29 resultados para Measurement error models
Resumo:
A new method to measure reciprocal four-port structures, using a 16-term error model, is presented. The measurement is based on 5 two-port calibration standards connected to two of the ports, while the network analyzer is connected to the two remaining ports. Least-squares-fit data reduction techniques are used to lower error sensitivity. The effect of connectors is deembedded using closed-form equations. (C) 2007 Wiley Periodicals, Inc.
Resumo:
As there exist some problems with the previous laser diode (LD) real-time microvibration measurement interferometers, such as low accuracy, correction before every use, etc., in this paper, we propose a new technique to realize the real-time microvibration measurement by using the LD sinusoidal phase-modulating interferometer, analyze the measurement theory and error, and simulate the measurement accuracy. This interferometer utilizes a circuit to process the interference signal in order to obtain the vibration frequency and amplitude of the detective signal, and a computer is not necessary in it. The influence of the varying light intensity and light path difference on the measurement result can be eliminated. This technique is real-time, convenient, fast, and can enhance the measurement accuracy too. Experiments show that the repeatable measurement accuracy is less than 3.37 nm, and this interferometer can be applied to real-time microvibration measurement of the MEMS. (C) 2007 Elsevier GmbH. All rights reserved.
Resumo:
Only the first- order Doppler frequency shift is considered in current laser dual- frequency interferometers; however; the second- order Doppler frequency shift should be considered when the measurement corner cube ( MCC) moves at high velocity or variable velocity because it can cause considerable error. The influence of the second- order Doppler frequency shift on interferometer error is studied in this paper, and a model of the second- order Doppler error is put forward. Moreover, the model has been simulated with both high velocity and variable velocity motion. The simulated results show that the second- order Doppler error is proportional to the velocity of the MCC when it moves with uniform motion and the measured displacement is certain. When the MCC moves with variable motion, the second- order Doppler error concerns not only velocity but also acceleration. When muzzle velocity is zero the second- order Doppler error caused by an acceleration of 0.6g can be up to 2.5 nm in 0.4 s, which is not negligible in nanometric measurement. Moreover, when the muzzle velocity is nonzero, the accelerated motion may result in a greater error and decelerated motion may result in a smaller error.
Resumo:
Based on a long-term ecological monitoring, the present study chose the most dominant benthic macroinvertebrate (Baetis spp.) as target organisms in Xiangxi River, built the habitat suitability models (HSMs) for water depth, current velocity and substrate, respectively, which is the first aquatic organisms model for habitat suitability in the Chinese Mainland with a long-term consecutive in situ measurement. In order to protect the biointegrity and function of the river ecosystem, the theory system of instream environmental flow should be categorized into three hierarchies, namely minimum required instream flow (hydrological level), minimum instream environmental flow (biospecies level), and optimum instream environmental flow (ecosystem level). These three hierarchies of instream environmental flow models were then constructed with the hydrological and weighted usable area (WUA) method. The results show that the minimum required instream flow of Xiangxi River calculated by the Tennant method (10% of the mean annual flow) was 0.615 m(3) s(-1); the minimum instream environmental flow accounted for 19.22% of the mean annual flow (namely 1.182 m(3) s(-1)), which was the damaged river channel. ow in the dry season; and 42.91% of the mean annual flow (namely 2.639 m(3) s(-1)) should be viewed as the optimum instream environmental flow in order to protect the health of the river ecosystem, maintain the instream biodiversity, and reduce the impact of small hydropower stations nearby the Xiangxi River. We recommend that the hydrological and biological methods can help establish better instream environmental. ow models and design best management practices for use in the small hydropower station project. (C) 2008 National Natural Science Foundation of China and Chinese Academy of Sciences. Published by Elsevier Limited and Science in China Press. All rights reserved.
Resumo:
The alternate combinational approach of genetic algorithm and neural network (AGANN) has been presented to correct the systematic error of the density functional theory (DFT) calculation. It treats the DFT as a black box and models the error through external statistical information. As a demonstration, the AGANN method has been applied in the correction of the lattice energies from the DFT calculation for 72 metal halides and hydrides. Through the AGANN correction, the mean absolute value of the relative errors of the calculated lattice energies to the experimental values decreases from 4.93% to 1.20% in the testing set. For comparison, the neural network approach reduces the mean value to 2.56%. And for the common combinational approach of genetic algorithm and neural network, the value drops to 2.15%. The multiple linear regression method almost has no correction effect here.
