58 resultados para Fault compensation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electronic structure of a bounded intrinsic stacking fault in silicon is calculated. The method used is an LCAO-scheme (Linear Combinations of Atomic Orbitals) taking ten atomic orbitals of s-, p-, and d-type into account. The levels in the band gap are extracted using Lanczos' algorithm and a continued fraction representation of the local density of states. We find occupied states located up to 0.3 eV above the valence band maximum (E(v)). This significantly differs from the result obtained for the ideal infinite fault for which the interface state is located at E(v)+ 0.1 eV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of alpha-power chirped fiber Bragg gratings for dispersion cancellation in an optical fiber link is discussed. Numerical and theoretical investigation of recompressing the dispersion-broadened pulse by using alpha-power chirped gratings is made, which shows that, the dispersion-broadened Gaussian pulse after 100 km standard fiber (with zero dispersion at lambda = 1.3 mu m) trnasmission at lambda = 1.55 mu m with initial width of T-FWHM = 33ps (full width at half maximum) can be perfectly recompressed with the peak reflectivity of 82% by using a 30 mm long alpha-power chirped fiber grating with proper a value and optimal grating parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a fast-settling frequency-presetting PLL frequency synthesizer. A mixed-signal VCO and a digital processor are developed to accurately preset the frequency of VCO and greatly reduce the settling time. An auxiliary tuning loop is introduced in order to reduce reference spur caused by leakage current. The digital processor can automatically compensate presetting frequency variation with process and temperature, and control the operation of the auxiliary tuning loop. A 1.2 GHz integer-N synthesizer with 1 MHz reference input Was implemented in a 0.18μm process. The measured results demonstrate that the typical settling time of the synthesizer is less than 3μs,and the phase noise is -108 dBc/Hz@1MHz.The reference spur is -52 dBc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have experimentally demonstrated pulses 0.4 mJ in duration smaller than 12 fs with an excellent spatial beam profile by self-guided propagation in argon. The original 52 fs pulses from the chirped pulsed amplification laser system are first precompressed to 32 fs by inserting an acoustic optical programmable dispersive filter instrument into the laser system for spectrum reshaping and dispersion compensation, and the pulse spectrum is subsequently broadened by filamentation in an argon cell. By using chirped mirrors for post-dispersion compensation, the pulses are successfully compressed to smaller than 12 fs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Respiration-induced target motion is a major problem in intensity-modulated radiation therapy. Beam segments are delivered serially to form the total dose distribution. In the presence of motion, the spatial relation between dose deposition from different segments will be lost. Usually, this results in over-and underdosage. Besides such interplay effects between target motion and dynamic beam delivery as known from photon therapy, changes in internal density have an impact on delivered dose for intensity-modulated charged particle therapy. In this study, we have analysed interplay effects between raster scanned carbon ion beams and target motion. Furthermore, the potential of an online motion strategy was assessed in several simulations. An extended version of the clinical treatment planning software was used to calculate dose distributions to moving targets with and without motion compensation. For motion compensation, each individual ion pencil beam tracked the planned target position in the lateral aswell as longitudinal direction. Target translations and rotations, including changes in internal density, were simulated. Target motion simulating breathing resulted in severe degradation of delivered dose distributions. For example, for motion amplitudes of +/- 15 mm, only 47% of the target volume received 80% of the planned dose. Unpredictability of resulting dose distributions was demonstrated by varying motion parameters. On the other hand, motion compensation allowed for dose distributions for moving targets comparable to those for static targets. Even limited compensation precision (standard deviation similar to 2 mm), introduced to simulate possible limitations of real-time target tracking, resulted in less than 3% loss in dose homogeneity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It has been found that charge compensated CaMoO4:Eu3+ phosphors show greatly enhanced red emission under 393 and 467 nm-excitation, compared with CaMoO4:Eu3+ without charge compensation. Two approaches to charge compensation, (a) 2Ca(2+) -> EU3+ + M+, where M+ is a monovalent cation like Li+, Na+ and K+ acting as a charge compensator; (b) 3Ca(2+) -> 2EU(3+) + vacancy, are investigated. The influence of sintering temperature and Eu3+ concentration on the luminescent property of phosphor samples is also discussed.