71 resultados para Rhodamine 6G
Resumo:
Rhodamine B (RB)-doped organic-inorganic silica films and their patterning were fabricated by a sol-gel process combined with a soft lithography. The resulted film samples were characterized by atomic force microscope (AFM), optical microscope and UV/Vis absorption and photoluminescence excitation and emission spectra. The effects of the concentration of the RB dye and heat treatment temperature on the optical properties of the hybrid silica films have been studied. Four kinds of patterning structures with film line widths of 5, 10, 20 and 50 mum have been obtained by micromolding in capillaries by a soft lithography technique. The RB-doped hybrid silica films present a red color, with an excitation and emission bands around 564 and 585 mum, respectively. With increasing the RB concentration, the emission intensity of the RB-doped hybrid silica films increases and the emission maximum presents a red shift. The emission intensity of the films decreases with increasing the heat treatment temperatures.
Resumo:
测量了R6G/二甲苯红B二元混合染料体系的荧光光谱、荧光寿命和激光输出性能。表明它可作激光工作物质。定量地计算了R6G/二甲苯红B分子间的能量转移效率E、能量转移速率常数R_(et)及临界距离R_0,研究了分子间能量转移的过程和主要机制。
Simultaneous Laser-Induced Fluorescence And Contactless-Conductivity Detection For Microfluidic Chip
Resumo:
A combined detection system involving simultaneous LIF and contactless-conductometric measurements at the same place of the microfluidic chip was described. The LIF measurement was designed according to the confocal principle and a moveable contactless-conductivity detector was used in (CD)-D-4. Both measurements were mutually independent and advantageous in analyses of mixtures. Various experimental parameters affecting the response were examined and optimized. The performances were demonstrated by simultaneous detection of Rhodamine B. And the results showed that the combined detection system could be used sensitively and reliably. (C) 2008 Yong Yu. Published by Elsevier B.V. on behalf of Chinese Chemical Society. All rights reserved.
Resumo:
A new dual simultaneous detector was developed for capillary electrophoresis microchip. Confocal laser-induced fluorescence (LIF) and moveable contactless conductivity detection (MCCD) were combined together for the first time. The two detection systems shared a common detection cell and could respond simultaneously. They were mutually independent and advantageous in analyses of mixtures containing organic and inorganic ions. The confocal LIF had high sensitivity and the MCCD could move along the separation channel and detect in different positions of the channel. The detection conditions of the dual detector were optimized. Rhodamine B was used to evaluate the performance of the dual detector. The limit of detection of the confocal LIF was < 5 nM, and that of the MCCD was 0.1 mu M. The dual detector had highly sensitivity and could offer response easily, rapidly and simultaneously.
Resumo:
Excimer laser ablation technique was introduced into this work to fabricate a passive planar micromixer on the PMMA substrate. T-junction shaped and width-changed S-shaped microchannels were both designed in this micromixer to enhance mixing effect. The mixing experiment of distilled water and Rhodamine B with injection flow rate of 500 and 1,500 mu m/s validates the mixing effectivity of this micromixer, and indicates the feasibility of excimer laser ablation in the microfabrication of mu-TAS device.
Resumo:
A new dual simultaneous detector was developed for capillary electrophoresis microchip. Confocal laser-induced fluorescence (LIF) and moveable contactless conductivity detection (MCCD) were combined together for the first time. The two detection systems shared a common detection cell and could respond simultaneously. They were mutually independent and advantageous in analyses of mixtures containing organic and inorganic ions. The confocal LIF had high sensitivity and the MCCD could move along the separation channel and detect in different positions of the channel. The detection conditions of the dual detector were optimized. Rhodamine B was used to evaluate the performance of the dual detector. The limit of detection of the confocal LIF was <5 nM, and that of the MCCD was 0.1 μM. The dual detector had highly sensitivity and could offer response easily, rapidly and simultaneously.
Resumo:
以共焦显微系统为平台,研究了不同浓度的R6G银溶胶的表面增强共振拉曼散射(SERRS)光谱,结果表明不同浓度溶液中的R6G分子表现出了不同的光谱特性。在浓度为10^-13mol·L^-1的R6G银溶胶中得到了R6G单分子的表面增强共振拉曼散射光谱,观察到了一些光谱非均匀变化现象,如谱色散、谱线的强度起伏、拉曼谱的偏振化以及分子的闪烁等,并对这些现象进行了分析,证明得到的是R6G单分子的SERRS光谱。文章还对单分子检测中的一些关键问题进行了分析与讨论,确定了单分子SERRS光谱检测的适当条件。
Resumo:
采用几何光学方法对共焦系统扫描时产生的扫描深度与厚度失真进行了理论分析,对名义扫描深度与实际扫描深度之间的关系进行了研究.以若丹明6G薄膜与玻片组成的多层样品为模型,对其进行了模拟计算,得到了扫描深度与厚度失真与系统数值孔径、折射率和样品厚度之间的关系.在实验上分别采用单光子荧光和双光子荧光作为检测信号,在反射式共焦扫描系统上进行了纵向扫描实验,并与模拟计算的结果进行了比较和分析.