Resumo:
Qubit measurement by mesoscopic charge detectors has received great interest in the community of mesoscopic transport and solid-state quantum computation, and some controversial issues still remain unresolved. In this work, we revisit the continuous weak measurement of a solid-state qubit by single electron transistors (SETs) in nonlinear-response regime. For two SET models typically used in the literature, we find that the signal-to-noise ratio can violate the universal upper bound "4," which is imposed quantum mechanically on linear-response detectors. This different result can be understood by means of the cross correlation of the detector currents by viewing the two junctions of the single SET as two detectors. Possible limitation of the potential-scattering approach to this result is also discussed.
Resumo:
Formulation of a 16-term error model, based on the four-port ABCD-matrix and voltage and current variables, is outlined. Matrices A, B, C, and D are each 2 x 2 submatrices of the complete 4 x 4 error matrix. The corresponding equations are linear in terms of the error parameters, which simplifies the calibration process. The parallelism with the network analyzer calibration procedures and the requirement of five two-port calibration measurements are stressed. Principles for robust choice of equations are presented. While the formulation is suitable for any network analyzer measurement, it is expected to be a useful alternative for the nonlinear y-parameter approach used in intrinsic semiconductor electrical and noise parameter measurements and parasitics' deembedding.
Resumo:
Hybrid opto-digital joint transform correlator (HODJTC) is effective for image motion measurement, but it is different from the traditional joint transform correlator because it only has one optical transform and the joint power spectrum is directly input into a digital processing unit to compute the image shift. The local cross-correlation image can be directly obtained by adopting a local Fourier transform operator. After the pixel-level location of cross-correlation peak is initially obtained, the up-sampling technique is introduced to relocate the peak in even higher accuracy. With signal-to-noise ratio >= 20 dB, up-sampling factor k >= 10 and the maximum image shift <= 60 pixels, the root-mean-square error of motion measurement accuracy can be controlled below 0.05 pixels.
Resumo:
A Penning trap, which can measure the atomic masses with the highest precision, is one of the most important facilities in nuclear physics research nowadays. The precision mass data play an important role in the studies of nuclear models, mass formulas, nuclear synthesis processes in the nuclear astrophysics, symmetries of the weak interaction and the conserved vector current (CVC) hypothesis. The status of high precision mass measurement around the world, the basic principle of Penning trap and the basic information about the LPT (Lanzhou Penning Trap) are introduced.
Resumo:
A dynamic measurement system was developed by the Institute of Modern Physics (IMP) for the dipole prototype of Rapid Cycle Synchrotron (RCS) of China Spallation Neutron Source (CSNS). The repetition frequency of RCS is 25 Hz. The probe is a moving arc searching-coil, and the data acquisition system is based on the dynamic analysis modular of National Instrument. To get the error of high order harmonics of the field at basic frequency, the hardware integrator is replaced by a high speed ADC with software filter and integrator. A series of harmonic coefficients of field are used to express the varieties of dynamic fields in space and time simultaneously. The measurement system has been tested in Institute of High Energy Physics (IHEP), and the property of the dipole prototype of RCS has been measured. Some measurement results and the repeatability of system are illustrated in this paper.
Resumo:
The remote sensing based Production Efficiency Models (PEMs), springs from the concept of "Light Use Efficiency" and has been applied more and more in estimating terrestrial Net Primary Productivity (NPP) regionally and globally. However, global NPP estimates vary greatly among different models in different data sources and handling methods. Because direct observation or measurement of NPP is unavailable at global scale, the precision and reliability of the models cannot be guaranteed. Though, there are ways to improve the accuracy of the models from input parameters. In this study, five remote sensing based PEMs have been compared: CASA, GLO-PEM, TURC, SDBM and VPM. We divided input parameters into three categories, and analyzed the uncertainty of (1) vegetation distribution, (2) fraction of photosynthetically active radiation absorbed by the canopy (fPAR) and (3) light use efficiency (e). Ground measurements of Hulunbeier typical grassland and meteorology measurements were introduced for accuracy evaluation. Results show that a real-time, more accurate vegetation distribution could significantly affect the accuracy of the models, since it's applied directly or indirectly in all models and affects other parameters simultaneously. Higher spatial and spectral resolution remote sensing data may reduce uncertainty of fPAR up to 51.3%, which is essential to improve model accuracy.
Resumo:
Sea surface salinity is a key physical parameter in ocean science. It is important in the ocean remote sensing to retrieve sea surface salinity by the microwave probe technology. Based on the in situ measurement data and remote sensing data of the Yellow Sea, we have built a new empirical model in this paper, which can be used to retrieve sea surface salinity of the Yellow Sea by means of the brightness temperature of the sea water at L-band. In this model, the influence of the roughness of the sea surface is considered, and the retrieved result is in good agreement with the in situ measurement data, where the mean absolute error of the retrieved sea surface salinity is about 0.288 psu. This result shows that our model has greater retrieval precision compared with similar models.