77 resultados para FLOW-INJECTION


Relevância:

70.00% 70.00%

Publicador:

Resumo:

The chelates formed between the heavy metal ion Pb(II) and the reagents 8-hydroxy-5-quinolinesulphonic acid, 8-hydroxy-7-quinolinesulphonic acid and 8-hydroxy-7-iodo-5-quinolinesulphonic acid exhibit strong room temperature phosphorescence (RTP) if retained on the surface of anion exchange resin beads. Based on the on-line formation, in a flow-injection system, of such RTP lead chelates and their transient immobilization on an anion exchange resin, three flow-through optosensing systems are investigated for lead in sea water. Optimum experimental conditions and the analytical performance characteristics of the three optosensors are discussed. Relative standard deviations (RSDs) of the order of 3% are typical at 100 ng ml−1 Pb(II) and the active sensing phases can easily be regenerated by passing 500 μl of 6 M hydrochloric acid. A lead(II) detection limit of 0.1 ng ml−1 (3×background SD, for 2 ml sample injection volumes) was achieved for the optosensor based on 8-hydroxy-7-quinolinesulphonic acid. Possible interferences present in sea water, including cations and anions which could affect the sensor response, are discussed in detail. Finally, the selected RTP flow-through optical sensor has been successfully tested for the determination of lead in sea water at a few ng ml−1.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A novel flow injection optical fiber biosensor for glucose based on luminol electrochemiluminescence (ECL) is presented. The sol-gel method is introduced to immobilize glucose oxidase (GOD) on the surface of a glassy carbon electrode. After optimization of the working conditions, glucose could be quantitated in the concentration ranges between 50 muM and 10 mM with a detection limit of around 26 muM. Signal reproducibility was about 3.62% relative standard deviation for 11 replicated measurements of 0.1 mM glucose. The ECL biosensor also showed good selectivity and operational stability. The proposed method can be applied to determination of glucose in soft drink samples.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A chemically modified electrode (CME) constructed by adsorption of aquocobalamin (VB12a) onto a glassy carbon electrode surface was demonstrated to catalyze the electro-oxidation of cysteine, a sulfhydryl-containing compound. The sulfhydryl oxidation occured at 0.54-0.88 V vs. Ag/AgCl depending on pH value (3.0-10.0). The electrocatalytic behavior of cysteine is elucidated with respect to solution pH, operating potential and other variables as well as the CME preparation conditions. When used as the sensing electrode in flow injection amperometric detection, the CME permitted detection of the compound at 0.8 V. The detection limit was 1.7 pmol. The linear response range went up to 1.16 nmol. The stability of the CME was shown by RSD (4.2%) over 10 repeated injections.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

利用长期肥料定位试验,监测旱地农田土壤硝态氮的淋溶动向,研究施肥量与硝态氮累积量之间的关系,为科学施肥提供参考。【方法】在试验小区0~300cm土壤剖面中,每20cm深度取一个土样,1mol·L-1KCl浸提后以AA3连续流动分析仪测定硝态氮含量。【结果】单施氮肥土壤硝态氮累积峰出现在80~100cm土层和300cm以下土层,当施氮量达到180kg·hm-2·a-1时,0~300cm土层硝态氮累积总量相当于8年的施氮量。单施磷肥对土壤硝态氮分布无影响;氮、磷肥配施时,施氮量增加硝态氮累积量显著增加,配施磷肥后可以减少硝态氮累积量,且施氮量越大减少的越多。过量施用氮肥,即使配施磷肥,硝态氮也能发生淋溶并在100~120cm和240~260cm土层附近累积;二次多项式回归能够较好地反映氮、磷施用量与土壤硝态氮累积量之间的关系。【结论】长期过量施用氮肥,导致硝态氮大量淋溶并形成两个累积峰,科学合理地配施磷肥可以减少硝态氮淋失;旱地麦田长期施用最大产量施肥量,可能导致硝态氮大量累积在土壤深层。

