33 resultados para LIQUID HELIUM-II


Relevância:

30.00% 30.00%

Publicador:

Resumo:

New poly(azomethine sulfones) with linear structures containing sulfonyl bis(4-phenoxyphenylene) and oxo bis(benzylideneaniline) or methylene bis(benzylideneaniline) units were prepared in the conventional literature manner by condensing the dialdehyde sulfone monomer (V) with diamines such as 4,4'-oxydianiline (IIIa) and 4,4'-methylenedianiline (IIIb), or by condensing an azomethine biphenol (IX) with 4,4'-sulfonyldichlorobenzene (II). Three model compounds which reproduced the above structures were also synthesized. The resulting polymers were confirmed by IR, H-1-NMP, and elemental analysis, and were characterized by inherent viscosities, thermogravimetric analysis (TGA), and x-ray diffraction. The thermotropic liquid crystalline (TLC) behavior was studied using polarization light microscopy (PLM), thermooptical analysis (TOA), and DSC. A nematic texture was observed only for 4,4'-oxydianiline-units-based polymers. The reaction of polymer VIIIb containing -CH2- links between the mesogens with the model compound IX led to polymer X which exhibited TLC behavior.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dicyanobis(1,10-phenanthroline)iron(II)-modified glassy carbon electrodes were shown to exhibit an electrocatalytic response for the oxidation of acetaminophen with a decrease of 100 mV in the potential required. It can also inhibit the oxidation of ascor

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Amperometic flow measurements were made at +0.55 V (vs. Ag/AgCl) in 0.1 mol l-1 KOH electrolyte with an Ni(II) chemically modified electrode (CME) with an Eastman-AQ polymer film. The use and characteristics of a Ni(II)-containing crystalline and polymer-modified electrode obtained by a double coating step as a detector for amino acids in a flow-injection system using reversed-phase liquid chromatography are described. The detection of these analytes is based on the higher oxidation state of nickel (NiOOH) controlled by the applied potential. The electroanalytical parameters and the detection current for a series of amines and amino acids were investigated. The use of such a CME in the flow-injection technique was found to be suitable in a solution at low pH. The linear range for glycine is 5 X 10(-6)-0.1 mol 1-1 with a detection limit of 1.0 X 10(-6) mol l-1. A 1 X 10(-4) mol 1-1 mixture of serine and tyrosine was also detected after separation on an Nucleosil C18 column.