53 resultados para Plate Library


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new method is presented here to analyse the Peierls-Nabarro model of an edge dislocation in a rectangular plate. The analysis is based on the superposition scheme and series expansions of complex potentials. The stress field and dislocation density field on the slip plane can be expressed as the first and the second Chebyshev polynomial series respectively. Two sets of governing equations are obtained on the slip plane and outer boundary of the rectangular plate respectively. Three numerical methods are used to solve the governing equations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a new pulse cleaning technique to enhance the contrast ratio of intense ultra-short laser pulses. A pulse temporal cleaner based on nonlinear ellipse rotation by using BK7 glass plate is developed, and a contrast ratio improvement of two orders of magnitude for the milli-joule level femtosecond input pulses is demonstrated, the total transmission efficiency of the pulse cleaner is 16.7%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a novel phase-shifting vectorial-shearing interferometer with a wedge plate phase-shifter. The interferometer is based on a modified Mach-Zehnder configuration; the common-path nature makes it capable of testing the wavefront of a short coherence-length light source, such as a laser diode. Vectorial shear (shearing in the x and y directions simultaneously) in an arbitrary direction is introduced by inserting two wedge plates orthogonally in two arms, respectively. One of the wedge plates is split into two parts (parallel part and wedge part); phase shift is produced by moving the wedge part in contact along the parallel part. The moving distance for a 2 pi phase shift is a few millimetres in specific conditions. The wedge plate phase-shifter increases the moving distance for phase shift and makes the control of phase shift relatively easy. We also discuss the lateral shear error and phase shift errors induced by wedge plates. The lateral shear error is small enough to be ignored; the phase shift error is determined mainly by the wedge angle error. Lastly, we give the experimental results of phase-shifting interference fringes in vectorial shear mode.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a novel highly sensitive wave front detection method for a quick check of a flat wave front by taking advantage of a non-zero-order pi phase plate that yields a non-zero-order diffraction pattern. When a light beam with a flat wave front illuminates a phase plate, the zero-order intensity is zero. When there is a slight distortion of the wave front, the zero-order intensity increases. The ratio of first-order intensity to that of zero-order intensity is used as the criterion with which to judge whether the wave front under test is flat, eliminating the influence of background light. Experimental results demonstrate that this method is efficient, robust, and cost-effective and should be highly interesting for a quick check of a flat wave front of a large-aperture laser beam and adaptive optical systems. (c) 2005 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A parallel plate interferometer with a reflecting mirror for measuring angular displacement is proposed. A deflection angle of a beam caused by an angular displacement is amplified by use of a reflecting mirror to increase the optical path difference (OPD) in the plane-parallel plate, which provides high sensitivity of the phase measurement. Detection of light transmitted through the plane-parallel plate with a position sensitive detector (PSD) enables high accurate measurement of the initial angle of incidence to the plane-parallel plate with insensitivity to stray light. The improved parallel plate interferometer achieves a measurement repeatability of 10(-8) rad. (C) 2007 The Optical Society of Japan.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The measurement accuracy of a parallel-plate interferometer for angular displacement measurement is analyzed. The measurement accuracy of angular displacement is not only related to the accuracy of phase extraction, but also related to initial incident angle, refraction index and thickness of plane-parallel plate as well as wavelength's stability of laser diode, etc. Theoretical analysis and computer simulation show that the measurement error of the angular displacement bears a minimum value when choosing an optimal initial incident angle in a large range. These analytical results serve as a guide in practical measurement. In this interferometer, reducing the refraction index or increasing the thickness of the parallel plate can improve the measurement accuracy; and the relative error of the phase measurement is 3.0 x 10(-4) corresponding to 1 degrees C temperature variation. Based on these theoretical and experimental results, the measurement accuracy of the parallel-plate interferometer is up to an order of 10(-8) rad. (c) 2007 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Superresolution is very important in imaging and optical storage systems, and has attracted much attention. In this article, concentric three-zone phase plate with 0, pi, 0 phase variation has been investigated numerically to show that this kind of phase plate can be used to obtain three-dimensional superresolution. In addition, the number of intensity maximum, focal depth, focal shift, full-width half-maximum, and relative intensity of side lobe are listed for different radii of the phase zones, which paves the way for design of the phase plate. Therefore, one can choose values of radii for desired intensity distribution in focal region, such as for the purpose of radial superresolution with high focal depth in optical storage. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The large-insert genomic DNA library is a critical resource for genome-wide genetic dissection of target species. We constructed a high-redundancy bacterial artificial chromosome (BAC) library of a New World monkey species, the black-handed spider monkey