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A flow injection system for the determination of organophosphate and carbamate pesticides is described. A sensitive fluorescence probe was synthesized and used as the pH indicator to detect the inhibition of the enzyme acetylcholinesterase (ACNE). The percentage inhibition of enzyme activity is correlated to the pesticide concentration. Several parameters influencing the performance of the system are discussed. The detection limits of 3.5, 50, 12 and 25 mug/l for carbofuran, carbaryl, paraoxon and dichlorvos, in pure water, respectively were achieved with an incubation time of 10 min. A complete cycle of analysis, including incubation time, took 14 min. The detection system has been applied to the determination of carbofuran in spiked vegetable juices (Chinese cabbage and cole), achieving recovery values between 93.2 and 107% for Chinese cabbage juice and 108 and 118% for cole juice at the different concentration levels assayed. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A slab optical waveguide (SOWG) has been used for study of adsorption of both methylene blue (MB) and new methylene blue (NMB) in liquid-solid interface. Adsorption characteristics of MB and NMB on both bare SOWG and silanized SOWG by octadecyltrichlorosilane (ODS) were compared. The simultaneous determinations of both MB and NMB were explored by flow injection SOWG spectrophotometric analysis and artificial neural networks (ANNs) for the first time. Concentrations of MB and NMB were estimated simultaneously with the ANNs. Results obtained with SOWG were compared with those got by conventional UV-visible spectrophotometry. (C) 2003 Elsevier Science B.V All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Phenothiazine drugs, chlorpromazine hydrochloride (CPZ) and promethazine hydrochloride (PMZ), were determined with Ru(bpy)(3)(2+) electrochemiluminescene by the capillary electrophoresis (CE-ECL). It was found that both CPZ and PMZ could produce an intermediate that acted as coreactants to react with Ru(bpy)(3)(2+) to produce excited states which were capable of emitting light. This CE-ECL detection method had high sensitivity, good selectivity and reproducibility for CPZ and PMZ determination.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Laccase has been immobilized on the carbon nanotubes modified glassy carbon electrode surface by adsorption. As-prepared laccase retains good electrocatalytic activity to oxygen reduction by using 2,2'-azino-bis-(3-ethylbenzthiazoline-6-sulfonic acid) as the mediator. It can be used as a biosensor for the determination of catechol with broad linear range.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A new kind of bismuth film modified electrode to sensitively detect trace metal ions based on incorporating highly conductive ionic liquids 1-butyl-3-methyl-imidazolium hexafluorophosphate (BMIMPF6) in solid matrices at glassy carbon (GC) was investigated. Poly(sodium 4-styrenesulfonate) (PSS), silica, and Nafion were selected as the solid matrices. The electrochemical properties of the mixed films modified GC were evaluated. The electron transfer rate of Fe(CN)(6)(4-)/Fe(CN)(6)(3-) can be effectively improved at the PSS-BMIMPF6 modified GC.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An electrochemiluminescence (ECL) sensor based on Ru(bpy)(3)(2+)-graphene-Nafion composite film was developed. The graphene sheet was produced by chemical conversion of graphite, and was characterized by atomic force microscopy (AFM), scanning electron microscopy (SEM), and Raman spectroscopy. The introduction of conductive graphene into Nafion not only greatly facilitates the electron transfer of Ru(bpy)(3)(2+), but also dramatically improves the long-term stability of the sensor by inhibiting the migration of Ru(bpy)(3)(2+) into the electrochemically inactive hydrophobic region of Nafion. The ECL sensor gives a good linear range over 1 x 10(-7) to 1 x 10(-4) M with a detection limit of 50 nM towards the determination of tripropylamine (TPA), comparable to that obtained by Nafion-CNT.