346 resultados para LASER SPECTROMETRY


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A study on the interactions of high intensity (similar to 10(16) W/cm(2)) femtosecond laser pulses with rare gas clusters in a dense jet is performed. Energy absorption by Ar and Xe clusters is measured and it can be as high as 90%. Very energetic ions produced in the laser interaction with a dense cluster jet are detected by time-of-flight spectrometry and the maximum ion energy of Xe is up to 1.3 MeV. The average ion energies are found to increase with increasing cluster size and get saturated gradually. The average ion energies also show a strong directionality and the average ion energy in the direction parallel to the laser polarization vector is 40% higher than that perpendicular to it. The findings are discussed in terms of a model of charge-dependent ion acceleration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Laser-induced breakdown spectroscopy (LIBS) as a powerful analytical technique is applied to analyze trace-elements in fresh plant samples. We investigate the LIBS spectra of fresh holly leaves and observe more than 430 lines emitted from 25 elements and molecules in the region 230-438 nm. The influence of laser wavelength on LIBS applied to semi-quantitative analysis of trace-element contents in plant samples is studied. The results show that the UV laser has lower relative standard deviations and better repeatability for semi-quantitative analysis of trace-element contents in plant samples. This work may be helpful for improving the quantitative analysis power of LIBS applied to plant samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cluster assisted photoionization processes of benzene, which was seeded in argon, induced by an intense 25 ns Nd-YAG laser has been studied by means of time-of-flight mass spectrometry. At the laser intensity of 10(11) W/cm(2), multicharged ions Cq+ (q = 2-3) with kinetic energy up to 150 eV were observed in the mass spectra. Strong evidences Support that these ions are formed in the Coulomb explosion of multicharged benzene cluster ions. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report a novel method termed matrix suppressed laser desorption/ionization to improve the analysis of low-mass molecules by MALDI-TOF mass spectrometry. In this method, the surfactant of cetrimonium bromide (CTAB) is added to the conventional matrix of alpha-cyano-4-hydroxycinnamic acid solution to prepare the MALDI samples. During the MALDI process, the presence of CTAB could substantially or even completely suppress the matrix-related ion background. As a result, very clean mass spectra can be routinely obtained in the low-mass range. In addition, the presence of CTAB can significantly improve the mass resolution of low-mass molecules. It is seen that high-quality spectra were routinely obtained at a matrix/CTAB ratio of 1000:1. This method has been successfully used to analyze a variety of low-mass molecules.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High-resolution Fourier transform ion cyclotron resonance (FTICR) mass spectrometry was developed and applied to the proteome analysis of bronchoalveolar lavage fluid (BALF) from a patient with pulmonary alveolar proteinosis. With use of 1-D and 2-D gel electrophoresis, surfactant protein A (SP-A) and other surfactant-related lung alveolar proteins were efficiently separated and identified by matrix-assisted laser desorption/ionization FTICR mass spectrometry . Low molecular mass BALF proteins were separated using a gradient 2-D gel. An efficient extraction/precipitation system was developed and used for the enrichment of surfactant proteins. The result of the BALF proteome analysis show the presence of several isoforms of SP-A, in which an N-non-glycosylierte form and several proline hydroxylations were identified. Furthermore, a number of protein spots were found to contain a mixture of proteins unresolved by 2-D gel electrophoresis, illustrating the feasibility of high-resolution mass spectrometry to provide identifications of proteins that remain unseparated in 2-D gels even upon extended pH gradients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The determination of Nb and Ta in Nb-Ta minerals was accomplished by slurry nebulization inductively coupled plasma optical emission spectrometry (ICP-OES), using a clog-free V-groove ceramic nebulizer. Samples were first wet-ground to appropriate particle sizes with narrow size distribution and 90% of the particles in the slurry were smaller than 2.32 mu m in diameter. Subsamples were then dispersed in pH 9 aqueous solutions, and agitated in an ultrasonic bath for 15 min prior to analysis. Due to the lack of slurry standards matching well with the samples, calibration was simply carried out using aqueous solution standards. Results were compared with those obtained from a conventional fusion decomposition procedure and acid digestion procedures and a good agreement between the measured and referred values was obtained. The technique provided a good alternative for the rapid determination of Nb and/or Ta in their corresponding minerals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Single-colour and two-colour multiphoton resonant ionization spectra of uranium atom were studied extensively with a Nd: YAG laser-pumped dye laser atomic beam apparatus time-of-flight mass spectrometer in our laboratory. The energy locations of high-lying odd-parity levels in the region 33 003-34 264 cm(-1),mearured by a two-colour three-step ionization technique, were reported here. The angular momentum quantum number J was uniquely assigned for these levels by using angular momentum selection rules.