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Amphioxus is a crucial organism for the study of vertebrate evolution. Although a genomic BAC library of Branchiostoma floridae has been constructed, we report here another BAC library construction of its distant relative species Branchiostoma belcheri. The amphioxus BAC library established in present study consists of 45,312 clones arrayed in one hundred and eighteen 384-well plates. The average insert fragment size was 120 kb estimated by Pulsed Field Gel Electrophoresis (PFGE) analysis of 318 randomly selected clones. The representation of the library is about 12 equivalent to the genome, allowing a 99.9995% probability of recovering any specific sequence of interest. We further screened the library with 4 single copied Amphi-Pax genes and identified total of 26 positive clones with average of 6.5 clones for each gene. The result indicates this library is well suited for many applications and should also serve as a useful complemental resource for the scientific community.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We constructed a high redundancy bacterial artificial chromosome library of a seriously endangered Old World Monkey, the Yunnan snub-nosed monkey (Rhinopithecus bieti) from China. This library contains a total of 136 320 BAC clones. The average insert size of BAC clones was estimated to be 148 kb. The percentage of small inserts (50-100 kb) is 2.74%, and only 2.67% non-recombinant clones were observed. Assuming a similar genome size with closely related primate species, the Yunnan snub-nosed monkey BAC library has at least six times the genome coverage. By end sequencing of randomly selected BAC clones, we generated 201 sequence tags for the library. A total of 139 end-sequenced BAC clones were mapped onto the chromosomes of Yunnan snub-nosed monkey by fluorescence in-situ hybridization, demonstrating a high degree of synteny conservation between humans and Yunnan snub-nosed monkeys. Blast search against human genome showed a good correlation between the number of hit clones and the size of the chromosomes, an indication of unbiased chromosomal distribution of the BAC library. This library and the mapped BAC clones will serve as a valuable resource in comparative genomics studies and large-scale genome sequencing of nonhuman primates. The DNA sequence data reported in this paper were deposited in GenBank and assigned the accession number CG891489-CG891703.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

1998 年在西藏墨脱县海拔1000 m 左右地方采到成年雌性环蛇1 号, 系我国新纪录。该蛇全长/ 尾长(mm) 1095/ 112 (尾尖断) 。通身背面黑褐色, 后3/ 4 有由背鳞白色点斑缀成的窄横纹约40 个; 腹面浅黑 色, 每隔3 或4 枚腹鳞有不规则的黄白色横斑。尾背有少数不完整的白色纹, 但尾腹面有7 条很明显的横斑。头 部斑纹与M. Smith (1943 : 410) 描述一致, 可能由于蛇龄较老而不清晰。背鳞通身15 行, 脊鳞略扩大; 腹鳞 233 , 尾下鳞35 (略低于文献记载的44~51 , 可能与尾尖断有关) , 除前端第三、四两枚成单外, 其余均成对。 没有颊鳞; 眶前鳞1 , 眶后鳞2 ; 颞鳞1 + 2 ; 上唇鳞7 (22223 式) ; 下唇鳞7 , 第一对在颏鳞后彼此相接, 前4 对 接前颔片; 前颔片大于后颔片, 后者后半介一小鳞。检查一侧, 除前沟牙及其预备牙外, 没有发现其他上颌齿。