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Among various ECL systems, such as 9,10-diphenylanthracene, lucigenin, tris(2,2'-bipyridyl) ruthenium, peroxyoxalate, luminol, graphene, and nanocrystals, Ru(bpy)(3)(2+) ECL is one of the most widely studied ECL systems in recent years due to its broad applications in immunoassays, DNA probe assays, coreactants analysis, and aptasensors. In this review, the progress in Ru(bpy)(3)(2+) ECL has been summarized on the whole, and the future research trends have been proposed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work herein reports the approach for the simultaneous determination of heavy metal ions including cadmium (Cd(II)), lead (Pb(II)), and chromium (Cr(VI)) using a bismuth film electrode (BFE) by anodic stripping voltammertry (ASV). The BFE used was plated in situ. Due to the reduction of Cr(VI) with H2O2 in the acid medium, on one hand, the Cr(III) was produced and Cr(VI) was indirectly detected by monitoring the content of Cr(III) using square-wave ASV. On the other hand, Pb(II) was also released from the complex between Pb(II) and Cr(VI). Furthermore, the coexistence of the Cd(II) was also simultaneously detected with Pb(II) and Cr(VI) in this system as a result of the formation of an alloy with Bi. The detection limits of this method were 1.39 ppb for Cd(II), 2.47 ppb for Pb(II) and 5.27 ppb for Cr(VI) with a preconcentration time of 120 s under optimal conditions (S/N = 3), respectively. Furthermore, the sensitivity of this method can be improved by controlling the deposition time or by using a cation-exchange polymer (such as Nafion) modified electrode.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The electrochemiluminescence (ECL) of tris(2,29-bipyridyl) ruthenium(II) [Ru(bpy)(3)(2+)] ion-exchanged in the sulfonic-functionalized MCM-41 silicas was developed with tripropylamine (TPrA) as a co-reactant in a carbon paste electrode (CPE) using a room temperature ionic liquid (IL) as a binder. The sulfonic-functionalized silicas MCM-41 were used for preparing an ECL sensor by the electrostatic interactions between Ru( bpy)(3)(2+) cations and sulfonic acid groups. We used the IL as a binder to construct the CPE (IL-CPE) to replace the traditional binder of the CPE (T-CPE)-silicone oil. The results indicated that the MCM-41-modified IL-CPE had more open structures to allow faster diffusion of Ru( bpy)(3)(2+) and that the ionic liquid also acted as a conducting bridge to connect TPrA with Ru( bpy)(3)(2+) sites immobilized in the electrode, resulting in a higher ECL intensity compared with the MCM-41-modified T-CPE. Herein, the detection limit for TPrA of the MCM-41-modified IL-CPE was 7.2 nM, which was two orders of magnitude lower than that observed at the T-CPE. When this new sensor was used in flow injection analysis (FIA), the MCM-41-modified IL-CPE ECL sensor also showed good reproducibility. Furthermore, the sensor could also be renewed easily by mechanical polishing whenever needed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Capillary electrophoresis (CE) coupling with a tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)(3)(2+)) electrochemiluminescence (ECL) detection technique was developed for the analysis of two 8-blockers, atenolol (AT) and metoprolol (ME). The parameters that influence the separation and detection, including the buffer pH and concentration, the separation voltage, the detection potential and Ru(bpy)(3)(2+) concentration, were optimized in detail. The calibration curve was linear over a concentration range of two or three orders of magnitude for the two beta-blockers. The detection limits for AT and ME were 0.075 and 0.005 mu M (S/N = 3). The relative standard deviations (n = 8) of the ECL intensity and the migration time were 2.65 and 0.22% for AT, 2.82 and 0.34% for ME, respectively. The proposed method was applied to determine AT and ME in spiked urine samples; satisfactory results were obtained.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This article presents the state of the art of analytical applications of the electrochemiluminescence (ECL) of tris (2,2'-bipyridyl) ruthenium (Ru(bpy)(3)(2+)) and its derivatives. in the last seven years, Ru(bpy)(3)(2+) ECL has attracted much interest from analysts and been successfully exploited as a detector of flow injection analysis (FIA), high-performance liquid chromatography (HPLC), capillary electrophoresis (CE), and micro total analysis systems (TAS). Immobilization of Ru(bPY)(3)(2+) on a solid surface provides several advantages over the solution-phase ECL procedure, such as the simplicity of experimental design and cost-effectiveness. After a brief discussion of the mechanism of Ru(bpy)(3)(2+) ECL, we discuss its applications in FIA, HPLC, CE and TAS and give special attention to the design of Ru(bpy)(3)(2+) ECL cells and some immobilization techniques of Ru(bpy)(3)(2+); we focus on papers published after 1997.