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Combination of affinity extraction procedures with mass spectrometric analyses is termed affinity-directed mass spectrometry, a technique that has gained broad interest in immunology and is extended here with several improvements from methods used in previous studies. A monoclonal antibody was immobilized on a nitrocellulose (NC) membrane, allowing the corresponding antigen to be selectively captured from a complex solution for analysis by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). This method was also used to rapidly determine the approximate binding region responsible for the antibody/antigen interaction. The tryptic fragments of antigen protein in buffer were applied to the antibody immobilized on NC film and allowed to interact. The NC film was then washed to remove salts and other unbound components, and subjected to analysis by MALDI-TOFMS. Using interferon-alpha (2a) and anti-interferon-alpha (2a) monoclonal antibody IgG as a model system, we successfully extracted the antigen protein and determined the approximate binding region for the antigen/antibody interaction (i.e., the tryptic fragment responsible). Copyright (C) 2001 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The behavior of electrical conductivity for excimer laser irradiated polyimide films in the vicinity of the critical number of laser shots was described by three-dimensional percolative phase transition model. It is: found that electrical conductivity changed more rapidly than that predicted by the percolation model. Thus, the change in microstructure with increasing number of laser shots was analyzed by FT-IR Raman spectrometry and laser desorption time-of-flight mass spectrometry. It is demonstrated that not only the number but also the average size of graphite particles on the irradiated polyimide film surfaces increased with increasing number of laser shots. These results were helpful to better understand the critical change in electrical conductivity on the irradiated polyimide film surfaces. (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An experimental setup and the procedure for the laser resonant ionization mass spectrometry (RIMS) have been described. Both an optical spectrum and a mass spectum have been shown. The detection limit that can be reached by using this procedure has been estimated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) was used to analyze two enzymes, phospholipase AZ and fibrinolytic enzyme isolated from Chinese Agkistrodon blomhoffii Ussurensis venom. Using sinapinic acid as the matrix, positive ion mass spectra of the enzymes were obtained, In addition to the dominant protein [M+H](+) ions, multimeric and multiply charged ions were also observed in the mass spectra, The higher the concentration of the enzymes, the more multiply charged polymer and multimeric ions were detected, Our results indicate that MALDI-TOFMS can provide a rapid and accurate method for molecular weight determination of snake venom enzymes, Mass accuracies of 0.1 and 0.3 % were achieved by analysis of highly dialyzed phospholipase A2 and fibrinolytic enzyme, and these results are much better than those obtained using sodium dodecyl sulfate-palyacrylamide gel electrophoresis. MALDI-TOFMS thus provides a reliable method to determine the purity and molecular weight of these enzymes, which are of potential use as therapeutants, Copyright (C) 1999 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Matrixassisted laser desorption/ionization (MALDI) mass spectra of saccharides with three common matrixes were studied here. It is shown that Na+ and K+ play important roles in the determination of oligasaccharide molecule weight and the molecular weights (MW) of glucans(dextran) with MW more than 10 000 is determined successfully with the help of column chromatography, By comparing the effects of three matrixes in saccharide analysis and comparing positive-ion and negative-ion matrixassisted laser desorption/ionization mass spectra of oligo- and polysaccharides, the most suitable matrix for saccharide analysis, 2,5-dihydroxylbezonic acid (DHB), is selected and the ion formation processes of saccharides under matrix-assisted laser adsorption/ionization condition are clarified.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Molecular weight of 8 ginsenosides and the component of total saponions in American ginseng have been determined by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). The average error of the molecular weight of each ginsenoside was found less than 0.05%. The results demonstrate that MALDI-MS is a very simple and useful method to measure the molecular weight of some high polar, thermal unstable small molecules with high sensitivity and reproducibility.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ⅰ. INTRODUCTIONLaser-excited atomic fluorescence spectrometry in hollow cathode discharge(HCD) has been widely used in the research field of laser spectroscopy in recent years. Similar to traditional method, information obtained in the researches was direct line nonresonance fluorescence arising from the resonantly transitional upper level. Attention has not been sufficiently paid to the phenomenon of population change on the resonantly transitional lower level due to laser irradiation of plasma in HCD,...