43 resultados para microstrip open stub


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Source levels of echolocating free-ranging Yangtze finless porpoise (Neophocaena phocaenoides asiaeorientalis) were calculated using a range estimated by measuring the time delays of the signals via the surface and bottom reflection paths to the hydrophone, relative to the direct signal. Peak-to-peak source levels for finless porpoise were from 163.7 to 185.6 dB re:1 mu Pa. The source levels are highly range dependent and varied approximately as a function of the one-way transmission loss for signals traveling from the animals to the hydrophone. (c) 2006 Acoustical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

By viewing the non-equilibrium transport setup as a quantum open system, we propose a reduced-density-matrix based quantum transport formalism. At the level of self-consistent Born approximation, it can precisely account for the correlation between tunneling and the system internal many-body interaction, leading to certain novel behavior such as the non-equilibrium Kondo effect. It also opens a new way to construct time-dependent density functional theory for transport through large-scale complex systems. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High speed visualizations and thermal performance studies of pool boiling heat transfer on copper foam covers were performed at atmospheric pressure, with the heating surface area of 12.0 mm by 12.0 mm, using acetone as the working fluid. The foam covers have ppi (pores per inch) from 30 to 90, cover thickness from 2.0 to 5.0 mm, and porosity of 0.88 and 0.95. The surface superheats are from -20 to 190 K, and the heat fluxes reach 140 W/cm(2). The 30 and 60 ppi foam covers show the periodic single bubble generation and departure pattern at low surface superheats. With continuous increases in surface superheats, they show the periodic bubble coalescence and/or re-coalescence pattern. Cage bubbles were observed to be those with liquid filled inside and vented to the pool liquid. For the 90 ppi foam covers, the bubble coalescence takes place at low surface superheats. At moderate or large surface superheats, vapor fragments continuously escape to the pool liquid. Boiling curves of copper foams show three distinct regions. Region I and II are those of natural convection heat transfer, and nucleate boiling heat transfer for all the foam covers. Region III is that of either a resistance to vapor release for the 30 and 60 ppi foam covers, or a capillary-assist liquid flow towards foam cells for the 90 ppi foam covers. The value of ppi has an important effect on the thermal performance. Boiling curves are crossed between the high and low ppi foam covers. Low ppi foams have better thermal performance at low surface superheats, but high ppi foams have better one at moderate or large surface superheats and extend the operation range of surface superheats. The effects of other factors such as pool liquid temperature, foam cover thickness on the thermal performance are also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the principles of microwave circuits and semiconductor device physics, two microwave power device test circuits combined with a test fixture are designed and simulated, whose properties are evaluated by a parameter network analyzer within the frequency range from 3 to 8GHz. The simulation and experimental results verify that the test circuit with a radial stub is better than that without. As an example, a C-band AlGaN/GaN HEMT microwave power device is tested with the designed circuit and fixture. With a 5.4GHz microwave input signal, the maximum gain is 8.75dB, and the maximum output power is 33.2dBm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Open-tube Ga diffusion into a SiO2/Si structure was used for fabrication of the high speed thyristor. The advantages of open-tube Ga diffusion are as follows; it is easier to operate and easier to control the profile of the Ga concentration during processing, a clean surface, which is free from alloy spots can be obtained, this technique ensures to improve the on-state characteristics and dynamic characteristics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The coupling mechanism of thermocapillary convection and evaporation effect in evaporating liquids was studied experimentally. The experiments were carried out to study a thin evaporating liquid layer in a rectangular test cell when the upper surface was open to air. By altering the imposed horizontal temperature differences and heights of liquid layers, the average evaporating rate and interfacial temperature profiles were measured. The flow fields were also visualized by PIV method. For comparison, the experiments were repeated by use of another two non-evaporating liquids to study the influence of evaporation effect. The results reveal evidently the role that evaporation effect plays in the coupling with thermocapillary convection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

硅微条探测器通过微电子工艺制作,易因沾污导致性能下降甚至失效;裸露的键合引线,也易因机械力形成隐性或显性失效。对上述现象的研究可用于修复、维护探测器并在设计和工艺流程中改进其性能。本文通过光学、电气手段分析其结构和制作工艺流程,根据沾污性质在不同条件下清洗探测器,中测后根据芯片图形、封装方式和电气要求修复探测器,最后采用同位素α能谱测试修复效果。对一块沾污后失效(无法加载偏压)的硅微条清洗后在大气环境,N面接地,P面加载负偏压条件下进行了测试,结果显示:170 V全耗尽,平均漏电流2.94μA,5.486 MeV的α峰能量分辨率约1.28%。失效键合所在条的另一面各条能谱观测到假峰,键合修复后消除。因沾污失效的硅微条探测器经过合适的清洗、修复,部分可以恢复性能,但清洗对表面和结构有损伤,须谨慎。另外,键合失效后,因信号不能引出导致的电荷积累会通过电容效应影响其它灵敏区。文章提示,探测器应存放于洁净,恒温,低湿度,避光,避强电磁干扰的环境,以提高能量和位置分辨率,并增加工作稳定性,延长使用寿命。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

“Dissolved” (< 0.4 μm filtered) and “total dissolvable” (unfiltered) trace element samples were collected using “clean” sampling techniques from four vertical profiles in the eastern Atlantic Ocean on the first IOC Trace Metals Baseline expedition. The analytical results obtained by 9 participating laboratories for Mn, Fe, Co, Ni, Cu, Zn, Cd, Pb, and Se on samples from station 4 in the northeast Atlantic have been evaluated with respect to accuracy and precision (intercomparability). The data variability among the reporting laboratories was expressed as 2 × SD for a given element and depth, and was comparable to the 95% confidence interval reported for the NASS seawater reference standards (representing analytical variability only). The discrepancies between reporting laboratories appear to be due to inaccuracies in standardization (analytical calibration), blank correction, and/or extraction efficiency corrections.Several of the sampling bottles used at this station were not adequately pre-cleaned (anomalous Pb results). The sample filtration process did not appear to have been a source of contamination for either dissolved or particulate trace elements. The trace metal profiles agree in general with previously reported profiles from the Atlantic Ocean. We conclude that the sampling and analytical methods we have employed for this effort, while still in need of improvement, are sufficient for obtaining accurate concentration data on most trace metals in the major water masses of the oceans, and to enable some evaluation of the biogeochemical cycling of the metals.