98 resultados para Feature detector


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The K-best detector is considered as a promising technique in the MIMO-OFDM detection because of its good performance and low complexity. In this paper, a new K-best VLSI architecture is presented. In the proposed architecture, the metric computation units (MCUs) expand each surviving path only to its partial branches, based on the novel expansion scheme, which can predetermine the branches' ascending order by their local distances. Then a distributed sorter sorts out the new K surviving paths from the expanded branches in pipelines. Compared to the conventional K-best scheme, the proposed architecture can approximately reduce fundamental operations by 50% and 75% for the 16-QAM and the 64-QAM cases, respectively, and, consequently, lower the demand on the hardware resource significantly. Simulation results prove that the proposed architecture can achieve a performance very similar to conventional K-best detectors. Hence, it is an efficient solution to the K-best detector's VLSI implementation for high-throughput MIMO-OFDM systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A realistic measurement setup for a system such system measured by a mesoscopie detector,is theoretically as a charged two-state (qubit) or multi-state quantum studied. To properly describe the measurement-induced back-action,a detailed-balance preserved quantum master equation treatment is developed. The established framework is applicable for arbitrary voltages and temperatures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A SiGe/Si multi-quantum wells resonant-cavity-enhanced(RCE) detector with high reflectivity bottom mirror is fabricated by a new method.The bottom mirror is deposited in the hole,which is etched from the backside of the sample by ethylenediamine-pyrocatechol-water(EPW) solution with the buried SiO2 layer in SOI substrate as the etching-stop layer.Reflectivity spectrum indicates that the mirror deposited in the hole has a reflectivity as high as 99% in the range of 1.2~1.5μm.The peak responsivity of the RCE detector at 1.344μm is 1.2mA/W and the full width at half maximum is 12nm.Compared with the conventional p-i-n photodetector,the responsivity of RCE detector is enhanced 8 times.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Large area (25 mm(2)) silicon drift detectors and detector arrays (5x5) have been designed, simulated, and fabricated for X-ray spectroscopy. On the anode side, the hexagonal drift detector was designed with self-biasing spiral cathode rings (p(+)) of fixed resistance between rings and with a grounded guard anode to separate surface current from the anode current. Two designs have been used for the P-side: symmetric self-biasing spiral cathode rings (p(+)) and a uniform backside p(+) implant. Only 3 to 5 electrodes are needed to bias the detector plus an anode for signal collection. With graded electrical potential, a sub-nanoamper anode current, and a very small anode capacitance, an initial FWHM of 1.3 keV, without optimization of all parameters, has been obtained for 5.9 keV Fe-55 X-ray at RT using a uniform backside detector.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To achieve a better time resolution of a scintillator-bar detector for a neutron wall at the external target facility of HIRFL-CSR,we have carried out a detailed study of the photomultiplier,the wrapping material and the coupling media. The timing properties of a scintillator-bar detector have been studied in detail with cosmic rays using a high and low level signal coincidence. A time resolution of 80 ps has been achieved in the center of the scintillator-bar detector.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper a two dimensional readout micromegas detector with a polyethylene foil as converter was simulated on GEANT4 toolkit and GARFIELD for fast neutron detection. A new track reconstruction method based on time coincidence technology was developed in the simulation to obtain the incident neutron position. The results showed that with this reconstruction method higher spatial resolution was achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In present paper, a new Micromegas detector is developed, and its time and energy signals are obtained in the figure form. The rising time of fast time signal is less than 2 ns due to the very fast collection of avalanche electrons, and the rising time of the energy pulse is about 100 ns, which is corresponding to the total collecting time of the electrons and ions in the avalanche process. The counter plateau, energy resolution and the gas gains of the detector have been compared with other groups' experimental results and the Garfield simulation result.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The necessity of installing a forward tracking detector stack is discussed for the Hadron Physics LanzhoU Spectrometer(HPLUS). A local tracker is developed to solve the multi-track finding problem. The track candidates are searched iteratively via Hough Transform. The fake tracks are removed by a least square fitting process. With this tracker we have studied the feasibility of pp -> pp + phi(-> K+K-), a typical physical channel proposed on HPLUS. The single track momentum resolution due to the uncertainty of the positioning in FTD is 1.3%. The multiple scattering effect contributes about 20% to the momentum resolution in the FTD coverage. The width and the signal-to-background ratio of the reconstructed phi are 1.51 MeV and 4.36, respectively, taking into account the direct Kaon channel pp -> pp + K+K- as background. The geometry coverage of FTD for phi events is about 85.4%. Based on the current fast simulation and estimation, the geometrical configuration of FTD meets the physical requirement of HPLUS under the current luminosity and multiplicity conditions. The tracker is applicable in the full simulation coming next and is extendable to other tracking component of HPLUS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The research of the in-beam efficiency calibration of Neutron Detector Array of Peking University using N-17 and C-16 beams was introduced in this paper. The efficiency of neutron wall and ball are comparable to the foreign similar devices and neutrons can be detected from low to high energies in high efficiency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new non-linear comparison method of charge-division readout scheme is conceived and the first design of a multi-hit two-dimensional position-sensitive energy spectrum Si(Au) surface barrier detector with a continuous sensitive area is proposed.