35 resultados para Length-frequency analysis


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The mode frequency and the quality factor of nanowire cavities are calculated from the intensity spectrum obtained by the finite-difference time-domain (FDTD) technique and the Pade approximation. In a free-standing nanowire cavity with dielectric constant epsilon = 6.0 and a length of 5 mu m, quality factors of 130, 159, and 151 are obtained for the HE11 modes with a wavelength around 375 nm, at cavity radius of 60, 75, and 90 nm, respectively. The corresponding quality factors reduce to 78, 94, and 86 for a nanowire cavity standing on a sapphire substrate with a refractive index of 1.8. The mode quality factors are also calculated for the TE01 and TM01 modes, and the mode reflectivities are calculated from the mode quality factors.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The eigenmodes confined in the equilateral triangle resonator (ETR) are analyzed by deriving the eigenvalues and the mode field distributions and by the finite difference time domain (FDTD) technique. The analytical results show that the one-period-length for the mode light rays inside the ETR is the perimeter of the ETR, and the number of transverse modes is limited by the condition of total internal reflection. In addition, the sum of the longitudinal mode index and the transverse mode index should be an even number, which limits the number of confined modes again. Based on the FDTD technique and the Pade approximation, we calculate the mode resonant frequencies and the quality factors from the local maximum and the width of the spectral distribution of the intensity The numerical results of mode frequencies agree very well with the analytical results, and the quality factor of the fundamental mode is usually higher than that of the higher order transverse modes. The results show that the ETR is suitable to realize single-made operation as semiconductor microcavity lasers.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The measurement and analysis of the microwave frequency response of semiconductor optical amplifiers (SOAs) are proposed in this paper. The response is measured using a vector network analyzer. Then with the direct-subtracting method, which is based on the definition of scattering parameters of optoelectronic devices, the responses of both the optical signal source and the photodetector are eliminated, and the response of only the SOA is extracted. Some characteristics of the responses can be observed: the responses are quasi-highpass; the gain increases with the bias current; and the response becomes more gradient while the bias current is increasing. The multisectional model of an SOA is then used to analyze the response theoretically. By deducing from the carrier rate equation of one section under the steady state and the small-signal state, the expression of the frequency response is obtained. Then by iterating the expression, the response of the whole SOA is simulated. The simulated results are in good agreement with the measured on the three main characteristics, which are also explained by the deduced results. This proves the validity of the theoretical analysis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fast analysis of ofloxacin and lidocaine, as bactericide and analgesic or anesthetics, is of clinic importance for understanding the patient's medical process. This paper presented a high throughput, simple analysis method of lidocaine and ofloxacin by capillary electrophoresis coupled with electrochemiluminescence (ECL) using porous etched joint. To shorten the analysis time and to improve the analytical performance, a capillary with 10 cm in length was used as the separation channel. The cyclic voltammograms of Ru(bpy)(3)(2+) with different capillary length at same field strength showed that the porous etched joint eliminated the effect of electrophoretic current on the ECL detection. Following micro total analysis systems (muTAS), some advantages of which this approach has, the fabrication of channel in chip was not needed. Compared with capillary electrophoresis with 40-cm-long capillary, the high sample throughput and low zone broadening may be the main advantage of the present system. Under optimal condition, the detection limits of lidocaine and ofloxacin based on peak height were 3.0 x 10(-8) and 5.0 x 10(-7) mot L-1 and a 60 h(-1) of sampling frequency was obtained.