. The temperature of the alpha-transition (T-alpha) is also dependent upon the Li-salt content, but not monotonic. The value of T-alpha lies between 30-45 degrees C in the Li salt concentration range studied, near room temperature. It was found that the CBP-Li salt complexes showed an unusual dependence of ionic conductivity on Li salt content. There are two peaks in the plot of the ionic conductivity vs. Li salt concentration, which has been ascribed to the movability of the CBP main chain at ambient temperature. The temperature dependence bf the ionic conductivity indicated that the Arrhenius relationship was not obeyed, and the plot of log sigma against 1/(T - T-0) showed the unusual dual VTF behavior when using side chain glass transition temperature (T-beta) as T-0.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A strong strain-rate and temperature dependence was observed for the fracture toughness of phenolphthalein polyether ketone (PEK-C). Two separate crack-blunting mechanisms have been proposed to account for the fracture-toughness data. The first mechanism involves thermal blunting due to adiabatic heating at the crack tip for the high temperatures studied. In the high-temperature range, thermal blunting increases the fracture toughness corresponding to an effectively higher test temperature. However, in the low-temperature range, the adiabatic temperature rise is insufficient to cause softening and Jic increases with increasing temperature owing to viscoelastic losses associated with the p-relaxation there. The second mechanism involves plastic blunting due to shear yield/flow processes at the crack tip and this takes place at slow strain testing of the single-edge notched bending (SENB) samples. The temperature and strain-rate dependence of the plastic zone size may also be responsible for the temperature and strain-rate dependence of fracture toughness.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A new chiral liquid crystal with Schiff base group has been prepared, The structure of liquid crystal was confirmed by elementary analyses and H-1 NMR. Its phase transition was investigated by polarized optical microscope, DSC and temperature-depending FTIR spectra. The results showed that the chiral Schiff base showed monotropic phases behavior in certain temperature range, the phase sequence is I-N-*-S-B-S-G-K on the cooling sequence.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Laminaria japonica, Undaria pinnatifida, Ulva lactuca, Grateloupia turuturu and Palmaria palmata are Suitable species that fit the requirements of a seaweed-animal integrated aquaculture system in terms of their viable biomass, rapid growth and promising nutrient uptake rates. fit this investigation, the responses of the optimal chlorophyll fluorescence yield of the five algal species in tumble Culture were assessed at a temperature range of 10 similar to 30 degrees C. The results revealed that Ulva lactuca was the most resistant species to high temperature, withstanding 30 degrees C for 4 h without apparent decline in the optimal chlorophyll fluorescence yield. While the arctic alga Palmaria palmata was the most vulnerable one, showing significant decline in the optimal chlorophyll fluorescence yield at 25 degrees C for 2 h. The cold-water species Laminaria japonica, however, demonstrated strong ability to cope with higher temperature (24 similar to 26 degrees C) for shorter time (within 24 h) without significant decline in the optimal chlorophyll fluorescence yield. Grateloupia turuturu showed a general decrease in the optimal chlorophyll fluorescence yield with the rising temperature from 23 to 30 degrees C, similar to the temperate kelp Undaria pinnatifida. Changes of chlorophyll fluorescence yields of these algae were characterized differently indicating the existence of species-unique strategy to cope with high light. Measurements of the optimal chlorophyll fluorescence yield after short exposure to direct solar irradiance revealed how long these exposures could be without significant photoinhibition or with promising recovery in photosynthetic activities. Seasonal pattern of alternation of algal species in tank culture in the Northern Hemisphere at the latitude of 36 degrees N was proposed according to these basic measurements.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

We studied the influence of temperature on the spawning performance of artificially matured Japanese eels, Anguilla japonica, in captivity. We used routine hormone injections to bring females and males to maturity in separate aquaria. We recorded the behavior of three pairs of such hormone-treated matured eels in an aquarium (2 replicates) at four temperatures: 14, 18, 22, and 27 degrees C, respectively. They became active and frequently left the bottom swimming in the water column, and spawning events occurred. Females released eggs in the water column around the activity peaks. Males preceded females in reaching activity peaks (presumably the timing of sperm ejection and egg release), possibly resulting in the low fertilization we observed in this experiment. Males and females returned back to the aquarium bottoms and became quiet after spawning. On several occasions, male-female or female-female pairs were observed to 'cruise together' in the water column for several to tens of seconds prior to egg releasing, but no courtship behavior indicative of spawning such as pairing and chasing was observed in the eels in our study. Our results suggest that 18-22 degrees C might be the thermal preference for spawning for Japanese eels, which approximates the temperature range of the 500 m deep water layer around the Mariana Islands seamount area, the presumed spawning site for the Japanese eel.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A continuous spatial temperature gradient was established in capillary electrophoresis by using a simple temperature control device. The temperature profile along the capillary was predicted by theoretical calculations. A nearly linear spatial temperature gradient was established and applied to DNA mutation detection. By spanning a wide temperature range, it was possible to perform simultaneous heteroduplex analysis for various mutation types that have different melting temperatures.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

