24 resultados para Test reliability


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Accelerating Moment Release (AMR) preceding earthquakes with magnitude above 5 in Australia that occurred during the last 20 years was analyzed to test the Critical Point Hypothesis. Twelve earthquakes in the catalog were chosen based on a criterion for the number of nearby events. Results show that seven sequences with numerous events recorded leading up to the main earthquake exhibited accelerating moment release. Two occurred near in time and space to other earthquakes preceded by AM R. The remaining three sequences had very few events in the catalog so the lack of AMR detected in the analysis may be related to catalog incompleteness. Spatio-temporal scanning of AMR parameters shows that 80% of the areas in which AMR occurred experienced large events. In areas of similar background seismicity with no large events, 10 out of 12 cases exhibit no AMR, and two others are false alarms where AMR was observed but no large event followed. The relationship between AMR and Load-Unload Response Ratio (LURR) was studied. Both methods predict similar critical region sizes, however, the critical point time using AMR is slightly earlier than the time of the critical point LURR anomaly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of the free-stream thermo-chemical state on the test model flow field in the high-enthalpy tunnel are studied numerically. The properties of the free-stream, which is in thermo-chemical non-equilibrium, are determined by calculating the nozzle flow field. A free-stream with total enthalpy equal to the real one in the tunnel while in thermo-chemical equilibrium is constructed artificially to simulate the natural atmosphere condition. The flow fields over the test models (blunt cone and Apollo command capsule model) under both the non-equilibrium and the virtual equilibrium free-stream conditions are calculated. By comparing the properties including pressure, temperature, species concentration and radiation distributions of these two types of flow fields, the effects of the non-equilibrium state of the free-stream in the high-enthalpy shock tunnel are analyzed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new 2-D quality-guided phase-unwrapping algorithm, based on the placement of the branch cuts, is presented. Its framework consists of branch cut placing guided by an original quality map and reliability ordering performed on a final quality map. To improve the noise immunity of the new algorithm, a new quality map, which is used as the original quality map to guide the placement of the branch cuts, is proposed. After a complete description of the algorithm and the quality map, several wrapped images are used to examine the effectiveness of the algorithm. Computer simulation and experimental results make it clear that the proposed algorithm works effectively even when a wrapped phase map contains error sources, such as phase discontinuities, noise, and undersampling. (c) 2005 Society of Photo-Optical Instrumentation Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new 2-D quality-guided phase-unwrapping algorithm, based on the placement of the branch cuts, is presented. Its framework consists of branch cut placing guided by an original quality map and reliability ordering performed on a final quality map. To improve the noise immunity of the new algorithm, a new quality map, which is used as the original quality map to guide the placement of the branch cuts, is proposed. After a complete description of the algorithm and the quality map, several wrapped images are used to examine the effectiveness of the algorithm. Computer simulation and experimental results make it clear that the proposed algorithm works effectively even when a wrapped phase map contains error sources, such as phase discontinuities, noise, and undersampling. (c) 2005 Society of Photo-Optical Instrumentation Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The encircled energy of a focusing lens is one of the parameters directly affecting the target efficiency in high-power laser facilities. The direct measurement method of the encircled energy for the focusing lens based on the scanning Hartmann test is proposed in this paper. With the scanning Hartmann test setup, the information in the whole aperture of the focusing lens can be achieved. The encircled energy can be obtained by analyzing the spot diagram on the focal plane of the focusing lens. In experiments, the encircled energy of an aspheric focusing lens is measured using this method. The measurement result is in good agreement with that derived from measurement data by an interferometer and the difference is 7.7%. (C) 2006 Elsevier GmbH. All rights reserved.