Resumo:
Only the first- order Doppler frequency shift is considered in current laser dual- frequency interferometers; however; the second- order Doppler frequency shift should be considered when the measurement corner cube ( MCC) moves at high velocity or variable velocity because it can cause considerable error. The influence of the second- order Doppler frequency shift on interferometer error is studied in this paper, and a model of the second- order Doppler error is put forward. Moreover, the model has been simulated with both high velocity and variable velocity motion. The simulated results show that the second- order Doppler error is proportional to the velocity of the MCC when it moves with uniform motion and the measured displacement is certain. When the MCC moves with variable motion, the second- order Doppler error concerns not only velocity but also acceleration. When muzzle velocity is zero the second- order Doppler error caused by an acceleration of 0.6g can be up to 2.5 nm in 0.4 s, which is not negligible in nanometric measurement. Moreover, when the muzzle velocity is nonzero, the accelerated motion may result in a greater error and decelerated motion may result in a smaller error.
Resumo:
为了减少由于加速度所导致的激光双频干涉仪测量误差,引入二阶多普勒频移,建立了由被测物体加速度所引起的测量误差的理论模型。仿真结果表明,在0.4s时间内0.6g加速度所引起的累积误差可达2.5 nm左右,这对于纳米精度的测量是不应忽视的; 初速度不为零时加速运动会引起更大的误差,而减速运动所引起的误差则相对小。通过实验验证,所测的误差变化趋势与理论模拟比较吻合。
Resumo:
By using an Ar+ ion laser, a tunable Rh 6G dye laser(Linewidth : 0.5 cm(-1)) and a Coherent 899-21 dye laser as light sources and using a monochromator and a phase-locking amplifier, the optical properties of Eu3+ : Y2SiO5 crystal were detected. Persistent spectral hole burning (PSHB) were also observed in (5)Do-(7)Fo transition in the crystal at the temperature of 16 K. For 15 mW dye laser (Wavelength : 579.62 nm) burning the crystal for 0.1 s a spectral hole with about 80 MHz hole width were detected and the hole can been keep for longer than 10 h.
Resumo:
分别利用氩离子激光,二倍频YAG:Nd激光泵浦的诺明6G可调谐窄线宽(0.5cm^-1)染料激光和899-21可调谐染料激光作为光源,以单色仪-锁相放大器-光电倍增管-计算机数据采集系统记录光谱,对Y2SiO5:Eu^3+晶体进行了光谱和光谱烧孔研究。在常温和液氮温度下测量了晶体的激发光谱、荧光光谱等。在16K温度下对晶体进行了光谱烧孔研究,得到了孔宽约80MHz并能保存10h的永久性光谱孔。
Resumo:
本研究通过对玉簪属植物的组织培养,发现以腋芽、花序、试管苗的叶片为外植体,均可达到迅速繁殖的目的,但对于不同的玉簪品种来说,所能采用的外植体的种类又不尽相同:对于非嵌合体玉簪品种,以腋芽、花序、试管苗的叶片作外植体都可以;而对于嵌合体玉簪品种,如果以花序或试管苗的叶片为外植体,通过诱导不定芽进行快繁,在所得的试管苗中,超过50%的个体失去斑叶特性,这在实际生产中是不可行的,如果以腋芽为外植体,所得试管苗中多于95%的可保持原有嵌合体特征,故为理想的外植体。 在以腋芽为外植体的离体培养中,取嵌合玉簪品种H. ‘Francee’和H. ‘Ground Master’的芽作材料,通过对试验结果的分析、比较,选出了合适的繁殖培养基:MS + BA0.5mg/L + NAA0.5mg/L + KH2PO4150mg/L + 水解乳蛋白500mg/L + 蔗糖30g/L + 琼脂 5.6g/L,其可提高腋芽分化率,达到了快速繁殖的目的,此外,该培养基还可保持原来的生长势,降低斑叶特性分离比;同时选出了生根培养基:MS + IAA1mg/L + 蔗糖30g/L + 琼脂5.6g/L。 以花葶为外植体的试验,证实了此种方式仅适合非嵌合体玉簪的快速繁殖。 在以叶片为外植体的研究中,取了嵌合体品种H. ‘Francee’、H. ‘Ground Master’、H. ‘Gold Standard’、H. ‘Color Glory’和H. ‘Little Ming’的再生叶征作材料,通过对试验结果的分析、比较、观察到在培养基:MS + BA4mg/L + NAA0.1mg/L + 蔗糖 30g/L + 琼脂 5.6g/L上只有芽的形成,培养基:MS + BA0.4mg/L + NAA0.4mg/L + 蔗糖 30g/L + 琼脂 5.6g/L则利于根的发生,而培养基:MS + BA4mg/L + NAA0.4mg/L + 蔗糖 30g/L + 琼脂 5.6g/L促进根或(和)不定芽的产生,则因品种的不同而变化,另外还发现,经诱导不定芽途径所得到的试管苗,仅少于5%的个体保持斑叶特性,所以不可用于嵌合体玉簪的组织培养,但可快速繁殖非嵌合体玉簪。
Resumo:
采用三种方法对扁担塘长角涵螺的周年生产量进行了测算 ,结果表明 ,三种方法得到的生产量及P/B系数吻合较好。生产量的带壳湿重和去壳干重分别是 :体长频率法 ,2 .0 88g·m 2 ·a 1 ,0 .1 0 3g·m 2 ·a 1 ;Allen曲线法 ,2 .1 2 2g·m 2 ·a 1 ,0 .1 0 6g·m 2 ·a 1 ;瞬时生长率法 ,2 .2 73g·m 2 ·a 1 ,0 .1 1 4g·m 2 ·a 1 。对应的P/B系数为 4.3 ,4.3 ,4.0。