To study the transport mechanism of hydrophobic organic chemicals (HOCs) and the energy change in soil/solvent system, a soil leaching column chromatographic (SLCC) experiment at an environmental temperature range of 20-40 degreesC was carried out, which utilized a reference soil (SP 14696) packed column and a methanol-water (1:4 by volume ratio) eluent. The transport process quickens with the increase of column temperature. The ratio of retention factors at 30 and 40 degreesC (k'(30)/k'(40)) ranged from 1.08 to 1.36. The lower enthalpy change of the solute transfer in SLCC (from eluent to soil) than in conventional reversed-phase liquid chromatography (e.g., from eluent to C-18) is consistent with the hypothesis that HOCs were dominantly and physically partitioned between solvent and soil. The results were also verified by the linear solvation energy relationships analysis. The chief factor controlling the retention was found to be the solute solvophobic partition, and the second important factor was the solute hydrogen-bond basicity, while the least important factors were the solute polarizability-dipolarity and hydrogen-bond acidity. With the increase of temperature, the contributions of the solute solvophobic partition and hydrogen-bond basicity gradually decrease, and the latter decreases faster than the former. (C) 2002 Elsevier Science Ltd. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The heat capacities of crystalline and liquid n-hexatriacontane were measured with an automatic adiabatic calorimeter over the temperature range of 80-370 K. Two solid-to-solid phase transitions at the temperatures of 345.397 and 346.836 K, and a fusion at the temperature of 348.959 K have been observed. The enthalpies and entropies of these phase transitions as well as the chemical purity of the substance were determined on the basis of the heat capacity measurements. Thermal decomposition temperatures of the compound were measured by thermogravimetric analysis. (C) 1999 Elsevier Science B.V. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Molar heat capacities of ( S)-ibuprofen were precisely measured with a small sample precision automated adiabatic calorimeter over the temperature range from 80 to 370 K. Experimental heat capacities were fitted into a polynomial equation of heat capacities ( C-p,C- m) with reduced temperature ( X), [ X = f(T)]. The polynomial equations for ( S)-ibuprofen were C-p,C- m(s) = - 39.483 X-4 - 66. 649 X-3 + 95. 196 X-2 + 210. 84 X + 172. 98 in solid state and C-p,C- m(L) = 7. 191X(3) + 4. 2774 X-2 + 56. 365 X + 498. 5 in liquid state. The thermodynamic functions relative to the reference temperature of 298. 15 K, H-T - H-298.15 and S-T - S-298.15, were derived for the( S)-ibuprofen. A fusion transition at T-m = (324. 15 +/- 0. 02) K was found from the C-p - T curve. The molar enthalpy and entropy of the fusion transition were determined to be (18. 05 +/- 0. 31) kJ.mol(-1) and (55. 71 +/- 0. 95) J.mol(-1).K-1, respectively. The purity of the ( S)-ibuprofen was determined to be 99. 44% on the basis of the heat capacity measurement. Finally, the heat capacities of ( S)-ibuprofen and racemic ibuprofen were compared.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The ionization kinetics of sodium diluted in argon is studied in a shock tube, in which the test gas mixture is ionized by a reflected shock wave and subsequently quenched by a strong rarefaction wave. A Langmuir electrostatic probe is used to monitor the variation of the ion number density at the reflection shock wave region. The working state of the probe is in the near fi-ee fall region and a correction for reduction of the probe current due to elastic scattering in the probe sheath is introduced. At the temperature range of 800 to 2600 K and in the ambience of argon gas, the three-body recombination rate coefficient of the sodium ion with electron is determined: 3.43 x 10(-14)T(-3.77) cm(6).s(-1).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

JP-10 (exo-tetrahydrodicyclopentadiene, C10H16) ignition delay times were measured in a preheated shock tube. The vapor pressures of the JP-10 were measured directly by using a high-precision vacuum gauge, to remedy the difficulty in determining the gaseous concentrations of heavy hydrocarbon fuel arising from the adsorption on the wall in shock tube experiments. The whole variation of pressure and emission of the OH or CH radicals were observed in the ignition process by a pressure transducer and a photomultiplier with a monochromator. The emission of the OH or CH radicals was used to identify the time to ignition. Experiments were performed over the pressure range of 151-556 kPa, temperature range of 1000-2100 K, fuel concentrations of 0.1%-0.55% mole fraction, and stoichiometric ratios of 0.25, 0.5, 1.0 and 2.0. The experimental results show that for the lower and higher temperature ranges, there are different dependency relationships of the ignition time on the temperature and the concentrations of JP-10 and oxygen.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper, torsion fracture behavior of drawn pearlitic steel wires with different heat treatments was investigated. Samples with different heat treatments was investigated. Samples with different heat treatment conditions were subjected to torsion and tensile tests. The shear strain along the torsion sample after fracture was measured. Fracture surface of wires was examined by Scanning Electron Microscopy. In addition, the method of Differential Scanning Calorimetry was used to characterize the thermodynamic process in the heat treatment. A numerical simulation via finite element method on temperature field evolution for the wire during heat treatment process was performed. The results show that both strain aging and recovery process occur in the material within the temperature range between room temperature and 435 degrees C. It was shown that the ductility measured by the number of twists drops at short heating times and recovers after further heating in the lead bath of 435 degrees C. On the other hand, the strenght of the wire increases at short heating times and decreases after further heating. The microstructure inhomogeneity due to short period of heat treatment, coupled with the gradient characteristics of shear deformation during torsion results in localized shear deformation of the wire. In this situation, shear cracks nucleate between lamella and the wire breaks with low number of twists.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Thermal cracking of China No.3 aviation kerosene was studied experimentally and analytically under supercritical conditions relevant to regenerative cooling system for Mach-6 scramjet applications. A two-stage heated tube system with cracked products collection/analysis was used and it can achieve a fuel temperature range of 700-1100 K, a pressure range of 3.5-4.5 MPa and a residence time of approximately 0.5-1.3 s. Compositions of the cracked gaseous products and mass flow rate of the kerosene flow at varied temperatures and pressures were obtained experimentally. A one-step lumped model was developed with the cracked mixtures grouped into three categories: unreacted kerosene, gaseous products and residuals including liquid products and carbon deposits. Based on the model, fuel conversion on the mass basis, the reaction rate and the residence time were estimated as functions of temperature. Meanwhile, a sonic nozzle was used for the control of the mass flow rate of the cracked kerosene, and correlation of the mass flow rate gives a good agreement with the measurements.