33 resultados para Strip mine ponds.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Test strip detectors of 125 mu m, 500 mu m, and 1 mm pitches with about 1 cm(2) areas have been made on medium-resistivity silicon wafers (1.3 and 2.7 k Ohm cm). Detectors of 500 mu m pitch have been tested for charge collection and position precision before and after neutron irradiation (up to 2 x 10(14) n/cm(2)) using 820 and 1030 nm laser lights with different beam-spot sizes. It has been found that for a bias of 250 V a strip detector made of 1.3 k Ohm cm (300 mu m thick) can be fully depleted before and after an irradiation of 2 x 10(14) n/cm(2). For a 500 mu m pitch strip detector made of 2.7 k Ohm cm tested with an 1030 nm laser light with 200 mu m spot size, the position reconstruction error is about 14 mu m before irradiation, and 17 mu m after about 1.7 x 10(13) n/cm(2) irradiation. We demonstrated in this work that medium resistivity silicon strip detectors can work just as well as the traditional high-resistivity ones, but with higher radiation tolerance. We also tested charge sharing and position reconstruction using a 1030 nm wavelength (300 mu m absorption length in Si at RT) laser, which provides a simulation of MIP particles in high-physics experiments in terms of charge collection and position reconstruction, (C) 1999 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During the last years FOPI has developed a new ToF system as an upgrade of the existing detector based on Multi-strip Multi-gap Resistive Plate Chambers (MMRPCs). The intention is to increase the charged Kaon identification up to a laboratory momentum of 1 GeV/c and to enhance the azimuthal detector granularity. The new ToF barrel has an active area of 5 m(2) with 2400 individual strips (900 x 1.6 mm(2)) [A. Schuttauf, et al., Nucl. Phys. B 158 (2006) 52] which are read out on both sides by a custom designed electronics [M. Ciobanu, et al., IEEE Trans. Nucl. Sci. NS-54 (4) (2007) 1201; K. Koch, et al., IEEE Trans. Nucl. Sci. NS-52(3) (2005) 745]. To reach the envisaged goal a time resolution of 100 ps is needed, at a flight path of 1-1.3 m. Due to the rare production of the K- at SIS energies the efficiency of the MMRPCs has to be above 95%. We report on measurements with the detectors and electronics from the mass production line. For this purpose we used a proton beam at 2.0 and 1.25 GeV, at rates between 0.1 and 5 kHz/cm(2) to determine the timing, efficiency and rate capability of the MMRPCs

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow injection amperometric immunoassay system based on the use of screen-printed carbon electrode for the detection of mouse IgG was developed. An immunoelectrode strip, on which an immunosorbent layer and screen-printed carbon electrode were integrated, and a proposed flow cell have been fabricated. The characterization of the flow immunoassay system and parameters affecting the performance of the immunoassay system were studied and optimized. Amperometric detection at 0.0 V (versus Ag/AgCl) resulted in a linear detection range of 30-700 ng ml(-1), with a detection limit of 3 ng ml(-1). The signal variation among electrode strips prepared from variant batch did not exceed 8.5% (n = 7) by measuring 0.5 mug ml(-1) antigen standard solution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two new urostylid ciliates, Metaurostylopsis songi n. sp. and Metaurostylopsis salina n. sp. and Metaurostylopsis marina (Kahl 1932) are investigated using live observation and protargol impregnation. These species were isolated in Korea from intertidal sediments, saline ponds, and coastal waters. Metaurostylopsis songi is in vivo about 120 pm x 25 mu m, has a slenderly ellipsoidal body, colorless cortical granules in rows on ventral and dorsal body sides, about 54 macronuclear nodules, 28-47 adoral membranelles, five frontal, two or three frontoterminal and six or seven transverse cirri, and 9-12 midventral cirral pairs followed posteriorly by 1-3 single cirri. In vivo M. salina is about 60 pin x 25 mu m, has a pyriform body, colorless cortical granules irregularly arranged, about 45 macronuclear nodules, 18-23 adoral membranelles, three frontal, three to five frontoterminal and two to five transverse cirri, and four or five midventral cirral pairs followed posteriorly by five to seven single cirri. Both species have three marginal cirral rows on each body side and 3 long dorsal kineties. The Korean specimens of M. marina match the Chinese population in all main features. Metaurostylopsis songi differs from M. marina by the more slender body, the number of frontal cirri (invariably five vs. four), and the arrangement of cortical granules (in rows on dorsal and ventral cortex vs. only along dorsal kinetics and anterior body margin). Metaurostylopsis salina differs from its congeners by the distinctly smaller size, the pyriform body shape, the scattered cortical granules (vs. in rows), and number of frontal cirri. It differs from M. marina also by the number of midventral cirral pairs (four or five vs. seven to 11).